Calibration curve

Decent Essays
Improved Essays
Superior Essays
Great Essays
Brilliant Essays
    Page 11 of 20 - About 198 Essays
  • Great Essays

    showed us the sensitivity of the LVDT. We then took the voltages that were given at different displacements by the LVDT during the calibration. Each of these were converted into position by reformatting equation 1 to solve for position. The ‘Normalizing’ was done by saying that when the block was pushed up against the fixed plate that it was equal to zero. After calibration was completed and the calculations were completed we moved on to the drop test. Each of the three test were executed by…

    • 2010 Words
    • 9 Pages
    Great Essays
  • Great Essays

    Preformulation Study Preparation of calibration curve of Amoxicillin trihydrate [51,53,76] Preparation of stock for Hydrochloric acid Stock solution in 0.1N Hydrochloric acid (0.1N HCl): 10 mg of Amoxicillin was accurately weighed and transferred into 10 ml volumetric flask. It was dissolved and diluted to volume make up to mark with 0.1N HCl to give stock solution containing 1000 µg/ml, after than 1ml take to from 1000 µg/ml and dilute to volume make up to mark of 10ml volumetric flask with…

    • 2932 Words
    • 12 Pages
    Great Essays
  • Great Essays

    UV U3010) at 290 nm peak absorbency to obtain the respective absorbance values. The wavelength at 290 nm was determined as the peak absorbency wavelength as maximum absorbency at this particular wavelength was observed. The equation of the linear curve shown in Table 1 and Figure 1 produced with the three points of different concentrations was used to quantify the concentrations of gentamicin in the withdrawn sample solutions. Drug release profiles for the different sets of implants up to 14…

    • 1717 Words
    • 7 Pages
    Great Essays
  • Great Essays

    compare expected mortality risk with observed mortality rate. Receiver operating characteristics (ROC) curve analysis was done and standardized mortality ratio was calculated. PIM2 Index validation was performed by use of Hosmer and Lemeshow goodness-of-fit test. Results : Two hundred patients were included in this study. The model fit was achieved adequately (P value=0.741). The area under the ROC curve was 0.773 (95%CI: 0.65-0.92) and standardized mortality ratio was 1.08.PIM2 calibrated well…

    • 1813 Words
    • 8 Pages
    Great Essays
  • Decent Essays

    Pestle Analysis Lab

    • 310 Words
    • 2 Pages

    If there was a difference between the two, it would imply that there are other matrices affect the Roundup. When looking at figure 2 and figure 4, the calibration curves are similar. This can be seen when looking at the dilution 0.2% where both graphs are above an absorbance of 1. Also, the relative deviations are small. With both the serial and stock dilution, the pH was the same. The purpose of determining…

    • 310 Words
    • 2 Pages
    Decent Essays
  • Improved Essays

    Nowadays, caffeine becomes more and more familiar to human. People intake different amount of caffeine from different foods. It becomes part of human’s daily routine. https://www.google.com/search?q=caffeine&espv=2&biw=706&bih=567&source=lnms&tbm=isch&sa=X&ved=0ahUKEwiVmOWn1sHMAhXGuBoKHTGYAbsQ_AUIBigB#imgrc=ya-sLhS2Ae9x2M%3A Caffeine (C8H10 N4O2) a substance that has a bitter taste and is usually found in coffee, tea, soft drinks, chocolate, kola nuts, and certain medicines. It affects body’s…

    • 918 Words
    • 4 Pages
    Improved Essays
  • Improved Essays

    Hplc Analysis

    • 1397 Words
    • 6 Pages

    A calibration curve for the total phenolic content of Gallic acid with concentration of 20, 40, 60, 80 and 100 μg/mL shown in Figure 4.4 and the results were expressed as gallic acid equivalents (GAE)/g of samples. Figure 4.4: Standard curve of Gallic acid. From the standard curve, an equation was obtained from the straight line, where y = 0.0061x - 0.0871 (R2= 0.9898). Table 4.10 shows the…

    • 1397 Words
    • 6 Pages
    Improved Essays
  • Great Essays

    While it may take time to prepare the standard solutions of known concentration to develop the calibration curve for the spectrophotometer before testing a filtrate, the equations involved in determining the amount of a compound necessary for preparing solutions of specific volume and concentration are simple and do not take a large amount of time to complete…

    • 1772 Words
    • 8 Pages
    Great Essays
  • Superior Essays

    Water Hardness Lab Report

    • 3577 Words
    • 15 Pages

    James Apostolico November 6, 2014 The Chemistry of Natural Waters Chemistry 111 Section: 005 Kareem Ali, Dima Alfawaz Stephanie Le Clair Introduction Water hardness is a way of defining the quality of water based upon the amount of Ca2+ and Mg2+ions that the sample contains.1 Water mostly becomes hard by flowing over weathering rocks which release these ions into the water. These released ions dissolve in water and then react with various elements, ions and compounds that…

    • 3577 Words
    • 15 Pages
    Superior Essays
  • Great Essays

    Xm Newton Research Paper

    • 2558 Words
    • 11 Pages

    (1) Gunzip ODF/*.gz : To unzip data fies. (2) cifbuild: Calibration information from the Calibration Access Layer is necessary for many SAS tasks. Relevant accessed from the set of current Calibration File (CCF) data using a CCF Index File (CIF). CCF files are directly downloaded from the SOC website. A CIF is included in the pipeline products (*CALIND*). For the updated version…

    • 2558 Words
    • 11 Pages
    Great Essays
  • Page 1 8 9 10 11 12 13 14 15 20