• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/98

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

98 Cards in this Set

  • Front
  • Back

An _____ is a type of circle that is elongated in one direction.

Ellipse

The length, width, and height of a feature on a print are defined by the _________.

Size dimensions

______ and ______ are the two basic types of dimensions found on construction prints.

Size, Location

A _________ is a change to the prints or specifications after the bids are set and the project has started.

Change order

Symbols are used on drawings to save the space and to ______________.

Simplify and standardized notation

In the United States, ________ is responsible for the standardization of symbols.

ANSI

The difference between the flow direction arrow for hydraulic prints and pneumatic prints is…

Hydraulic arrows are darkened in, pneumatic arrows are only outlined.

________ is included in the NEC in the form of informal notes.

Explanatory material.

The phrase, “shall not be required”, is a phrase used in the NEC to denote a __________.

Permissive rule

An accessory such as a locknut, bushing, or other part of a wiring system that is intended primarily to perform a mechanical, rather than an electrical function, by definition, is considered to be a _______.

Fitting

The conductors and equipment required or permitted by this Code shall be acceptable only if ________.

Approved

In judging electrical equipment, compliance with international standards is generally not considered mandatory in the _____________.

Evaluation of equipment

_______ when installed in a raceway, is permitted to be a solid conductor.

10 AWG

The NEC indicates that underground conduits are considered to be located in a ____ location.

Wet

Nonmetallic-sheathed cable wiring is generally used in a ____ location.

Dry

______ requirements refer to the minimum and maximum amount of pressure in inch-pounds that can or needs to be applied to the screw terminal on a wiring device to safely and properly secure the conductor to the device terminal.

Torque

Straight-blade and locking-blade wiring devices are generally used in the _____ configuration system.

NEMA

Generally, a minimum rating of _______ is required for a receptacle device.

15 amperes

A non-grounding type receptacle shall be permitted to be replaced with a grounding-type receptacle where supplied through a ______.

GFCI

Receptacles incorporating an isolated grounding conductor connection intended for the reduction of electrical noise (electromagnetic interference) as permitted in NEC 250.146(D) shall be identified by ___________.

An orange triangle located on the face of the receptacle.

_____ or _____ would be the receptacle rating for two or more receptacles connected to a branch circuit rated at 20 amperes.

15 A or 20 A

General use dimmer switches shall be used to control only __________________ unless listed for the control of other loads and installed accordingly.

Permanently installed incandescent luminaires

Unless listed and marked for other than single-circuit use, multi-pole switches are for use only on _______.

Single circuits

Examples of explanatory material include __________________________.

References to other standards, references to other sections of the NEC and informational notes.

_______ is the title of Article 230 in the NEC.

Services

A ______ is defined as the conductors and equipment connecting the serving utility to the wiring system of the premises served.

Service

The maximum demand for a 10-kilowatt household electrical range is ______.

8 kw

Article ____ in Chapter 3 of the NEC covers general requirements of wiring methods.

300

Raceways installed under metal corrugated roof decking must be supported so that the top of the raceway is ______ from the roof decking.

1-1/2”

The interior raceway on the outside of a building in a wet location is __________.

Also a wet location

Each vented cell of a storage battery shall be equipped with a ________ designed to prevent destruction of the cell due to ignition of gases within the cell by an external speak or flame.

Flame arrestor

A new RV park has 100 RV sites. ____ sites must be served by a 30-ampere, 125-volt receptacle.

70

An area within a facility that is designated as requiring critical operations power is called a ___________.

Designated critical operations area

An optical fiber cable without current-carrying electrical conductors is defined as a ______ optical fiber cable.

Composite

The kind of conductors does Table C.3(A) of Annex C applies to is _______.

Compact

__________ prevents electrons from being pulled into the nucleus of an atom.

Centrifugal force

The outer ring (shell) of an atom is cannot hold more than __ electrons at any one time.

8

_______ particle is found in the orbital shells of an atom.

Electron

The only electrons available to participate in electrical current now are those in ________.

Outer shells

There is __ electron contained in the valence (outer) shell of a copper atom.

1

The chemical process used in electroplating is called _______.

Electrolysis

As the resistance of an incandescent lamp filament is increased, its wattage rating _______.

Decreases

Heat is produced in an electrical circuit due to the amount of ___________.

Current flowing through the circuit

Current flow in electrical components should be traced from _______ to _______.

Negative, positive

The unit of electrical resistance is the ____.

Ohm

A multimeter should away be placed on the ______ scale before taking the voltage reading in a circuit.

Highest

1,000 volts minus 999 volts equals ________.

1,000 millivolts

The least complicated test instrument for identifying if a receptacle is wired properly and energized is a _________.

Receptacle tester

The ________ is a test instrument that is used to test for insulation breakdown.

Megohmeter

It is clear to most people who have worked in the construction trades that a dirty job site is ___________.

A dangerous job site

There are two basic causes of accidents, _______ and _______.

Unsafe conditions and unsafe acts

Leaning a step ladder against a wall to service a lamp ballast is an ________ with respect to ladder usage.

Unsafe act

_______ is not of the fort types of concrete anchors.

Carbide

__________ does not determine the length of an anchor.

Fixture hole size

When fastening a heavy item to brick, what is the most important step?

Anchor the item to the main structure.

_________ is a laser tool that works best when at a distance of 100 feet or more.

Rotary laser

An approved type of pulling rope must be used when pulling conductors in PVC conduit.

True

There are several factors which determine the severity of an electrical shock. The __________ is not necessarily one of those factors.

Level of wattage contacted

The following reactions best describe a current of ___________: extreme pain, respiratory arrest, severe muscular contractions: death is possible.

100 milliamperes

________ or ________ should be used to temporarily splice two ropes of different diameters.

Single, double sheet bend

When signaling a France operator, you should make everyone else in the area is ________ before signaling to lift.

Clear of the load

______ is the best electrical conductor.

Silver

Conductors installed in wet locations require insulation that protects the conductors from ______________.

Continuous exposure to moisture

The _______ is the unit of area used to measure the cross sectional area of wire.

Circular mil

Convert the following value: 40 mA = _______

40,000 microamps

Convert the following value: 212 mA = ______

0.212 amps

The square meter is a unit of measurement of _____.

Area

The meter is a unit of measure of _____.

Length

The adoption of the _____ system will allow American made products to be immediately and openly received on all world markets without the “units-of-measure” barriers they face today.

Metric

A ______ penetration only passes through one side of a fire-resistive wall assembly.

Membrane

An alcohol and drug abuse center would be classified as a Group ________ classification.

I Institutional

_________ would be classified as an emergency power load.

Elevator car lighting

The purpose of a low-voltage bracket is…

To aid in maintaining proper cable bend radius. To connect flexible raceways and to mount low voltage plates to.

A _______ is not connected to a residential structured cabling system.

Doorbell

____ is not a type of optical fiber raceway.

PLTC

_____ is currently working on a tag that would be acceptable for identifying a cable intended for future use.

NECA

In a residential installation, a minimum future proofing scheme would be a ___________.

2” raceway from the distribution box to the attic

A ________ is not one of the features of a concrete pour, non-metallic floor box.

Built-in divider

A beam clamp would be used with ______, ______, and ______.

Hangers, bridle rings, drop rods

________ is used for drilling holes through masonry material.

Star drill

_______ or _______ is the safest type of wrench to use for breaking frozen fasteners.

Box end, socket wrench

It is clear to most people who have worked in the construction trades that a dirty job site is a __________.

Dangerous job site

__________ is a good, safe procedure when cutting and threading conduit.

Remove rings and other jewelry

________ is considered an unsafe condition in the electrical trades.

Painted wooden ladder

There are four types of fasteners; ________ is not one of them.

Carbide

When fastening a heavy item to brick, ___________ is the most important step.

Anchor the item to the main structure

The diameter of the hole in the base material when installing a masonry fastener is the most important thing.

True.

Electricity has long been recognized as a ______ workplace hazard, exposing employees to electric shock, electrocution, burns, fires, and explosions.

Serious

The following reactions best describe a current of _________: extreme pain, respiratory arrest, severe muscular contractions, death is possible.

100 milliamperes

_______ is not a common physical reaction from an electrical shock.

Bleeding

The best method of stripping conductors for splices or terminations is use an __________.

Appropriate stripping tool

There are no shortcuts to knowledge. For the successful completion of this program, requires grasping a tremendous amount of knowledge.

Okay

There are no shortcuts to knowledge. For the successful completion of this program, requires grasping a tremendous amount of knowledge.

Okay

This apprenticeship program is designed to mold you into a competent, qualified craftsman with a well-shaped and defined ______, knowledge and attitude.

Skills

The foundation of what was to become the IBEW was formed in ____ in the city of St. Louis.

1890

The role of a NECA Chapter Manager is to ___________________.

Act as a liaison between NECA Contractors and the Local Union.

You report an incidence of sexual harassment _________.

Immediately

__________ on the job is a major reason that job tasks cannot be performed in a timely manner.

Absenteeism