Each plumbing fixture, except for those having integral traps, shall be ________________.
|
seperately trapped by an approved liquid seal trap
|
|
One trap may serve a set of not more than ______________ single compartment sinks.
|
three
|
|
A food waste disposal unit installed in restaurant, commercial, or industrial sinks ____________.
|
must be individually trapped
|
|
The maximum vertical distance for a tailpiece allowed between a fixture and the trap weir is _________________ inches.
|
24
|
|
Each plumbing fixture trap shall be protected against siphonage and back pressure by a ________________.
|
vent pipe
|
|
A trap arm smaller than 3 inches may change direction without a cleanout if the change in direction does not exceed ________________ degrees.
|
90
|
|
The vent pipe opening from a soil or waste pipe, except for water closets and similar fixtures __________________.
|
shall not be below the weir of the trap
|
|
The maximum horizontal distance a trap arm shall be from the trap to the vent opening for a 2 inch trap is ___________ feet.
|
5
|
|
Each trap, except for traps within interceptors or similar devices, __________________ .
|
shall be self cleaning
|
|
No more than _______________ approved slip joint fitting(s) may be used on the outlet side of a trap.
|
one
|
|
The size of the trap connected to a fixture shall be sufficient to drain the fixture rapidly, but
|
cannot be smaller than the fixture drain nor can it be more than one size larger than the fixture drain
|
|
No trap shall be used that __________________.
|
depends on movable parts, has concealed interior partitions, or is classified S or Bell trap
|
|
Each fixture trap shall have a water seal _________________.
|
between 2 and 4 inches
|
|
Floor drains shall connect into a trap so constructed that it can be _______________.
|
readily cleaned
|
|
Floor drains or similar traps directly connected to the drainage system and subject to infrequent use shall be __________________________.
|
protected with an accessible trap seal primer, except when not deemed necessary by the Authority Having Jurisdiction
|
|
Each building trap when installed shall be provided with __________________.
|
a cleanout and a relieving vent or fresh air intake on the inlet side of the trap
|
|
Interceptors shall be provided when, in the judgement of the Authority Having Jurisdiction, they are necessary for the proper handling of liquid wastes containing ________________.
|
sand and/or solids
|
|
Interceptors for sand and similar heavy solids shall have a water seal of not less than _______________ inches.
|
10
|
|
Interceptors shall _____________________.
|
be properly vented and covers that are readily accessible for service and maintenance
|
|
Every public or private wash rack and floor or slab used for cleaning machinery or machine parts shall ______________________.
|
be protected from storm and surface water and drain or discharge into an approved interceptor
|
|
Laundry equipment that does not have integral strainers shall discharge into an interceptor having a wire basket or similar device that will prevent the passing of solids ____________________ inch or larger in maximum dimension.
|
1/2
|
|
The Authority Having Jurisdiction had mandated grease pretreatment for the following fixtures: four non-emergency floor drains, two commercial food prep sinks, one mop sink with a 3 inch trap, and two dishwashers discharging 20 gpm each. The minimum size gravity grease interceptor in gallons should be ___________________.
|
1,000
|
|
Each plumbing fixture connected to a type A and B hydromechanical grease interceptor shall be provided with a ____________________.
|
flow control device
|
|
Each fixture discharging into a gravity grease interceptor shall be _______________________.
|
individually trapped and vented
|
|
The total capacity in gallons of fixtures discharging into any hydromechanical grease interceptor shall not exceed _______________ times the certified gpm flow rate.
|
2 -1/2
|
|
Sand interceptors shall be required ___________________________.
|
with heavy discharge or when the AHJ deems it so
|
|
The sand interceptor shall have a minimum dimension of _________________ square feet for the net free opening of the inlet section and a minimum depth under the invert of the outlet pipe of _______________ feet.
|
2, 2
|
|
Sand and similar interceptors shall have a water seal of not less than _____ inches.
|
6
|
|
All repair and gas stations with grease racks or grease pits and all factories that have oily and/or flammable wastes shall be provided with an oil or flammable liquid interceptor that shall ___________________________.
|
be connected to all necessary floor drains and independently vented with a vent not less than 2 inches
|
|
Interceptors not rated by the manufacturer shall have a depth of not less than _______________ feet below invert of the discharge drain and an outlet opening with not less than a _______________ inch water seal.
|
2, 18
|
|
If the AHJ determines that a grease interceptor is not being properly cleaned, the AHJ has the authority to mandate a _________________________________.
|
maintenance program
|
|
A ________________________ shall be installed downstream of hydromechanical grease interceptor in accordance with the requrements of this code.
|
vent
|
|
Gravity grease interceptors shall not be installed in any part of the building where ________________________.
|
food is handled
|
|
The volume of the gravity interceptor shall be determined by using _______________.
|
Table 1014.3.6
|
|
Gravity grease interceptors shall be placed as close as practical to the _______________.
|
fixture they serve
|
|
It is rcommended that a ______________ be located at the outlet end of all gravity grease interceptors.
|
sample box
|
|
Abandoned grease interceptors shall be _____________ and _______________ as required for abandoned sewers and sewage disposal facilities.
|
pumped, filled
|
|
Water closets and urinals shall _____________ into or through a grease interceptor.
|
not drain
|
|
Listed ____________ may be used to connect listed metal tubing traps.
|
plastic adapters
|
|
Grease interceptors shall at all times be _____________ for inspection, cleaning, and removal of grease.
|
easily accessible
|