Which zone of damage will there be complete destruction? |
Primary zone |
|
What are the zones of destruction? |
- Primary - Secondary - Remote |
|
A waste paper basket is burning, what class of fire is it? |
Alpha |
|
In which situation would Hands To Emergency Stations be piped? - Large machinery space fire - Multiple replenishment at sea - Entering or leaving a narrow channel - Incoming enemy aircraft |
Large machinery space fire |
|
On a frigate in state Z, condition 1. You want an X opening. Where do you get permission from? |
HQ1 |
|
What is the primary CBRNDC communication circuit called? |
CBRNDC Open line |
|
What drill would be carried out upon hearing the chemical alarm? |
Immediate action drill |
|
Heat can be transferred through metal bulkheads by? |
Conduction |
|
In peace time/harbour time who is responsible for watertight integrity? |
OOD |
|
Where would you find emergency stations duty laid down? |
Ships watch and station bill |
|
What is the main purpose of leak stopping? |
Reduce flow of water to the rate pumps can handle |
|
What does H2S stand for? |
Hydrogen sulphide |
|
What is the duration of an EEBD? |
10 min |
|
How long does a dry powder extinguisher last for? |
20 sec |
|
Which pump is not intrinsically safe? |
Yanmar |
|
What is the primary use of a Britton Marine FSP 36? |
Emergency fire pump |
|
What colour will the one colour detector paper turn when contaminated? |
Navy blue spotting |
|
State 2 shoring tools used in the RNZN |
- Gunter batten - 10lb maul - 2lb hammer - Crosscut saw |
|
Name 3 recognised leak stopping devices |
- splinter box - pipe clamps - wedges - GRP dome |
|
What actions are to be taken upon hearing "close all red openings" |
- close all red openings in your vicinity - remain until further action piped by command |
|
Seven rules of shoring |
- always cut remote scene - always set a shoring watch - always use a Gunter batten - always shore against structure - never pre erect - never pre cut - never use shoring timber less than 30 times it's minimum width |
|
The ship is in state 1, condition Z, hands are at action stations. The ship has been hit by enemy fire. A blanket search has been initiated. Two things must be done prior to opening hatch/door. What are they and what do you do? |
Fire; check with the back of your hand, don't open if fire is suspected. Flood; crack the hatch slowly, look listen for signs of flooding, don't open if floodsling is suspected |
|
What does DECK mean when escaping a toxic environment? |
- don EEBD, place on casualties, put in recovery position - evacuate - check/confirm last out, close compartment - keep high |
|
What does the multi gas detector monitor and how are they measured? |
- oxygen % - LEL combustible gases % - H2S ppm - CO ppm |
|
Class A |
Combustt solids |
|
Class B |
Combustible liquids |
|
Class C |
Combustible gasses |
|
Class D (dentable) |
Combustible metals |
|
Class E |
Electrical fires |
|
Class F |
Fats and oil fire |
|
Full fire fighting rig |
- action working dress - antiflash worn - breathing apparatus - Bristol suit - helmet - mine spot - FF gloves |
|
If you discover a fire, what are your initial actions? |
Raise the alarm Take appropriate first aid response (fight the fire) |
|
If the fire gains on you? |
Control the door/shut down the compartment Get help but return with the right/more equipment, lay out hoses |
|
Three tasks of reflash watch |
- break up any combustible material and remove from scene - wet any embers - watch and monitor the scene preventing fire from reflashing |
|
A in AFHC |
Air; reset Demand Valve and ensure bypass valve is closed. Turn on cylinder, check pressure is 280-300 bar, check for leaks. Turn off cylinder, activate bypass valve and listen for whistle at 44 bar. Turn off bypass valve |
|
F in AFHC |
Fittings; Demand Valve is secure to face mask
|
|
H in AFHC |
Harness; check all straps are fully extended, including face mask, no fraying, damage or wear |
|
C in AFHC |
Checks; tally matches set, activate and reset life call |
|
Four duties of containment party |
- establish the immediate boundary and rig cooling hoses - supply TIC to SL - TMS - remove flammable material from the area |
|
Immediate self-aid drill steps and doses |
- 1 combo pen followed by winged diazepam - seek medical advice - if symptoms persist after 15 mins take another combo pen - of symptoms persist after a following 15 min, take atropine |
|
Frigate is cruising, who do you ask for permission to open an X door? |
OOW |
|
Where must you turn on a gas monitor? |
Clean air environment |
|
What 4 occasions are SSD required for? |
- fog/gale - narrow waters - ras - entering/leaving harbour |
|
What is the main purpose of shoring? |
To support leak stopping devices and weakened structures |
|
What does a DCBA contain? |
Compressed breathable air |
|
How long will an AFFF extinguisher last for? |
45 sec |
|
What is the contact message procedure on CBRNDC open line? |
What Where Action taken Time |
|
4 portable pumps in the RNZN |
- Britton - yanmar - weda - portable eductor |
|
What are the ships companies actions upon hearing "hands to emergency stations"? |
- on watch personnel stay on watch - those taking first aid action continue to do so until relieved - CBRNDC close up as per state 1 - spare hands do as directed by command - either stay in place or muster at muster stations |
|
Four golden rules of fire fighting |
- water wall opposite the hinges - always cool the compartment - waterwall first one in - waterwall last one out |
|
Five fixed fire fighting installations? |
- wet chemical (K5) - fixed foam FF system - water mist - chemical mist - Potassium carbonate |
|
Three types of FF hose sizes and where they are normally used |
- size 1; 38mm, FF between decks - size 2; 50mm FF on upper decks with FB5X and Yanmar - size 3; 70mm, FF on flight deck, pumping discharge and breeching |
|
Task of reflash watch |
- extinguish fire if reflashes - relieve FF team - commence overhauling |
|
Steps for immediate action drill |
- hold breath, close eyes, lean forward - don respirator in 9 sec or less - breathe out, yell GAS! GAS! GAS! - carry out suction test - decontaminate hands and exposed skin, conduct face seal check - ensure all equipment and gear is on correctly, check oppos too - conduct chemical testing, report findings |
|
What does NAPs tablets stand for and how often are they taken? |
Nerve Agent Pre treatment set
Every 8 hours as directed by command |
|
Chemical agents detectors used |
- one colour detector paper - CAM - sics - 3 colour detector paper - water testing kit |
|
CO2 extinguisher colour, duration, and fire |
Black band 20 sec Best for electrical but ABCF |
|
AFFF extinguisher colour, duration, and fires |
Blue band 45 sec ABF avoid electrical |
|
Dry powder extinguisher, colour, duration, and fires |
White band 20 sec ABCF, not ideal for electrical |
|
Hose size 1 details |
38mm Stowed between decks |
|
Hose size 2 details |
50mm Stowed in upper decks and between decks with FB5X Yanmar pump discharge |
|
Hose size 3 details |
70mm Stowed in flight and used in upper decks Used for discharge and breeching |
|
What type of hoze nozzle is used on the flight deck? |
FB10-10 |
|
What are containment party duties |
- establish immediate boundary - give TIC to SL - remove all flammable materials that are near fire boundary - limits smoke and establish smoke boundaries - rig boundary cooling and monitoring with TMS - cover electrical equipment |
|
What is the temperature monitoring systems (TMS) |
- rototherms (magnetic dials on doors) - infrared thermo gun - temp points - HQ1 record sheets |
|
Name 5 scenarios which would cause the ship to come to emergency stations |
- fire - collision/grounding - aircraft/explosive accident - flooding - 2+ casualties |
|
What is a hot or cold entry? |
Hot entry is heat detected Cold entry is no heat detected |
|
What is the chemical safety? Distress |
- dimness of vision - irritation of the eyes - sudden headache - tightness of the chest - running nose - excessive salivation - see suspicious aircraft, mist, smoke - smell unusual odours |
|
What rule should be applied when cutting shoring timber? |
Vertical -40mm Horizontal/square +20mm Proud shore +20mm To accomodate for pad pieces |
|
What is a normal entry for FF team? |
|
|
What are the FF teams position for a confined space entry? |
|
|
What is the position of FF team for a hatch entry? |
|
|
What does a FF team consist of and the individual equipment? |
TP - full FF rig; no 1 hose with MRN FF - full FF rig; no 1 hose with MRN TL - full FF rig; magnet, lanyard, TIC HT - full FF rig Bacon - basic FF rig, BA board, chinograph, magnet, watch, EEBD |
|
What does full FF rig consist of? |
- Action working dress - antiflash hood - mine spot - helmet - Bristol suit - BA - FF gloves - boots |
|
Name 3 leak stopping devices |
- splinter box - GRP dome - wedges |
|
Name 4 shoring equipment pieces
|
- 10lb maul - 2lb engineers hammer - Gunter batten - cross cut saw - Emms clamps |