What lube is used on umbilical fittings? |
DO NOT, use lube just clean fresh water only. |
|
Umbilical Proof test is conducted to what pressure? |
200% Max system Operating pressure. |
|
What is Operating Pressure for breathing air is? |
250 PSIG |
|
What is used for a test medium for DLSS hoses? |
filtered tap water |
|
What amount of dead weight is used for umbilical hydro test? |
200lbs |
|
If hose creeps on umbilical hydro more than ___it is unacceptable. |
1/16 inch |
|
What must be done prior to putting a hose in service after Hydro test? |
Clean with NID and water then flush with fresh water to rinse all soap from hose. |
|
Umbilical test tag must contain? |
Manufacture, Date of manufacture, test activity, test pressure, and date. |
|
Umbilical Comms resistance (OHMS) |
1 Ohm per 100ft
|
|
Umbilical D-ring dead weight test "LBS" |
500 LBS |
|
Umbilical D ring seized with? |
3/16 nylon cord must be used. |
|
Umbilical strength member separation distance? First 50 and beyond? |
First 50' 12 to 18 inches 50' and beyond 36 inches max separation. |