Sprinkler heads should be |
The same type |
|
Solenoid valves are shut off at |
Control panel |
|
The number of heads is determined by static pressure and |
Their flow rates of head |
|
Sprinkler systems use what voltage |
Low voltage 24V |
|
To prevent back syphonage in commercial installations what must be installed |
A DCVA or RP if chemicals are used |
|
To protect lines from freezing they should be |
Graded to a drain or blown out with compressed air |
|
Which heads should be used with a flower bed |
Bubbler |
|
The most common piping used is |
PVC Polyethylene |
|
To prevent the system from turning on use a |
Rain water sensor |
|
Impulse heads have a radius of |
15 to 20ft |
|
Lines for commercial installation should be buried at between |
12-18in |
|
To prevent backflow on residential installations what should be installed |
Double check valve |
|
Control valves maybe either |
Manual Electronic |
|
Polyethylene pipe should be a minimum series |
Series 75 |
|
Joining methods can be either |
Insert fittings and clamps Mechanical joints |
|
The bury depth for residential piping is |
6-12in |