Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
33 Cards in this Set
- Front
- Back
SYSTEMS RELY ON THE BLEED AIR SYSTEM
|
AIR CONDITIONING / PRESSURIZATION
WING AND ENGINE TERMAL ANTI-ICING ENGINE STARTING HYDRAULIC RESERVOIR PRESS WATER TANK PRESS |
|
APU IS CAPABLE OF SUPPLYING BLEED AIR...
|
TWO PACKS ON THE GROUND
ONE PACK IN FLIGHT |
|
DO NOT OPERATE MORE THAN ONE PACK
|
FROM ONE ENGINE
|
|
WING BODY OVERHEAT TEST
|
HOLD FOR A MINIMUM 5 SECONDS
BOTH WING BODY OVERHEAT LIGHTS ILLUMINATED MASTER CAUTION LIGHT ILLUMINATED AIR COND SYSTEM ANUNCIATOR ILLUMINATED |
|
BLEED TRIP OFF
|
ILLUMINATED AMBER
EXCESSIVE ENGINE BLEED AIR TEMP OR PRESS MASTER CAUTION AIR CONDITION |
|
TRIP RESET SWITCH
|
RESETS:
BLEED TRIP OFF PACK ZONE TEMP LIGHT |
|
TRIP RESET SWITCH OPENS
|
ENGINE BLEED VALVE
PACK VALVE MIX VALVE |
|
RECIRCULATION FAN SWITCHES
|
12
2A |
|
THE PACK TEMPERATURE CONTROL VALVE
|
CONTROLS THE QUANTITIY OF WARM AIR THAT IS MIXED WITH THE COOL AIR DOWNSTREAM OF THE AIR CYCLE MACHINE
|
|
WITH THE PACK TEMPERATURE CONTROL VALVE
|
THE PACK SUPLIES AIR AT THE TEMPERATURE OF THE ZONE WITH THE LOWEST SET TEMPERATURE
|
|
PACK HIGH FLOW AUTOMATIC SWITCHING IS INHIBITED WHEN
|
THE AIRPLANE IS ON THE GROUND OR
IN FLIGHT WITH THE FLAPS EXTENDED |
|
AUTOMATIC SWITCHING TO HIGH AIR FLOW OCCURS
|
BOTH ENGINE BLEED AIR SITCHES ARE OFF
APU BLEED SWITCHES ARE ON REGARDLESS OF FLAP POSITION AIR / GROUND STATUS NUMBER OF PACK OPERATING |
|
MAXIMUM AIRFLOW WHEN THE APU IS THE ONLY SOURCE OF BLEED AIR
|
ON THE GROUND
APU BLEED AIR SWITCH IS ON EITHER OR BOTH PACK SWITCHES ARE POSITION TO HIGH |
|
IF A PRIMARY PACK CONTROL FAILS
|
THE AFFECTED PACK IS CONTROLLED BY THE STANDBY PACK CONTROL IN THE OPPOSITE CONTROLLER
|
|
A PRIMARY OR STANDBY PACK CONTROL FAILURE CAUSES
|
PACK
MASTER CAUTION AIR CONDITION |
|
IF BOTH PRIMARY AND THE STANDBY PACK CONTROLS FAIL FOR THE SAME PACK
|
THE PACK CONTINUE TO OPERATE WITHOUT CONTROL UNLESS EXCESSIVE TEMPERATURE CAUSE THE PACK TRIP OFF
|
|
THE TEMPERATURE SELECTOR RANGE
|
18 C - 30 C
|
|
THE RIGHT PACK CONTROLLER
|
PRIMARY CONTROLLER FOR THE FLIGHT DECK TRIM AIR VALVE AND THE LEFT PACK CONTROLLER IS THE SECONDARY CONTROLLER
|
|
BECAUSE THE PACKS SUPPLY AIR AT THE TEMPERATURE OF THE COLDEST ZONE
|
THAT ZONE DOES NOT NEED TRIM AIR AND RELATED TRIM AIR VALVE CLOSED
|
|
THE OVERBOARD EXHAUST VALVE IS DRIVEN OPEN
|
IF EITHER PACK SWITCH IS IN HIGH OR THE RIGHT CIRCULATION FAN IS OFF
|
|
ZONE TEMP
CONT CABIN |
INDICATES A DUCT TEMPERATURE OVERHEAT OR FAILURE OF THE FLIGHT DECK PRIMARY AND STANDBY TEMPERATURE CONTROL
|
|
ZONE TEMP
FWD CABIN AFT CABIN |
INDICATES DUCT TEMPERATURE OVERHEAT
|
|
ZONE TEMP
CONT CABIN MASTER CAUTION RECALL |
INDICATES FAILURE OF THE FLIGHT DECK PRIMARY OR STANDBY TEMPERATURE CONTROL
|
|
ZONE TEMP
FWD CABIN AFT CABIN MASTER CAUTION RECALL |
INDICATES FAILURE OF THE ASSOCIATED ZONE TEMPERATURE CONTROL
|
|
WHEN THE TRIM AIR SWITCH IS OFF
|
THE PACKS OPERATES INDEPENDENTLY
LEFT PACK FLIGHT DECK RIGHT PACK AVERAGE OFF FWD AND AFT CABIN |
|
CABIN PRESSURE CONTROLLER
|
8000 FEET AT THE AIRPLANE MAXIMUM CERTFIED CEILING OF 41000 FEET
|
|
DURING T/O ROLL
|
THE CABIN PRESSURIZES TO AN ALTITUDE OF 200 FEET BELOW THE AIRPORT ELEVATION
|
|
WHEN THE AIRPLANE DESCENDS FROM CRUISE ALTITUDE
|
CABIN ALTITUDE DESCEND TO 300 FEET BELOW THE PLANNED LANDING ELEVATION
|
|
AUTO FAIL LIGHT
|
LOSS OF DC POWER
CONTROLLER FAULT OUTFLOW VALVE CONTROL FAULT EXCESSIVE DIFFERANTIAL PRESSURE EXCESSIVE RATE OF CABIN PRESSURE CHANGE HIGH CABIN ALTITUDE |
|
SYSTEM SAFETY RELIEF DIFFERANTIAL PRESSURE
|
9.10 PSI
|
|
MAXIMUM ALOWABLE CABIN PRESSURE DIFFERANTIAL FOR T/O AND LANDING
|
0.125 PSI
|
|
DURING SINGLE PACK OPERATION WITH TRIM AIR SELECTED OFF
|
THE PACK ATTEMPTS TO PRODUCE AN AIR TEMPERATURE TO SATISFY THE AVERAGE TEMPERATURE OF ALL THREE ZONES
|
|
IF ALL TEMPERATURE SELECTORS ARE POSITIONED TO OFF
|
LEFT PACK MAINTAIN FIXED 24 C
RIGHT PACK MAINTAIN FIXED 18 C |