• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/13

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

13 Cards in this Set

  • Front
  • Back

Define Safety Limits

Limits upon important process variables that are found necessary to reasonable protect the integrity of certain physical barriers that guard against uncontrolled release of radioactivity.



Limited Safety System Settings (LSSS)

Settings for automatic protective devices related to those variables having significant safety functions.





-Scram Settings, (0.55W + 67%)


-IRM Range 9 or lower <12%, Range 10 <38.4%.


-High Pressure 1080 psi


-Low Level 53"


-Low-Low Level 5"


-MSIV Closure 850# with mode in Run or S/U and IRM Range 10.


-MSIV Closure 10% of closure from full open.


-Generator load reject > 45% (833 MWth)


-TSV Closure >45%


-Safety Valve Setpoints: (3) 1218, (2) 1227, (2) 1236, (1) 1245, (1) 1254


Limiting Condition of Operation (LCO)

The lowest functional capability or performance levels of equipment required for safe operation of the facility.

Cold Shutdown (Mode)

Mode switch in SHUTDOWNor REFUEL (or STARTUP for SDM testing), no core alterations in progress, andcoolant temperature < 212⁰F

Hot Shutdown (Mode)

Mode switch in SHUTDOWN (or REFUEL for pressuretesting, scram timing, or scram recovery), no core alterations in progress, andcoolant temperature > 212⁰F

Refueling (Mode)

Mode switch in REFUEL,coolant temp < 212⁰F, no more than one control rod withdrawn

Power Operating (Mode)

Mode switch in STARTUP or RUN, Reactor is critical or may become critical due to control rod withdrawal.

Major Maintenance

No fuel in the Reactor

Core Alteration

Addition,removal, or relocation of fuel or controls (rods) in the Reactor.




Control rodmovement with the CRD system is NOTconsidered to be a core alteration.

Identified Leakage

Leakage into closed systems that are captured, flow metered, and conducted to a sump or collecting tank OR leakage into the primary containment atmosphere from sources that are both specifically located and known NOT to be from a through-wall crack in the piping within the reactor coolant pressure boundary

Unidentified Leakage

Anything other that Identifiedleakage

Safety Limits

-Reactor Pressure > 700# and Core Flow > 10%, MCPR < SLCPR is a violation.




-Reactor Pressure < 700# or Core Flow < 10%, Reactor Power Shall Not Exceed 25%.




-Neutron Flux shall not exceed its cram setting for >1.5 seconds.

If a safety limit is exceeded....

Shutdown the reactor, make 1 hour NRC notification per 10CFR50.72, submit LER to NRC within 30 days per10CFR50.73, and NRC permission is required to resume operations (startup).