What is the function of the Closed Cooling Water System?
|
Remove heat generated in components located in the Turbine Building and transfer the heat to the Service Water System.
|
|
What chemicals are added to the Closed Cooling Water System?
|
Sodium Molybdates to maintain a passive film on piping. Sodium Tolytriazole is used as a copper corrosion inhibitor.
|
|
The function of the Closed Cooling Water surge tank is to:
|
Provides expansion and contraction of the cooling water and provides for leakage from the system and makeup.
|
|
Where is the Closed Cooling Water System pump and heat exchangers physically located?
|
Turbine building 2000' elev., north end.
|
|
Question: Which components of the Main Generator System does the Closed Cooling Water System cool?
|
Answer: Generator exciter and isophase bus duct cooler.
|
|
Temperature control valve, EB TV-9, loses its instrument air supply. What happens to the valve and system flow?
|
EB TV-9 fails closed sending full system flow through the heat exchangers.
|
|
Can leakage from the Closed Cooling Water System be discharged directly to the environment without contacting the Chemistry Department?
|