Btu formula |
Gallons x Delta T (degree chance) x 8.33 lbs |
|
B vent |
Steel insulated vent pipe |
|
Causes for backdraft |
Not sized correctly Location of vent Tree growth Addition to house |
|
Vent termination |
3 ft above roof, 2 feet above wall or roof within 10 ft of vent termination |
|
Smoke pipe pitch |
1/4" per foot |
|
Make up air |
1000 btus ÷ 50 cubic ft of air = 1 cubic ft of air = Supports 20 btus |
|
Inside make up air 1 square in = ___ btus |
1,000 btus |
|
Outside horizontal ducts 1 square inch = ___ btus |
2,000 btus |
|
Directly from outside 1 square inch = ____ btus |
4,000 btus |
|
The opening directly from outside 1 square in = ___ btus |
3,000 btus |
|
Atmospheric pressure at sea level |
14.7 psi |
|
High altitude above 2,000 feet |
4% reduction of input rating of equipment |
|
Capacity of gallons of pipes and tanks |
Diameter in square x L in x .0034 Diameter in square x L ft x .0408 Diameter ft square x L ft x 5.87 |
|
Horizontal vents |
Single wall- 75% of chimney height Double wall- 100% of chimney height |
|
Specific gravity of Natural gas |
.60 |
|
Specific gravity of LP (propane) |
1.5 |
|
Underground gas pipe |
Direct burial Coated steel pipe with tape Csst Soft Copper on LP if sulfites too high no copper on natural gas |
|
Heating value of Natural gas |
1000 |
|
Heating value of LP |
2500 |