SENSITOMETRIC TESTING SHOULD BE PERFORMED EVERY
WEEK
SPEED AND CONTRAST VALUES MEASURED DURING SENSITOMETRIC TESTING SHOULD NOT VARY MORE THAN HOW MUCH FROM THE BASELINE
10%
SPEED STEP USED DURING SENSITOMETRIC TESTING IS THE STEP CLOSEST TO WHAT DENSITY VALUE
0.25
A MALFUNCTION IN WHICH THE DEVELOPER TEMPERATURE RUNS TOO HIGH WILL CAUSE
GREASY FILM
A MALFUNCTION IN WHICH THE DEVELOPER REPLENISHMENT RUNS TOO HIGH WILL CAUSE:
GREASY FILM
A MALFUNCTION IN WHICH THERE IS A WHITE LIGHT LEAK INTO THE PROCESSING ROOM WILL CAUSE:
MILKY FILM
POOR FIXER REPLENISHMENT WILL CAUSE:
GREASY FILM
A MALFUNCTION IN WHICH THERE ARE DARK FLAKES IN THE WASH WATER IS CAUSED BY:
ALGAE IN THE WASH WATER
USE OF OUTDATED FILM WILL CAUSE
DARK FILM
A MALFUNCTION IN WHICH FIXER SOLUTION HAS ENTERED THE DEVELOPER TANK WILL CAUSE:
MILKY FILMS
IN WHICH SECTION OF THE PROCESSOR ARE UNEXPOSED SILVER HALIDE CRYSTALS WASHED OUT OF THE EMULSION?
FIXER
IN WHICH SECTION OF THE PROCESSOR IS THE EMULSION SEALED?
DRYER
IN WHICH SECTION OF THE PROCESSOR IS THE TEMPERATURE SET FROM 90 - 105 DEGREES FERENHEIT DEPENDING ON THE TYPE OF CHEMISTRY BEING USED?
DEVELOPER
WHICH OF THE FOLLOWING SYSTEMS MOVES THE FILM AND AGITATES THE CHEMISTRY?
RECIRCULATION
WHICH OF THE FOLLOWING SYSTEMS PROVIDES FRESH CHEMISTRY TO PROCESS EACH FILM?
REPLENISHMENT
WHICH OF THE FOLLOWING SYSTEMS REMOVES REACTION PARTICLES FROM THE DEVELOPER SOLUTION BY SENDING IT THROUGH A FILTER?
RECIRCULATION
THE SETTING ON WHICH OF THE FOLLOWING SYSTEMS IS DETERMINED BY THE AVERAGE NUMBER OF 14X17 INCH FILMS FED THROUGH THE PROCESSOR IN A TYPICAL WORKDAY?
TRANSPORT
WHICH OF THE FOLLOWING GRID ERRORS WILL RESULT IN AN IMAGE THAT SHOWS NORMAL DENSITY IN THE MIDDLE BUT DECREASED DENSITY ON THE SIDES, ASSUMING THE CORRECT SIDE OF THE GRID FACES THE X-RAY TUBE?
LATERAL DECENTERING
WHICH OF THE FOLLOWING GRID ERRORS WILL RESULT IN AN IMAGE THAT SHOWS DECREASED DENSITY MORE TO ONE SIDE THAN THE OTHER?
UPSIDE DOWN
GRID RATIO IS DESCRIBED BY WHICH OF THE FOLLOWING?
H/D
GRID RADIUS IS DESCRIBED AS:
THE NUMBER OF LEAD STRIPS PER INCH OR CENTIMETER
THE ASPECT OF A FILM-SCREEN SYSTEM THAT MAY BE EXAMINED BY CONDUCTING A WIRE MESH TEXT IS THE:
PROTECTIVE LAYER
THE PORTION OF AN INTENSIFYING SCREEN THAT HELPS PREVENT DAMAGE FROM SCRATCHING IS THE:
REFLECTIVE LAYER
THE PORTION OF AN INTENSIFYING SCREEN THAT IS MADE OF POLYESTER IS THE:
BASE
A FASTER FILM-SCREEN SYSTEM WILL EXHIBIT:
DECREASED DENSITY
A SLOWER FILM-SCREEN SYSTEM WILL EXHIBIT:
POORER RECORDED DETAIL
THE SECTION OF AN H & D CURVE THAT REPRESENTS BASE PLUS FOG IS THE:
BODY
THE SECTION OF AN H & D CURVE THAT REPRESENTS D-MAX IS THE:
BODY
THE SECTION OF AN H & D CURVE ON WHICH EXPOSURE IS PLOTTED IS THE:
BODY
THE FUNCTION OF THE BLUE TINT ADDED TO THE FILM'S BASE IS TO:
INCREASE RECORDED DETAIL
AS KVP IS INCREASED:
CONTRAST INCREASES
AS KVP IS DECREASED:
RECORDED DETAIL DECREASES
WHICH OF THE FOLLOWING SETS OF EXPOSURE FACTORS WILL PRODUCE THE RADIOGRAPH WITH THE BEST RECORDED DETAIL?
30 MAS, 92 KVP, 40-INCH SID, 4-INCH OID
WHICH OF THE FOLLOWING SETS OF EXPOSURE FACTORS WILL PRODUCE THE RADIOGRAPH WITH THE HIGHEST CONTRAST?
15 MAS,100 KVP, 40-INCH SID, 4-INCH OID
WHICH OF THE FOLLOWING SETS OF EXPOSURE FACTORS WILL PRODUCE THE RADIOGRAPH WITH THE MOST MAGNIFICATION?
60 MAS, 80 KVP, 40-INCH SID,4-INCH OID
TRUE OR FALSE WHEN KVP IS INCREASED, THERE IS AN INCREASE IN THE NUMBER OF PHOTOELECTRIC INTERACTIONS THAT OCCUR:
TRUE
TRUE OR FALSE,LOW KVP=LOW CONTRAST= LONG SCALE CONTRAST=MANY GRAY TONES
TRUE
DIFFERENTIAL ABSORPTION OF THE X-RAY BEAM PRODUCES:
CHARACTERISTIC RADIATION
BEAM RESTRICTION HAS THE FOLLOWING EFFECT ON CONTRAST:
NO EFFECT ON CONTRAST