  • Front
  • Back

The open-circuit voltage between the two terminals of a single pole switch on a lighting circuit when the switch is in the off position is

120 volts

An arc flash can produce temperatures of _______ degrees Fahrenheit.

35,000

Listing and labeling of electrical equipment is done by a ______?

Recognized testing Laboratory

The purpose of electrical symbols on plans is ______?

To provide a code to prevent untrained persons from doing electrical


The national electrical code is a minimum ______ standard

Safety

The meaning of approved is ______?

Acceptable to the authority having jurisdiction

All measurements in the National electrical code are shown in which systems of unit

Both inch-pounds and metric value

In the industrial System of Units the prefix kilo means ______?

Thousand

Nationally recognized Testing Laboratories ______ electrical products to provide the basis of approval by inspectors in the field

Test and list

Devices are equipment who's primary function is to carry current not

Utilize electric energy

All the following items of electrical equipment are devices except for a _____.



Receptacle



Three-way switch



Lamp



Disconnect switch

Lamp

The NEC requires that a _____ be installed at each conductor splice connection point

Box or conduit body

In the International System of Units the prefix milli means _____?

One thousandth

In order that connections inside an outlet box remain accessible NEC requires that a surface extensions from an outlet box cover be made using ____

Flexible conduit

Electrical wall boxes should not be mounted back-to-back in walls because

Sounds may be transferred from room to room



It reduces the fire resistance of the wall



The practice violate building codes

According to ______ unused Knockouts and other openings in electrical boxes and cabinets are required to be closed

Article 100



NEC 110 .12 a

Device faceplates must be mounted so as to

Cover the opening in the wall



Feet against the wall surface

A receptacle Outlet is _____

A contact device for the connection attachment plug

Where non-combustible surface material is used on walls or ceiling outlet boxes must be mounted so that they will be back not more than ______ from the face of the surface material

1/4 inch

As defined in article 100 a dwelling unit has the following features

Permanent Provisions for living sleeping cooking and sanitation

A 20 ampere Appliance circuits required by NEC are permitted to serve no other load except for

One outdoor GFCI protected receptacle

NEC article 210 provides --- guidelines for locating receptacles outlets in Residence

Mandatory

Wall receptacles in a habitable room must be placed so they are no further than --- from any point along the wall

6 feet

A continuous load shall not exceed --- of the rating of the branch circuit

80%

Where fixed glass panes do not permit installation of wall mounted receptacle --- are typically used to satisfy the receptacle spacing required of the NEC

Floor mounted receptacles

In construction of one and two family dwellings the electrical circuits are usually designed by the

Electrician

The minimum lighting load requirement for dwelling units is --- per square foot

3 volt amperes

How is track lighting load in Residence calculated?

It is considered to be part of the general lighting load of 3 volt amperes per square foot

A 20 ampere branch circuit requires --- AWG conductors ignoring the effects of voltage drop

12 copper

Small appliance receptacle Outlets --- included in the three volt ampere per square foot load calculation

Are not

12 foot rule for spacing receptacles applies to all of the following areas of the house except for

The Attic

The National Electric Code requires receptacles installed in a garage to be

GFCI protected

All of the following are included when calculating an unused area of a dwelling to compute the required lighting load except for

Crawl space

Name several factors that may be taken into account when sizing boxes per the NEC

Wire size ,



Amount of wiring in a box ,



Number of outlets being installed

Explain what is meant by a normal cage rating

A piece of equipment that will use plus or minus 10%

What is the purpose of the National Electric Code?

The safeguarding of persons and property from electrical hazards

How is an outlet defined by the NEC?

A point on the wiring system at which current is taken to supply utilisation equipment

Explain the requirements for installing lighting fixture more than 50 pounds

The Box must be rated for the weight of the lighting

Explain the difference between a receptacle and a receptacle Outlet

A receptacle is a contact device installed at the outlet for connection attachment plug



A receptacle Outlet is an outlet one or more receptacles are installed

Explain why the code in general discourages mounting receptacle below the edge of kitchen countertops

Children are able to reach them

Calculate the minimum number of 15 ampere lighting Branch circuits required 1850 square feet

3 amperes X 1850 feet



/ 120 volt



Equals 46.25 amps



46.25 divided by 15



Equals 3.083



4 ampere lighting branch circuits are required

What is the NEC definition for a qualified person

A person who is skilled and knowledgeable relating to the construction and operation of electrical equipment and installation, and has safety training to recognize hazards.

What is meant by fire resistance rating?

The amount of time a wall can resist a fire

Name the kitchen receptacles that are not required to be protected by ground fault circuit interrupters

All designated Outlets such as microwave , gas range, refrigerator

In walls or ceilings constructed of non combustible materials such as concrete or tile The Edge outlet boxes permitted to be set back not more than --- from the finished surface

1/4 inch

Nationally recognized Testing Laboratories test and evaluate products for

Safety

Receptacles are not permitted to be mounted directly over --- heaters in residential construction

Baseboard

The Authority having jurisdiction over electrical construction is generally the

Local inspector

Device boxes are designed for what size screws

6 - 32 in and 10 - 32 inch

Where there are --- or more on the interior stairway a wall switch control stairway lighting must be provided on each floor level and level has an entryway

6 risers

--- provide additional information about a job that may not be found on the blueprints

Specifications

Lighting outlet boxes are designed for what size screws?

8 - 32 inch and 10 - 32 inch