• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/76

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

76 Cards in this Set

  • Front
  • Back

Which zone of damage will there be complete destruction?

Primary zone

What are the zones of destruction?

- Primary


- Secondary


- Remote

A waste paper basket is burning, what class of fire is it?

Alpha

In which situation would Hands To Emergency Stations be piped?


- Large machinery space fire


- Multiple replenishment at sea


- Entering or leaving a narrow channel


- Incoming enemy aircraft

Large machinery space fire

On a frigate in state Z, condition 1. You want an X opening. Where do you get permission from?

HQ1

What is the primary CBRNDC communication circuit called?

CBRNDC Open line

What drill would be carried out upon hearing the chemical alarm?

Immediate action drill

Heat can be transferred through metal bulkheads by?

Conduction

In peace time/harbour time who is responsible for watertight integrity?

OOD

Where would you find emergency stations duty laid down?

Ships watch and station bill

What is the main purpose of leak stopping?

Reduce flow of water to the rate pumps can handle

What does H2S stand for?

Hydrogen sulphide

What is the duration of an EEBD?

10 min

How long does a dry powder extinguisher last for?

20 sec

Which pump is not intrinsically safe?

Yanmar

What is the primary use of a Britton Marine FSP 36?

Emergency fire pump

What colour will the one colour detector paper turn when contaminated?

Navy blue spotting

State 2 shoring tools used in the RNZN

- Gunter batten


- 10lb maul


- 2lb hammer


- Crosscut saw


Name 3 recognised leak stopping devices

- splinter box


- pipe clamps


- wedges


- GRP dome

What actions are to be taken upon hearing "close all red openings"

- close all red openings in your vicinity


- remain until further action piped by command

Seven rules of shoring

- always cut remote scene


- always set a shoring watch


- always use a Gunter batten


- always shore against structure


- never pre erect


- never pre cut


- never use shoring timber less than 30 times it's minimum width

The ship is in state 1, condition Z, hands are at action stations. The ship has been hit by enemy fire. A blanket search has been initiated. Two things must be done prior to opening hatch/door. What are they and what do you do?

Fire; check with the back of your hand, don't open if fire is suspected.



Flood; crack the hatch slowly, look listen for signs of flooding, don't open if floodsling is suspected

What does DECK mean when escaping a toxic environment?

- don EEBD, place on casualties, put in recovery position


- evacuate


- check/confirm last out, close compartment


- keep high

What does the multi gas detector monitor and how are they measured?

- oxygen %


- LEL combustible gases %


- H2S ppm


- CO ppm

Class A

Combustt solids

Class B

Combustible liquids

Class C

Combustible gasses

Class D (dentable)

Combustible metals

Class E

Electrical fires

Class F

Fats and oil fire

Full fire fighting rig

- action working dress


- antiflash worn


- breathing apparatus


- Bristol suit


- helmet


- mine spot


- FF gloves

If you discover a fire, what are your initial actions?

Raise the alarm



Take appropriate first aid response (fight the fire)

If the fire gains on you?

Control the door/shut down the compartment



Get help but return with the right/more equipment, lay out hoses

Three tasks of reflash watch

- break up any combustible material and remove from scene


- wet any embers


- watch and monitor the scene preventing fire from reflashing

A in AFHC

Air; reset Demand Valve and ensure bypass valve is closed. Turn on cylinder, check pressure is 280-300 bar, check for leaks. Turn off cylinder, activate bypass valve and listen for whistle at 44 bar. Turn off bypass valve

F in AFHC

Fittings; Demand Valve is secure to face mask


H in AFHC

Harness; check all straps are fully extended, including face mask, no fraying, damage or wear

C in AFHC

Checks; tally matches set, activate and reset life call

Four duties of containment party

- establish the immediate boundary and rig cooling hoses


- supply TIC to SL


- TMS


- remove flammable material from the area

Immediate self-aid drill steps and doses

- 1 combo pen followed by winged diazepam


- seek medical advice


- if symptoms persist after 15 mins take another combo pen


- of symptoms persist after a following 15 min, take atropine

Frigate is cruising, who do you ask for permission to open an X door?

OOW

Where must you turn on a gas monitor?

Clean air environment

What 4 occasions are SSD required for?

- fog/gale


- narrow waters


- ras


- entering/leaving harbour

What is the main purpose of shoring?

To support leak stopping devices and weakened structures

What does a DCBA contain?

Compressed breathable air

How long will an AFFF extinguisher last for?

45 sec

What is the contact message procedure on CBRNDC open line?

What


Where


Action taken


Time

4 portable pumps in the RNZN

- Britton


- yanmar


- weda


- portable eductor

What are the ships companies actions upon hearing "hands to emergency stations"?

- on watch personnel stay on watch


- those taking first aid action continue to do so until relieved


- CBRNDC close up as per state 1


- spare hands do as directed by command - either stay in place or muster at muster stations

Four golden rules of fire fighting

- water wall opposite the hinges


- always cool the compartment


- waterwall first one in


- waterwall last one out

Five fixed fire fighting installations?

- wet chemical (K5)


- fixed foam FF system


- water mist


- chemical mist


- Potassium carbonate

Three types of FF hose sizes and where they are normally used

- size 1; 38mm, FF between decks


- size 2; 50mm FF on upper decks with FB5X and Yanmar


- size 3; 70mm, FF on flight deck, pumping discharge and breeching

Task of reflash watch

- extinguish fire if reflashes


- relieve FF team


- commence overhauling


Steps for immediate action drill

- hold breath, close eyes, lean forward


- don respirator in 9 sec or less


- breathe out, yell GAS! GAS! GAS!


- carry out suction test


- decontaminate hands and exposed skin, conduct face seal check


- ensure all equipment and gear is on correctly, check oppos too


- conduct chemical testing, report findings

What does NAPs tablets stand for and how often are they taken?

Nerve Agent Pre treatment set



Every 8 hours as directed by command

Chemical agents detectors used

- one colour detector paper


- CAM


- sics


- 3 colour detector paper


- water testing kit

CO2 extinguisher colour, duration, and fire

Black band


20 sec


Best for electrical but ABCF

AFFF extinguisher colour, duration, and fires

Blue band


45 sec


ABF avoid electrical

Dry powder extinguisher, colour, duration, and fires

White band


20 sec


ABCF, not ideal for electrical

Hose size 1 details

38mm


Stowed between decks

Hose size 2 details

50mm


Stowed in upper decks and between decks with FB5X


Yanmar pump discharge

Hose size 3 details

70mm


Stowed in flight and used in upper decks


Used for discharge and breeching

What type of hoze nozzle is used on the flight deck?

FB10-10

What are containment party duties

- establish immediate boundary


- give TIC to SL


- remove all flammable materials that are near fire boundary


- limits smoke and establish smoke boundaries


- rig boundary cooling and monitoring with TMS


- cover electrical equipment

What is the temperature monitoring systems (TMS)

- rototherms (magnetic dials on doors)


- infrared thermo gun


- temp points


- HQ1 record sheets

Name 5 scenarios which would cause the ship to come to emergency stations

- fire


- collision/grounding


- aircraft/explosive accident


- flooding


- 2+ casualties

What is a hot or cold entry?

Hot entry is heat detected



Cold entry is no heat detected

What is the chemical safety? Distress

- dimness of vision


- irritation of the eyes


- sudden headache


- tightness of the chest


- running nose


- excessive salivation


- see suspicious aircraft, mist, smoke


- smell unusual odours

What rule should be applied when cutting shoring timber?

Vertical -40mm


Horizontal/square +20mm


Proud shore +20mm


To accomodate for pad pieces

What is a normal entry for FF team?

What are the FF teams position for a confined space entry?

What is the position of FF team for a hatch entry?

What does a FF team consist of and the individual equipment?

TP - full FF rig; no 1 hose with MRN


FF - full FF rig; no 1 hose with MRN


TL - full FF rig; magnet, lanyard, TIC


HT - full FF rig


Bacon - basic FF rig, BA board, chinograph, magnet, watch, EEBD

What does full FF rig consist of?

- Action working dress


- antiflash hood


- mine spot


- helmet


- Bristol suit


- BA


- FF gloves


- boots

Name 3 leak stopping devices

- splinter box


- GRP dome


- wedges

Name 4 shoring equipment pieces


- 10lb maul


- 2lb engineers hammer


- Gunter batten


- cross cut saw


- Emms clamps