Friability Test: Acceptance criteria of uncoated tablet |
Not more than 1% |
|
|
Friability Test: Acceptance criteria of conventional compressed tablets |
0.5% — 1% |
|
|
Apparatus used for friability test |
Roche friabilator |
|
|
4 apparatus that can be used for hardness test |
Monsanto hardness Pfizer Erweka tester Schleuniger |
MPES |
|
Apparatus used in thickness test |
Vernier caliper |
|
|
Disintegration Test: The tablet distance must be ____ at a frequency of ___ per ___ |
5-6 cm 28-32 cycles Minute |
|
|
Disintegration limit for uncoated tablet |
15 minutes |
|
|
Disintegration limit for enteric coated tablet |
3 hours |
|
|
Disintegration limit for dispersible table |
3 minutes |
|
|
Disintegration limit for effervescent tablet |
Less than 3 minutes |
|
|
Disintegration limit for sublingual tablet |
4 hours |
|
|
2 apparatus used for dissolution test |
Basket Paddle |
|
|
The requirement for weight variation must be within the limits of ____ to ____ of the average weight |
90% 110% |
|
|
Acceptance criteria of weight variation of capsule less than 300mg is ____ while for 300mg and more is ____ |
10% 7.5% |
|
|
Acceptance criteria for tablets less than 80mg is |
10% |
|
|
Acceptance criteria for tablets weighing 80mg to 250mg is |
7.5% |
|
|
Acceptance criteria for tablets more than 250mg is |
5% |
|
|
Ha |
Ha |
|