fixtures that require a 1 1/4" vent

A) res. bar sink, beer tap, cuspidor, dental unit, drinking fountain, lavatory.


B) bath tub, bidet, res./comm. disposal, res. dishwasher, floor drains, floor sinks, flushing rim sink, glass washer, laundry sink, mop sink, service sink, shower stall, res./comm. sink, sitz bath, urinal water closet, wash fountain.


C) res. clothes washer


D) comm. bar sink, comm. dishwasher, sump pump, comm. clotheswasher.

A) res. bar sink, beer tap, cuspidor, dental unit, drinking fountain, lavatory.

what size of fixture ventis required for a bathtubs, bidets, shower stalls, urinals, water closets, wash fountain?

A) 1 1/4"


B) 1 1/2"


C) 2"


D) 3"

B) 1 1/2"

what size of vent is required by disposals, res. dishwasher, glass washer?

A) 1 1/2"


B) 2"


C) 3"


D) 4"

A) 1 1/2"

what size vent is required for floor drains, floor sinks, flushing rim sinks, mop sinks, service sinks, sitz bath?

A) 1"


B) 1 1/4"


C) 1 1/2"


D) 2"

C) 1 1/2"

How many fixture units does a 1" vent 45' or less provide?

A) 0


B) 1


C) 2


D) 3

B) 1

How many fixture units does an 1 1/2" vent 60' or less provide?

A) 2


C) 3


B) 6


C) 8

C) 8

How many fixture units are provided by a 2" vent 120' or less?

A) 6


B) 12


C) 18


D) 21

C) 18

beer taps should be run _ when possible. (n1)

A) direct


B) indirect


C) verticle


D) horizontal

B) indirect

what fixtures may not require a vent?

A) floor drains, floor sinks, service sinks, shower stalls


B) floor drains, floor sinks, floor urinals, mop sinks


C) floor drains, floor sinks, mop sinks, shower stalls


D) floor drains, floor sinks, mop sinks, water closets

C) floor drains, floor sinks, mop sinks, shower stalls

How many fixture units will an 8" vent 750' or less provide?

A) 1296


B) 1492


C) 2500


D) 3500

D) 3500

How many fixture units will a 6" vent 510' or less provide?

A) 1019


B) 1296


C) 1463


D) 1603

B) 1296

How many fixture units will a 4" vent 300' or less provide?

A) 122


B) 244


C) 488


D) 976

B) 244

How many fixture units will a 3" vent 212' or less?

A) 27


B) 51


C) 72


D) 105

C) 72

only one _ _ may be vented through an 1 1/2"

A) floor drain


B) clothes washer


C) water closet


D) bidet

C) water closet

a bathroom grouping containing one water closet, one urinal, one lavatory requires a minimum vent of what size?

A) 1 1/4"


B) 1 1/2"


C) 2"


D) 3"

B) 1 1/2"