load of 1 outlet
|
90 watts
|
|
wall outlet mounting height
|
300 mm affl, above tables: 900mm affl
|
|
standard mounting height of switches
|
1.35-1.4m
|
|
branch circuits should be able to supply a load of
|
30 watts per sqm
|
|
1 coulomb
|
6.25 x 10^18 electrona
|
|
number of outleta in a circuit
|
6 for 15amos, 8 for 20 amps
|
|
1 horsepower
|
746 watts
|
|
heat detector rating inbordinary rooms, in kitchens
|
135f and 190-200f
|
|
fire suppression system for rooms with sensitive equipment. ex. server room
|
fm-200
|
|
aircon filtser for hospitals
|
hepa filter or high efficiency particulated filter
|
|
accu
|
air cooled condensing unit
|
|
ton of refrigeration
|
12000BTU/hr = 3.517kW = 4.7 hp
|
|
comfortable cooling range
|
68-74 f = 20-23.33 c
|
|
covert c to f
|
f = c x 9/5 + 32
|
|
dumbwaiter details
|
max 277kg max 1.2ht max 3 storeys
|
|
escalator details
|
w= 32 or 48 in. 30deg (35 max as per nbc) incline speed= 90 & 120 fpm
|
|
escalator landing length
|
4' 8' 10'
|
|
vermaport details/ moving sidewalk
|
0-5 deg incline 27"&29" 300-400' max length considered moving ramp id at least 15 deg
|
|
vermaport details/ moving sidewalk
|
0-5 deg incline 27"&29" 300-400' max length considered moving ramp id at least 15 deg
|
|
unit of light or luminius flux
|
lumens
|
|
unit of density of light
|
footcandle = 10.76lux
|
|
unit of light intensity
|
candlepower candela
|
|
brightness
|
footlambert
|
|
filament lamps
|
incandescent, tungsten-halogen
|
|
gaseous discharge
|
fluorescent, neon vapor
|
|
high intensity discharge
|
mercury vapor, metal halide, hps lps
|
|
dieect lighting
|
99-100% directed downwards
|
|
semi-direct lighting
|
60-90% directed downwards 10-40% directed upwards
|
|
general diffuse or dorect-indirect lighting
|
50-50%
|
|
semi indirect lightinf
|
60-90% directed upwards 10-40% directed downwards
|
|
indirect lighting
|
90-100% directed upwards
|
|
casual work fc lux
|
10-30 fc x10.76 for lux
|
|
moderate work fc lux
|
30-50 fc x 10.76 lux
|
|
prolonged work fc lux
|
50-100 fc x 10.76 lux
|
|
precision work fc lux
|
100-150 fc x 10.76 lux
|
|
fine precision work
|
150-200 fc x 10.76 lux
|
|
normal hearing range
|
20hz to 20khz
|
|
speed of sound
|
344m/s 1240kph 770mi/h
|
|
t wire
|
thermoplastic
|
|
tw wire
|
moisture resistant thermoplastic
|
|
thhn
|
heat resistant thermoplastic nylon insulation
|
|
thw
|
thermopladtic heat reaistant moisture resistant
|
|
thwn
|
moisture and heat resistabt thermoplastic nylon insulation
|
|
ac cable
|
armored cable
|
|
mc cable
|
metal clad cable
|
|
mi cable
|
mineral insulated
|
|
nm cable
|
non metallic sheathed cable "romex"
|
|
snm cable
|
shielded non metallic cable
|
|
se or use cable
|
service entrance or undergeound service entrance
|
|
tc cable
|
power and control tray cable
|
|
fc cable
|
flat cable assemblies
|
|
fcc cable
|
flat conductor cable
|
|
mv cable
|
medium voltage cable
|
|
limit wiring length to __ mts to avoid voltage drop
|
35m
|
|
demand load factor
|
0.80
|
|
light outlet load
|
100w
|
|
f 20 t 12 ww
|
fluoreacent 20 watts tubular 12/8" diameter warm white
|
|
h38 mp 100dx
|
mercury lamp #38 mp lamp ballast numer 100 watts dx phosphors
|
|
mounting height ratio =
|
spacing/mounting heigt
|
|
normal hearing range
|
20hz to 20khz
|