Aircraft Oxygen Systems fall into what two categories?

Gaseous

Liquid
Gaseous Oxygen falls into what three categories?
Low Pressure (0-500 psig)

High Pressure (0-1800 psig)

Reduced High Pressure
Gaseous Oxygen Systems are used in what type aircraft?
Multiplace aircraft where space and weight considerations are less important items
What type aircraft are Liquid Oxygen Systems used in?
Aircraft where space and weight consideration is paramount
Liquid oxygen systems consist of what parts?
Converter
Filler valve
Heat exchanger
Control valve
Releif valve
Tubing
Regulators and other cockpit instruments
Diluter Demand Type Regulators are used in some aircraft with what systems?
Gaseous Oxygen Systems
By placing the diluter lever knob to the normal position, an air-oxygen mixture is supplieds upon demand up to what alttitude?

A) 32,000-45,000 feet
B) 28,000-32,000 feet
C) 25,000-32,000 feet
B) 28,000-32,000 feet
At approximately _________ feet ambient air is shut off, and the user receives 100% oxygen?

A) 25,000 feet
B) 45,000 feet
C) 31,000 feet
D) 32,000 feet
D) 32,000 feet
Automatic Positive Pressure Diluteer Demand Regulators are used in aircraft with what type systems?

A) Gaseous
B) Liquid
C) Gaseous or Liquid
C) Gaseous or Liquid
Positive Pressure Regulators at 28,000-32,000 feet are the same as what regulator?
Diluter Demand Regulator
Above what alttitude does the Positive Pressure Diluter Regulator add oxygen at a posiutive pressure to the mask?

A) 25,000 feet
B) 30,000 feet
C) 35,000 feet
D) 40,000 feet
B) 30,000 feet
Service ceiling of the Positive Pressure Diluter Regulator is what altrittude?

A) 40,000 feet
B) 45,000 feet
C) 50,000 feet
D) 55,000 feet
C) 50,000 feet
Pressure Diluter Regulator shall not be used above what altittude except for short periods?

A) 40,000 feet
B) 42,000 feet
C) 43,000 feet
D) 44,000 feet
C) 43,000 feet
Miniature Regulators do what?
reduce and regulate supply pressure, and deliver 100% oxygen
A safety feature on the Mini Regulator automatically maintains a pressure of what amount?

A) 0 to 2.5 H2O at all altitudes up to and including 34,000 feet
B) 0 to 2.5 H2O at all altitudes up to and including 35,000 feet
C) 0 to 2.5 H2O at all altitudes up to and including 54,000 feet
0 to 2.5 H2O at all altitudes up to and including 34,000 feet
In the mini Regulator the pressure breathing feature maintains a positive pressure in the mask of up to what?

A) 20.0 in H2O at altitudes between 30,000 and 50,000 feet
B) 20.0 in H2O at altitudes between 35,000 and 50,000 feet
C) 20.0 in H2O at altitudes between 35,000 and 505000 feet
20.0 in H2O at altitudes between 35,000 and 50,000 feet
Miniature Regulators can be used up to how many feet?

A) 41,000
B) 43,000
C) 45,000
43,000
Only oxygen conforming to ________ shall be used in aircraft gaseous oxygen systems.

A) MIL-PRF-27312 Type I
B) MIL-PRF-27210 Type I
C) MIL-PRF-27215 Type I
MIL-PRF-27210 Type I
How can you identify Aviator oxygen supply cylinders?
Green
3 in white band around upper cylinder
What shall be stenciled in white letters 1 3/4 to 2 in high
OXYGEN AVIATORS
Pressure in oxygen cylinders shall not fall below what amount?

A) 50 psig
B) 55 psig
C) 60 psig
50 psig
All cylinders which have a pressure below _______ shall be removed from service for vacuum and heat drying/hot nitrogen gas drying

A) 5 psig
B) 10 psig
C) 15 psig
15 psig
Hydrostatic test interval for P3 fixed installed oxygen cylinders shall not exceed ______ years.

A) 4
B) 5
C) 8
8
Never refill a cylinder that has reached what?
5 year hydro test
Always assume that frosted or uninsulated lines are at what temp?

A) -197 degrees F
B) -235 degrees F
C) -297 degrees F
-297 degrees F
One volume of liquid oxygen will expand to ______ volumes of gaseous oxygen. If this happens in confined space it can explode.

A) 10,000
B) 11,000
C) 12,000
12,000
Only liquid oxygen conforming to ___________ shall be used in aircraft liquid oxygen systems.

A) MIL-PRF-27211 TYPE II
B) MIL-PRF-27210 TYPE II
C) MIL-PRF-27205 TYPE II
MIL-PRF-27210 TYPE II
LOX storage shelves shall not be less then ______ high and no less then _______ deep?
17 inch

18 inch
LOX shelters shall be painted what color with what color reflective tape?
white paint

green tape
Letters on LOX shelter shall be no less then _________ high.
2 inch
Purge oxygen systems with what?

A) oil free nitrogen type II class I Grade B
B) oil free nitrogen type I class II Grade B
C) oil free nitrogen type I class I Grade B
oil free nitrogen type I class I Grade B
Oxygen test stands and purging equipment use only nitrogen from what color cylinders and marked with what?
gray paint

NITROGEN OIL FREE in white letters

Two 3-in wide black bands
When purging oxygen systems you pass a maximum pressure ___________psig and a minimum temp of _______ degrees for _____ min.
120 psig
90oF
30 Min
Inspections on LOX converters are done how often?
231 days
ARO Lox converters are purged at ambiant temp for a period of ______-min.

A) 50
B) 60
C) 70
60
Oxygen shops should be kept at what temp?
65-75F
Oxygen is about_________ times densor then air?

A) 5%
B) 10%
C) 15%
10%
Oxygen shops shall be exausted how often for shore and how often for ship
3 per hour shore

2 per hour ship