What are three camp layout considerations?
|
1. Key Terrain Features KOCOA
2. Security/ Defensive Posture 3. Health and Sanitation |
|
What does the acronym KOCOA means?
|
Key Terrain Features, Observation and Fields of Fire, Cover and Concealment, Obstacles (Man made or Natural), Avenues of approach.
|
|
Define Cover and Concealment in KOCOA?
|
Cover and Concealment in a Camp Layout is important for Camp Security, Protections and Safety.
|
|
Camp facilities and utilities should be dispersed by how many meters?
|
35
|
|
In a camp the heads should be at least how far from a natural water source?
|
100 yds
|
|
How many meters apart should utilities be from a natural water sources?
|
100 m
|
|
How far apart should the TOC and Ant Farm be?
|
100 m
|
|
What does ECP stands for?
|
Entry Control Point.
|
|
What are the three types of ECP’s for Defensive Posture.
|
Serpentine, Bunker and Observation.
|
|
How many yards should Garbage Disposal/Burn Pit area be from a natural water source?
|
100yds
|
|
What are the dimension specifications for a camp burn pit?
|
4’X 4’ hole 4 feet deep per 100 Troops per day.
|
|
What are the three considerations for setting up Generators?
|
Sheltered, Grounded and Contained.
|
|
What is the diameter size of a grounding rod and at least how deep should it be buried in the ground?
|
Diameter is 5/8” and least 8’ Deep.
|
|
What does ROWPU stand for?
|
Reverse Osmosis Water Purification Unit
|
|
ROWPU site selection must be how far upstream of a usable water source?
|
75 ft
|
|
A ROWPU is powered by what?
|
30 KW generator
|
|
A ROWPU can purify how many gallons per hour of soiled water / salt water?
|
600 gal soiled
400 gal salt |
|
The facilities and heads should be separated by how many yards?
|
100 yds
|
|
Whee should the leach gray water be positioned?
|
Where it goes down hill into unused area
|
|
Burn pits should be how far away from the mess.
|
30 yds
|
|
What are some examples of camp essentials?
|
TOC, ECP, Barriers, Laundry, Armory, Galley, Supply, Berthing, Water supply
|
|
What is the purpose of Operator Logs?
|
Kept on certain equipment like generators to record continuous data on equipment history and performance.
|
|
What are the rules for Sheltered Generators?
|
Sandbags overlap perimeter of the unit allowing room for air flow and maintenance. Stack them half as high as generator while leaving opening for refueling and ventilation.
|
|
What are the rules for Grounded Generators?
|
3 Section, 9' rods 5/8" diameter, be buried at least 8' deep, one section at a time, using 5 AWG stranded copper wire.
|
|
What are the rules for a contained Generator?
|
4 wall berm, 6" wider than the unit on each side, lines with nonporous material to capture oi or fuel leaks.
|
|
What is the max allowed incline or decline of a ROWPU?
|
15 degrees
|
|
Who will conduct routine inspections an scheduled maintenance on Camp Support Equipment?
|
CSSD Personnel
|