13 Cards in this Set

  • Front
  • Back
Where are the ship drawing index (SDI) maintained?
In the ships log room or technical library. It lists all the drawings applicable to that ship.
Who is the sole provider of U.S. Navy ship fitted ICCP systems?
Electrocatalytic, Inc.
What NSTM chapter covers Cathodic protection?
NSTM Chapter 633
What records and reports, maintained in the ships log room, often provide important information on ICCP system components?
U/W repair/working reports
ship maintenance/repair records
u/w hull inspection reports
u/w hull cleaning reports
diver hull inspection data sheet (NAVSEA Form 4730/7)
A ship check is required to establish liason with whom?
Ships Engineering Officer and the work center with responsibility for the ICCP system
If the anode of a reference cell gland assembly is located in an enclosed compartment, what requirement must be considered?
Obtaining gas-free access IAW NSTM 074 Vol 3 section 20
What are the 2 anode replacement procedures?
Dry procedure
Wet procedure
How is the dry procedure conducted and what kind of epoxy does it use?
It's conducted in a dry habitat that permits the use of epoxy capastic
Of the two procedures to repalce anodes, which procedure is more costly in both time and expense?
The dry procedure
Approximately how much time does constructing and fitting of a habitat add to the repairs of a anode replacement?
48 hours
Underwater epoxy is unlikely to be applied successfully if the ambient temperture is below ____ degrees.
50 degrees
How long does it take to replace a anode,
Wet procedure?
Dry procedure?
Wet: 2-3 days
Dry: 4-5 days
How long does it take to replace,
Reference Cells?
Dielectric shields?
1-2 reference cells in 2 days, dependent on the extent of damage.