STANDPIPE

A NETWORK OF PIPING AND COMPONENTS THAT TRANSPORTS WATER TO PROVIDE READY ACCESS TO A WATER DELIVERY SYSTEM FOR MANUAL FIREFIGHTING IS KNOWN AS

SIAMESE CONNECTION

A PIPE FITTING INSTALLED CLOSE TO THE GROUND ON THE EXTERIOR OF A BUILDING, PROVIDING TWO OR MORE CONNECTIONS THROUGH WHICH THE FIRE DEPARTMENT CAN PUMP WATER TO A STANDPIPE OR SPRINKLER SYSTEM.

WET STANDPIPE

A STANDPIPE CONTAINING WATER UNDER PRESSURE AND FITTED WITH FIRE HOSES OR EMERGENCY USE BY BUILDING OCCUPANCE

DRY STANDPIPE

A STANDPIPE CONTAINING NO WATER AND USED BY THE FIRE DEPARTMENT TO CONNECT FIRE HOSES TO A FIRE HYDRANT OR TO A PUMPER TRUCK.

FIRE EXTINGUISHER

A PORTABLE APPARATUS FOR PUTTING A SMALL FIRE BY EJECTING PRESSURIZED WATER OR SPECIAL CHEMICALS, CLASSIFIED ACCORDING TO THE TYPE OF FIRE IT IS ABLE TO EXTINGUISH

SPRINKLER HEADS

THESE ARE OF THE QUANZOID BULB TYPE. THE BULB IS TRANSPARENT AND CONTAINS A COLORED LIQUID. AT 136°F THE BULB BREAKS AND RELEASES A WATER STREAM.

UPRIGHT SPRINKLER

THIS TYPE IS USED ABOVE PIPING WHEN PIPING IS EXPOSED. IT IS SAFER AGAINST DAMAGE BY WORKERS.

PENDENT SPRINKLER

THIS TYPE PROJECTS THROUGH A FINISHED CEILING WHEN PIPING IS CONCEALED.

SPRINKLER HEAD

A NOZZLE IN A SPRINKLER SYSTEM FOR DISPERSING A STREAM OR SPRAY OF WATER, USUALLY CONTROLLED BY A FUSIBLE LINK THAT MELTS AT A PREDETERMINED TEMPERATURE.

SPRINKLER SYSTEM

APPARATUS FOR AUTOMATICALLY EXTINGUISHING FIRES OF THE BUILDING, CONSISTING OF A SYSTEM OF PIPES IN OR BELOW THE CEILINGS, CONNECTED TO A SUITABLE WATER SUPPLY, AND SUPPLIED WITH VALVES OR SPRINKLER HEADS MADE TO OPEN AUTOMATICALLY AT A CERTAIN TEMPERATURE.

EMERGENCY LIGHTING

A LIGHTING SYSTEM DESIGNED TO SUPPLY THE ILLUMINATION REQUIRED FOR SAFE EGRESS FROM A BUILDING IN THE EVENT OF A POWER FAILURE

915 mm

EXISTING STAIRS MINIMUM CLEAR WIDTH ( mm )

205 mm

MAXIMUM HEIGHT OF RISERS FOR EXISTING STAIRS

230 mm

MINIMUM TREAD DEPTH FOR EXISTING STAIRS

280 mm

SPIRAL STAIRS MINIMUM TREAD DEPTH ( FCP ).

760 mm - 865 mm

MINIMUM TO MAXIMUM HEIGHT OF HANDRAILS ON STAIRS ABOVE THE UPPER SURFACE OF THE TREAD ( FCP )

38 mm

MINIMUM CLEARANCE BETWEEN HANDRAIL AND WALL TO WHICH IT IS FASTENED ( FCP )

910 mm

MINIMUM HEIGHT OF GUARDS PROTECTING CHANGES IN LEVEL ONE STOREY OR LESS ON INTERIOR BALCONIES AND MEZZANINES

7.5 M

RADIUS OF MONUMENTAL STAIRS AT THE INNER EDGES

1120 mm

MINIMUM WIDTH OF RAMPS UNDER FCP ( mm )

150 mm , 280 mm

UNDER FCP, WINDERS SHALL BE PERMITTED IN STAIRS, PROVIDED THAT THE MINIMUM TREAD DEPTH AT THE NARROWEST IS ( BLANK ) AND THE MINIMUM TREAD DEPTH SHALL BE ( BLANK ) AT A POINT 305 mm FROM THE NARROWEST EDGE

1 : 12

MAXIMUM SLOPE OF RAMPS ( FCP )

1 : 48

MAXIMUM CROSS SLOPE OF RAMPS ( FCP )

760 mm

MAXIMUM RISE FOR A SINGLE RAMP RUN IN mm ( FCP )

1220 mm

MINIMUM HEIGHT FOR OUTSIDE RAMPS MORE THAN 3 STOREYS

FIRE ESCAPE STAIRS

MAY BE USED IN REQUIRED MEANS OF EGRESS ONLY IN EXISTING BUILDINGS; SHALL NOT CONSTITUTE MORE THAN 50 % OF THE REQUIRED EXIT CAPACITY IN ANY CASE

600 mm

MINIMUM WIDTH OF FIRE ESCAPE STAIRS ( mm )

600 mm

MINIMUM HORIZONTAL DIMENSION ANY LANDING OF PLATFORM FOR FIRE ESCAPE STAIRS ( mm )

230 mm

MAXIMUM RISE OF FIRE ESCAPE STAIRS

230 mm

MINIMUM TREAD, EXCLUSIVE OF NOSING OF FIRE ESCAPE STAIRS

610 mm BY 1980 mm

ACCESS TO ESCAPE DIMENSION FOR FIRE ESCAPE STAIRS, SUCH AS DOOR OR CASEMENT WINDOW ( mm )

1070 mm

HEIGHT OF GUARDS ON BOTH SIDES FOR FIRE ESCAPE STAIRS

760 mm - 1070 mm

MINIMUM TO MAXIMUM HANDRAIL HEIGHT FOR FIRE ESCAPE STAIRS

LADDERS

SHALL NOT BE ALLOWED AS A FIRE ESCAPE OR MEANS OF EGRESS, MAY BE USED TO PROVIDE ACCESS TO UNOCCUPIED ROOF SPACES

3 M

MAXIMUM INTERVALS OF ALL LADDERS PERMANENTLY INSTALLED IN FIXED POSITION, SUPPORTED BY RIGID CONNECTION TO THE BUILDING OR STUCTURE.

10.7 LUX

MINIMUM VALUE OF ILLUMINATION OF MEANS OF EGRESS ILLUMINATED AT ALL POINTS INCLUDING ANGLES AND INTERSECTIONS OF CORRIDORS AND PASSAGEWAYS, LANDINGS OF STAIRS, AND EXIT DOORS.

1.5 HOURS

MINIMUM PERIOD OF EMERGENCY LIGHTING FACILITIES SHALL MAINTAIN THE SPECIFIED DEGREE OF ILLUMINATION IN THE EVENT OF FAILURE OF THE NORMAL LIGHTING

15 CM BY 19 MM

EVERY EXIT SHALL HAVE THE WORD "EXIT" IN PLAINLY LEGIBLY LETTERS NOT LESS THAN ( BLANK ) HIGH WITH THE PRINCIPAL STROKES OF LETTERS NOT LESS THAN ( BLANK ) WIDE.

EMERGENCY FORCES NOTIFICATION

WHEN REQUIRED, A NOTIFICATION SHALL BE PROVIDED TO ALERT THE NEAREST FIRE STATION AND FIRE BRIGADE IN CASE OF FIRE OR OTHER EMERGENCY.

AUTOMATIC FIRE DEPARTMENT NOTIFICATION

A NOTIFICATION SHALL BE MANDATORY TO THE FOLLOWING TYPES OF OCCUPANCY:


- HIGH RISE BUILDINGS


- HOSPITALS


- EDUCATIONAL INSTITUTIONS, HOTELS AND APARTMENTS 4 STOREYS OR TALLER


- MALLS

1860 SQM

WHEN ALARM ANNUNCIATION IS REQUIRED, IF A FLOOR AREA EXCEEDS AN AREA ( BLANK ), ADDITIONAL ZONING SHALL BE PROVIDED, AND A LENGTH OF ANY SINGLE ZONE SHALL NOT EXCEED 910 mm IN ANY DIRECTION

CLASS I SYSTEM

CLASS OF STANDPIPE SYSTEM PROVIDED WITH 64 mm ( 2 1/2 IN ) HOSE CONNECTIONS FOR FULL - SCALE FIREFIGHTING; USUALLY LOCATED ON EXITS

CLASS II SYSTEM

CLASS OF STANDPIPE SYSTEM PROVIDED WITH 38 mm ( 1 1/2 IN ) HOSE OR WITHIN 37 M. OF A HOSE CONNECTION SYSTEM, ALL PORTIONS OF EACH FLOOR LEVEL OF THE BUILDING ARE WITHIN 40 M.

CLASS III SYSTEM

CLASS OF STANDPIPE SYSTEM PROVIDED WITH HOSE CONNECTIONS AS REQUIRED FOR BOTH CLASS I AND CLASS II SYSTEM

DRY STANDPIPE

AN OUTLET CONNECTION SHALL BE PROVIDED AT EVERY FLOOR LEVEL LANDING ABOVE THE FIRST FLOOR OF EVERY REQUIRED ENCLOSED STAIRWAY OR SMOKEPROOF ENCLOSURE; SHALL NOT BE CONCEALED IN BUILDING WALL OR BUILT INTO PILASTERS

WET STANDPIPE

A STANDPIPE SYSTEM IS NOT REQUIRED TO BUILDINGS, BASEMENT OR CELLARS EQUIPPED WITH AN APPROVED, SUPERVISED SPRINKLER SYSTEM.

1000

A WET STANDPIPE IS REQUIRED FOR ASSEMBLY OCCUPANCIES WITH AT LEAST HOW MANY OCCUPANT LOAD

4 STOREYS

A WET STANDPIPE IS REQUIRED FOR SCHOOLS, HOSPITALS, BUSINESSES, HOTELS, ETC. WITH AT LEAST HOW MANY STOREYS

1860 SQM

A WET STANDPIPE IS REQUIRED FOR HAZARDOUS OCCUPANCIES EXCEEDING HOW MANY SQM PER FLOOR

6 M, 22 M

WET STANDPIPES SHALL BE LOCATED SO THAT ALL PORTIONS OF THE BUILDINGS ARE WITHIN ( BLANK ) METERS OF A NOZZLE ATTACHED TO ( BLANK ) METERS OF HOSE.

64 mm

MINIMUM DIAMETER OF WET STANDPIPES

150 mm

MINIMUM DIAMETER OF COMBINATION STANDPIPES

0.65 SQM

OCCUPANT LOAD IN PLACES OF ASSEMBLY OF CONCENTRATED USE WITHOUT FIXED SEATS, SUCH AS PLACES OF WORSHIP, DANCE FLOORS

1.4 SQM

OCCUPANT LOAD IN PLACES OF ASSEMBLY OF LESS CONCENTRATED USE SUCH AS CONFERENCE ROOMS, DINING ROOM, DRINKING ESTABLISHMENT, EXHIBIT ROOM, GYMNASIUM, OR LOUNGE

0.28 SQM

OCCUPANT LOAD FOR STANDING ROOM OR WAITING SPACE IN PLACES OF ASSEMBLY

1120 mm

MINIMUM WIDTH OF ANY EXIT ACCESS CORRIDOR SERVING 50 OR MORE PERSONS ( FCP )

61 M

TRAVEL DISTANCE FROM ANY POINT TO REACH AN EXIT IN ANY PLACE OF ASSEMBLY WITH SPRINKLER SYSTEM ( FCP )

6.1 M

MAXIMUM LENGTH OF DEAD - END AISLE.

680 mm

MINIMUM SPACING PLUS THE SUM OF THE THICKNESS OF THE BACK AND INCLINATION OF THE BACK OF SEATS ( mm )

RA 9514

IT IS THE POLICY OF THE STATE TO ENSURE PUBLIC SAFETY, PROMOTE ECONOMIC DEVELOPMENT THROUGH THE PREVENTION AND SUPPRESSION OF ALL KINDS, OF DESTRUCTIVE FIRES, AND PROMOTE THE PROFESSIONALIZATION OF THE FIRE.

ABATEMENT

ANY ACT THAT WOULD REMOVE OR NEUTRALIZE A FIRE HAZARD

AUTOMATIC FIRE SUPPRESSION SYSTEM

AN INTEGRADETED UNDERGROUND OR OVERHEAD PIPING SYSTEM CONNECTED TO A SOURCE OF EXTINGUISHING AGENT WHICH SUPPRESSES FIRES WHEN ACTUATED BY ITS AUTOMATIC DETECTING DEVICE

BLASTING AGENT

ANY MATERIAL OR MIXTURE CONSISTING OF A FUEL AND OXIDIZER USED TO SET OFF EXPLOSIVES

BLOWOUT

A SUDDEN RELEASE OF OIL AND GAS FROM A WELL

CARGO TANK

ANY TANK HAVING A LIQUID CAPACITY MORE THAN 450 L USED FOR CARRYING FLAMMABLE AND COMBUSTIBLE LIQUIDS AND MOUNTED PERMANENTLY OR UPON A TANK VEHICLE

FIRE MARSHAL

THE DULY DESIGNATED HEAD OF THE CITY OR MUNICIPAL FIRE STATION

CLASS A

FIRES INVOLVING ORDINARY COMBUSTIBLE MATERIALS SUCH AS WOOD, CLOTH, RUBBER AND PLASTICS.

CLASS B

FIRES INVOLVING FLAMMABLE LIQUIDS AND GASES

CLASS C

FIRES INVOLVING ENERGIZED ELECTRICAL EQUIPMENT

CLASS D

FIRES INVOLVING COMBUSTIBLE MATERIALS, SUCH AS SODIUM, MAGNESIUM, POTASSIUM, AND OTHER SIMILAR MATERIALS.

CLASS K

FIRES IN COOKING APPLIANCES THAT INVOLVE COMBUSTIBLE COOKING MEDIA ( VEGETABLE OR ANIMAL OILS AND FATS )

DRY STANDPIPE

A TYPE OF STANDPIPE SYSTEM IN WHICH THE PIPES ARE NORMALLY NOT FILLED WITH WATER ; WATER IS INTRODUCED INTO THE SYSTEM THRU FIRE SERVICE CONNECTIONS WHEN NEEDED

FIRE ALARM

ANY VISUAL OR AUDIBLE SIGNAL PRODUCED BY A DEVICE OR SYSTEM TO WARN THE OCCUPANTS OF THE BUILDING OR FIRE FIGHTING ELEMENTS OF THE PRESENCE OR DANGER OF FIRE.

FIRE ALERTING SYSTEM

A FIRE ALARM SYSTEM ACTIVATED BY THE PRESENCE OF FIRE , WHERE THE SIGNAL IS TRANSMITTED TO DESIGNATED LOCATIONS INSTEAD OF SOUNDING A GENERAL ALARM

FIRE DOOR

A FIRE RESISTIVE DOOR PRESCRIBED FOR OPENINGS IN FIRE SEPARATION WALLS OR PARTITIONS

FIRE EXIT DRILL

A PRACTICE DRILL FOR THE ORDERLY AND SAFE EVACUATION OF OCCUPANTS IN THE BUILDINGS

FIRE HAZARD

ANY CONDITION OR ACT WHICH INCREASES OR MAY CAUSE AN INCREASE IN THE PROBABILITY OF THE OCCURRENCE OF FIRE, OR WHICH MAY OBSTRUCT, DELAY, HINDER OR INTERFERE WITH FIRE FIGHTING OPERATIONS.

FIRE LANE

THE PORTION OF A ROADWAY OR PUBLIC WAY THAT SHOULD BE KEPT OPENED AND UNOBSTRUCTED AT ALL TIMES FOR THE EXPEDIENT CONDUCT OF FIRE FIGHTING OPERATIONS

FIRE PROTECTIVE AND FIRE SAFETY DEVICE

ANY DEVICE INTENDED FOR THE PROTECTION OF BUILDINGS OR PERSONS TO INCLUDE, BUILT - IN PROTECTION SYSTEM, DETECTORS FOR HEAT, SMOKE AND COMBUSTION PRODUCTS, AND PERSONAL PROTECTIVE EQUIPMENT

FIRE PROTECTIVE ASSEMBLY

AN ASSEMBLY INCORPORATED IN THE STRUCTURE DESIGNED TO PREVENT THE SPREAD OF FIRE, SUCH AS DAMPERS, CURTAIN BOARDS, FIRE STOPPERS AND THE LIKE

FIRE RESISTANCE RATING

THE TIME DURATION THAT A MATERIAL OR CONSTRUCTION CAN WITHSTAND THE EFFECT OF A STANDARD FIRE TEST

FIRE DEPARTMENT HOSE CONNECTION

A HOSE CONNECTION AT GRADE OR STREET LEVEL FOR USE BY THE FIRE SERVICE ONLY ; ALSO KNOWN AS FIRE SERVICE CONNECTION

FIRE TRAP

A BUILDING UNSAFE IN CASE OF FIRE


BECAUSE IT WILL BURN EASILY OR IT LACKS ADEQUATE EXITS OR FIRE ESCAPES.

FIREWALL

A WALL DESIGNED TO PREVENT THE SPREAD OF FIRE, HAVING A FIRE RESISTANCE RATING OF NOT LESS THAN 4 HOURS WITH SUFFICIENT STRUCTURAL STABILITY TO REMAIN STANDING EVEN IF CONSTRUCTION ON EITHER SIDE COLLAPSES UNDER FIRE CONDITIONS

FLAME RETARDANT

ANY COMPOUND OR MIXTURE WHICH WHEN APPLIED PROPERLY IMPROVES THE RESISTIVITY OR FIRE RESISTANCE QUALITY OF FABRICS AND OTHER MATERIALS