• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/57

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

57 Cards in this Set

  • Front
  • Back

What features of the BISMP will no longer be found in the AISMP security pit control station

Secondary door raise, lower, off switch and an access shaft light switch

Opening the primary door is only possible if the

Vault door is removed and the lock bolt is retracted

What BISMP seconder door top operation would not be normally performed by technician on a AISMP secondary door top

Manually retracting the lock bolts

What must be verified before the secondary door can be secured

Both combination locks are operational

Upon entering the security pin retraction window of time, the SARC commanded operations that must occur to lower the secondary door include retracting the

Actuator locking bar and locking bolts

What MSB maintained equipment item is required to penetrate in a AISMP launch facility but not BISMP

Site activation remote control

Entering the electro mechanical actuator system into enhanced maintenance mode is achieved by setting the mode switch on the

SDCA to maintenance and the EMA gear Box safety pin is engaged

Which secondary door control assembly panel houses timer circuits that provide control of the site penetration delay timer and security pin retraction timer

Back

At a BISMP launch facility, it is important to switch the secondary control switch in the secondary pit control station to off before entering the launcher equipment room because the

EMLA selector switch would be ineffective

Which major electro mechanical actuator system component is partially charged by the lowering of the secondary door and supplements launch facility commercial power to raise the secondary door

Energy storage system

Which major electro mechanical actuator system component may use commercial or auxiliary power to run the EMA

Motor drive cabinet

The hydraulic ram assist with opening the launcher closure door

Forcing the lock pin down

The purpose for making reference points along the launcher closure rail is to

Permit recovery strap installation to the cable pin underneath the LC door to stop it at certain points

During launch facility forced entry, and electro mechanical team begins repair actions on the fault combination lock assembly after the

SCS is installed and the launcher equipment room penetration procedures have been completed

What would be reported at the launch control center if there was an attempt to unlock the security pit vault door

Inner zone alarm

What wing 1 launch facility security system feature does not exist at wing 3 or wing 5 launch facility

Outer zone switch loop

How many alternating current generators does the MAF motor generator have

2

White wing 3 and when 5 launch control center has no more than 10 storage batteries connected in series parallel

Primary LCC

The battery charger for the missile alert facility storage batteries is contained in the

Power supply group

How are the storage batteries configured at all wing one launch control centers

8 pairs of batteries connected in series parallel

What power output does the diesel-electric unit produce at a wing 3 and when 5 launch facility in the event of a commercial power failure

120/208 VAC, 3 phase, 60 hertz only

What component installed on the MAF motor generator is not installed on the launch facility motor generator

60 Hz AC generator

When the distribution Box connects ordinance devices in order to test loads, this means the

Safety control switch key is installed

The launch control centers interconnecting Box provides an interface between the

Electrical surge arresters and electronic equipment

What components of an electrical surge arestor module limit the current entering the system during a surge condition

20 ohm resistors

What feature prevents the cables from being damaged when the shock mounted floor moves

Shock loops

What launch facility interconnecting Box component device will only be used in the LF it's designed for due to its site specific signal distribution

Sorting plug

What device in a launch facility interconnecting Box protects against undesirable signals which may have been picked up on the hardened intersite cabling system cables

Pulse suppressor assembly

Which electrical filter assembly located outside the electrical surge arrester vault protects the security lines

F-1343/GSW-13 (urd 10443)

Electro magnetic interface filtering for the AISMP secondary door is through

14 electrical surge arrester modules

Which weapon system control console component will provide an indicator for a fire alarm

Auxiliary alarm panel

What processes the commands and provides reports of missile and ground equipment status during ground operations

Digital computer unit

What launch facility component contains digital data line scanning, seize and lock out circuits

Message processor drawer

What launch facility drawer would you connect a controller monitor to in order to accomplish tape load procedures

Guidance and control coupler

What launch facility drawer contains electro magnetic pulse sensing circuitry

Ultra high frequency receiver

Under what conditions will a launch control center register another launch control center as being down

Failing to transmit proper operational status integrations for 240 seconds

What provides the mechanism for encrypting and decrypting messages in the command and control system

Secure data unit

What is performed if a launch facility does not register a valid encrypted operational status integration for 240 seconds

Airborne launch control center command entry

About how many gallons of coolant does the tank of the guidance section liquid cooler store

7

In addition to a ground maintenance reply 25, what else will be reported to the launch control center when the missile guiding set reaches 80 ゚F

Nothing else

Aside from hydraulic lines, what is the last component in the guidance section liquid cooler the coolant flows through before entering the missile guidance set

Control valve

A decrease in the thermostat or resistance would indicate a

Temperature increase in the missile guidance set

Doing power applied check out, what action, if any, is required if the red no go indicator on the electronic control amplifier illuminates

Shut down the missile guidance set manually

What minute man system monitors missile functional performance, provides signals and ground power, maintains the liquid coolant, and the environmental control required to sustain missile operation until launch

Operational ground equipment

Which of the following is the controller monitor not required for aero space vehicle equipment start up

Reentry system maintenance is accomplished

During the digital computer unit memory loading, where is the program data contained before it is loaded into the DCU memory

Magnetic tape cartridge

Why are operational gound equipment and aerospace vehicle equipment start up normally not required during code change loading

Guidance and control system is already in strategic alert

Digital computer unit program loading requires the use of a cartridge tape unit, controller monitor,

Cable set, and LFLC

If an error indicator on condition and output status of the cartridge tape unit is parity error stop, which of the following will be unsuccessful

Conditioning cycle

The tape ID block tells the operator that the tape cartridge is for a particular

Launch facility

How does the cartridge tape unit determine when the end of file is reached

A tape mark is detected

The computer memory security check number consists of how many digits

Eight

When does the digital computer unit exit into strategical alert

Completion of the alignment mode

What indicates the battery has already been turned on and the static random access memory contains stored data during digital computer unit initialization sequence

A battery flag discrete set false

What are the 2 alignment modes available durring ground initialization in the minuteman system

Initial and restart

What is the launch readiness mode of the guidance control set

Strategic alert

Who is required to remove or install the operational keying variable

Authorized code handling team