What lube is used on umbilical fittings?

DO NOT, use lube just clean fresh water only.

Umbilical Proof test is conducted to what pressure?

200% Max system Operating pressure.

What is Operating Pressure for breathing air is?

250 PSIG

What is used for a test medium for DLSS hoses?

filtered tap water

What amount of dead weight is used for umbilical hydro test?

200lbs

If hose creeps on umbilical hydro more than ___it is unacceptable.

1/16 inch

What must be done prior to putting a hose in service after Hydro test?

Clean with NID and water then flush with fresh water to rinse all soap from hose.

Umbilical test tag must contain?

Manufacture, Date of manufacture, test activity, test pressure, and date.

Umbilical Comms resistance (OHMS)

1 Ohm per 100ft


Umbilical D-ring dead weight test "LBS"

500 LBS

Umbilical D ring seized with?

3/16 nylon cord must be used.

Umbilical strength member separation distance? First 50 and beyond?

First 50' 12 to 18 inches


50' and beyond 36 inches max separation.