TD is a collective term that includes what four types of technical issues?

Formal Change, Interim Change, Bulletin and Rapid Action Minor Engineering Change (RAMEC)

RAMEC stands for what

Rapid Action Minor Engineering Change

TD that directs the accomplishment and recording of a configuration change?

Formal Change

TD by message or message format letter when enclosures are required?

Interim Change

directs a ONE-TIME inspection to determine whether a given condition exists and what action shall be taken if the condition is found.

Bulletin

Rapid Action Minor Engineering change

Directs the accomplishment and recording of a minor configuration change

Describes the management and procedures functions of the NAVAIR RAMEC TD system

NAVAIR 00-25-300

Four categories of TDS are assigned in accordance with the importance and urgency of accomplishing the work involved

Immediate Action, Urgent Action, Routine Action, and Record Purpose.

this category shall be used when an uncorrected, unsafe condition exists which could result in fatal or serious injury to personnel; or extensive damage to or destruction of valuable property.

Immediate action

this category shall be issued under the governing factors of combat necessity or potential hazardous conditions that could result in injury to personnel, damage to valuable property or unacceptable reductions in operational readiness.

Urgent

This category shall be issued for conditions that embody degrees of risk calculated to be acceptable within broad time limits

Routine

assigned to Formal Change TDs issued to document configuration changes that have been incorporated in all affected equipment by the change designer/originator before the TD is issued.

Record Purpose

Clarifies, Corrects, Adds to, Deletes from, Makes minor changes, Extends a target completion date, or cancels an existing TD,

Amendment

a completely new edition of an existing TD

Revision

the normal process by which TDs are moved from active D files to the history TD files when records show all compliance have been accomplished.

Completion (formerly rescission)

the process by which and issued/published TD is removed from active files upon issue of a superseding TD

Supersedure

terminates compliance requirements and removes TDs from the active files

Canellation