3.6.1 Containment Above the Line |
Applicability: MODES 1,2,3, and 4 |
|
What makes to Containment OPERABLE?
|
Limiting Leakage to = 1.0 La |
|
TSAC 3.6.1.A Containment inoperable |
Completion time: 1Hour |
|
TSAC 3.6.1.B Required Action and associated completion time not met |
Completion Time: 6 hours B.2 Be in Mode 5 Completion Time : 36 hours |
|
Above the Line |
Applicability: Modes 1,2,3, and 4 NOTES 1. Entry and Exit is permissible to perform repairs on the affected air lock components 2. Seperate entry conditions entry is allowed for each air lock 3. Enter applicable conditions and Required actions of LCO 3.6.1 Containment when air lock leakage results in exceeding the overall containment Leakage rate. |
|
What makes Containment Air Locks OPERABLE?
|
Interlock, leakage |
|
TSAC 3.6.2.A one or more containment airlocks with one bulkhead inoperable
|
A.1 Verify the bulkhead door and equalizing valve are closed on the OPERABLE bulkhead in the affected airlock Completion time: 1Hour A.2 Lock the bulkhead door and equalizing valve closed on the OPERABLE bulkhead in the affected air lock. Completion time: 24 hours A.3 Verify the bulkhead door and equalizing valve on the OPERABLE bulkhead in the affected airlock are locked closed. Completion Time: Once Per 31 days |
|
TSAC 3.6.2.B One or more containment air locks with containment airlock interlock mechanism inoperable.
|
Completion time: 1 hour B.2 Lock the bulkhead door and equalizing valve closed on the OPERABLE bulkhead in the affected air lock. Completion time: 24 hours B.3 Verify the bulkhead door and equalizing valve on the OPERABLE bulkhead in the affected airlock are locked closed. Completion Time: Once Per 31 days |
|
TSAC 3.6.2.C One or more containment air locks inoperable for reasons other than Condition A or B
|
Completion time: Immediately c.2 verify a bulkhead door and associated equalizing valve are closed in the affected airlock. Completion time: 1 hour C.3 Restore Air lock to OPERABLE status Completion time: 36 hours |
|
TSAC 3.6.2.D Required Action and associated completion time not met.
|
Completion Time: 6 hours D.2 Be in MODE 5 Completion time: 36 hours |