What is the minimum accumulator pressure for starting APU?
|
2,650 PSI
|
|
What is the APU fuel consumption rate?
|
150 lbs per hour
|
|
The APU is monitored and controlled by?
|
ESU
|
|
To maintain BIT codes after failure, what power is required and what position must the APU control switch be in?
|
DC power and switch is in the On position
|
|
At what PSI does the ACCUM LOW advisory appear?
|
2,650 PSI
|
|
Pressurized fuel is supplied from which fuel tank.
|
Left fuel tank
|
|
What switch when placed in the ON position initiates the the APU start sequence?
|
APU CONTR switch
|
|
What switch when placed in the ON position makes electrical power available?
|
APU GENERATOR
|
|
How many seconds will the backup pump stay on once it has been cycled to the OFF or AUTO position?
|
90 seconds
180 seconds with winterization kit installed |
|
When will the ACCUM LOW advisory light extinguish?
|
Once the accumulator is recharged
|
|
What action must be taken when the APU does not start and the APU ACCUM LOW advisory light is not illuminated?
|
A start may be attempted by simultaneously moving the APU CONTR switch to ON and actuating the manual START/OVERRIDE lever located on the accumulator manifold
|
|
What are the four segment lights that monitor APU operation?
|
APU ON, APU FAIL, APU OIL TEMP HI, and APU ACCUM LOW
|
|
What kind of faults could occur when the APU FAIL light illuminates?
|
High Ng, Low Ng, High TGT, Low TGT, low oil pressure, or start sequence failure
|
|
What does the APU OIL TEMP HI indicate?
|
The APU has reached the maximum oil temperature for continuous operation
|
|
The ESU displays APU faults by using what indicators?
|
Built in Test (BIT)
|
|
How long must you wait to check the APU oil level?
|
1 hour after APU shutdown
|
|
Where is the APU oil supply contained?
|
In the APU gearbox oil sump
|
|
Why does the backup pump have a limited operating time when the rotor system is static?
|
To prevent hydraulic fluid overheating
|
|
What is the operating time and cool down time for the backup hydraulic pump when the outside air temperature (OAT) is 33 to 38 degrees C?
|
24 on, 72 off
|
|
What is the operating time and cool down time for the backup hydraulic pump when the outside air temperature (OAT) is 39 to 60 degrees C?
|
16 on, 48 off
|
|
How long can you operate the APU if the APU exhaust is less than 15 feet from the nearest aircraft or object?
|
None, you cannot operate the APU.
|
|
How long can you operate the APU if the APU exhaust is 15-20 feet from the nearest aircraft or object?
|
3 minutes
|
|
How long can you operate the APU if the APU exhaust is 20-30 feet from the nearest aircraft or object?
|
10 minutes
|
|
How long can you operate the APU if the APU exhaust greater than 30 feet from the nearest aircraft or object?
|
Unlimited-ambient temperature is less than 60 degrees celsius
|
|
What must be done if the APU FIRE light illuminates?
|
Pull APU t-handle
Confirm fire Fire Extinguishing switch to RESERVE-MAIN if available Fire Extinguisher as required FUEL PUMP swich OFF APU CONTR switch OFF |
|
How long must you wait after APU shutdown before attempting restart?
|
2 minutes
|
|
What must be done if the APU FAIL light comes on?
|
Do not secure battery or APU CONTR switches
Check ESU BIT indicators Restart APU by resetting BATT and APU CONTR swtiches |
|
What must be done if the APU GEN light comes on?
|
Put APU GENERATOR switch to RESET, then ON
IF CAUTION REMAINS Put APU GENERATOR switch to OFF |
|
What must be done if the APU OIL HOT light comes on?
|
APU CONTR/CTRL switch OFF
|
|
After shutting down due to APU OIL HOT light comes on, how long must you wait to restart the APU?
|
60 minutes
|