Plans and specifications require critical review by the: |
- owner to check all the subcontractors - owner to check all the material suppliers - contractor and owner to establish all the payment schedules - contractor and owner to establish an agree ment on the work descriptions |
|
|
How much start up capital is needed to start a new contracting business? |
$ 1,000. $2,500. $5,000. $12,000. |
$2,500. |
|
To whom should a Misc-1099 be sent? |
- to all corporations receiving mor e t han $600 during a cale ndar year - to all employees, regardless of how m uch t hey earnto all employees earning over $600 during a calendar yearto a subcont ractor earning over $600 during a cale ndar year |
|
|
What is the correct way to use a roto- or hammer -drill?
|
slow speed with light pressure
fast speed with light pressure slow speed with fim1 pressure fast speed with as much pressure as you can manage |
slow speed with firm pressure
|
|
What minimum thickness of plywood is recommended for phone room backboards? |
3/8"
1/2" 3/4" 7 /8" |
3/4"
|
|
What is the minimum bending radius for fiber optic cables? |
2 times the cable diameter
10 times the cable diameter 20 times the cable diameter 40 times the cable diameter |
20 times the cable diameter
|
|
What DC voltage should you set a megger to when testing the insulation of a wire? |
the same as the circuit voltage
slightly less than the normal peak AC the same as voltage rating of the insulation a slightly higher DC voltage than the AC peak voltage. |
a slightly higher DC voltage than the AC peak voltage.
|
|
When measuring conduit for two 90° bends, you should: |
add the back-to-back overshoot to the desired length
subtract the back-to-back overshoot to the desired length divide the desired length by the back-to-back overshoot divide the back-to-back overshoot by the desired length |
add the back-to-back overshoot to the desired length
|
|
Which of the following standards covers fire alarms? |
NEC770
NEC650 TlA/ElA-607 NFPA 72 |
NFPA 72
|
|
What is the most practical alternative for running conductors between floors of an existing building? |
conduit
sleeve protective insulating material around conductors run along the outside |
conduit
|
|
When designing and drawing a low voltage system: |
draw on the existing electrical plan
draw on new plans present as a list, rather than diagram use a different color |
draw on new plans
|
|
Two technicians are installing a data cable on one end. You connect the tracer at the office and the other at the block, but you do not get a signal. What should you conclude? |
there is a short in the cable
you connected the cable wrong you used the wrong cable cable is cut |
you used the wrong cable
|
|
Of the following, which is the strongest part of your body? |
lower back
lower side mid chest upper back, near the shoulders |
upper back, near the shoulders
|
|
Please refer to the drawing of a spade bit below. Which of the following angles, if ithere, should be maintained when sharpening the bit to get maximum usage |
Maintain both
Maintain one |
Maintain Both
|
|
For a chime/bell system in a residence, it is standard practice to install: |
one pushbutton for the whole system
one pushbutton at each door two push buttons for the whole system three pushbuttons for the whole system |
one pushbutton at each door
|
|
What are the general wiring requirements for a 70-volt background-music sound system? |
one pair of No. 14 AWG wires
one pair of No. 16 AWG wires one pair of No. 18 AWG wires one pair of No. 22 AWG wires |
one pair of No. 22 AWG wires
|
|
How long can a single run of multimode fiber typically be? |
100 Ill
200m 500m 2km |
500m
|
|
Which would you use to clear or check conduit before pulling wire through |
mandrel
auger fish tape Roto-Rooter |
mandrel
|
|
What type of switch is normally used to control a remote control relay? |
Multi-pole pushbutton
Two-position rocker Double pole, single throw, momentary (DPST) Single pole, double throw (SPOT) |
Single pole, double throw (SPOT)
|
|
What is the proper way to store tools at a job site? |
tools should not be left at the job site
any cover to keep tools from getting wet is adequate power tools left at the job site must be double-locked power-actuated tools must be kept in a locked container whenever unattended |
power-actuated tools must be kept in a locked container whenever
unattended |
|
What section of the NEC covers communication circuits? |
650
770 800 900 |
800
|
|
What does an octagon with a number in it signify on an electrical plan diagram? |
clock system component, with number indicating the component type
plan diagram cross-reference connection to another point on diagram low voltage switch with pilot light |
clock system component, with number indicating the component type
|
|
What is the typical maximum pulling tension for indoor fiber optic cables? |
2Sibs
50lbs 100lbs 600lbs |
100 Lbs
|
|
For low-voltage wiring, use rigid metal conduit to go through ______ for fire protection. |
wood joists
drywall concrete walls plaster walls |
concrete walls
|
|
In what range of voltages does a Megger operate? |
0-250
200-600 500- 1000 500-5000 |
500- 5000
|
|
Where does the blue wire go in the low-voltage system? |
to a switch
to a relay to a switch and a relay to the 120-V supply |
to a relay
|
|
According to NFPA standards, when installing a fire-alarm panel and other devices attached to the panel: |
all components must be purchased at the same time
all devices being attached must be UL-approved for the panel all devices must be approved by the authority having jurisdiction or listed for use with the panel any suitable device, equivalent to a listed device, may be used |
all devices must be approved by the authority having jurisdiction or listed
for use with the panel |
|
What is the maximum length of a run of single mode fiber? |
200 m
500 m 20 km 80 km |
80km
|
|
How do you first test fiber? |
OTOR
HeNe or LEO laser (visible light) mode stripper mandrel |
HeNe or LED laser (visible light)
|
|
What tool would you use to check that a pipe is adequately grounded? |
Megger
Wiggy Ammeter Ouija board |
Megger
|
|
You must use conduit when running wiring through: |
cement
drywall wood timbers plaster |
Cement
|
|
What tool would you use to notch wooden studs, floor joists, etc., for the passage of conduit? |
drill
hacksaw wood chisel keyhole saw |
wood chisel
NOTCH |
|
What type of light pulses travel in singlemode fiber optic cables? |
low order only
high order only both high and low order digital light |
low order only
|
|
When using a keyhole saw, you should use: |
very light pressure
medium pressure heavy pressure reverse pressure |
very light pressure
|
|
You insert telephone line tester into a wall jack so the number 2 is opposite the stepped side of the j ack. The yellow light goes on. This tells you… |
the jack is wired correctly
the polarity is reversed in line 1 the polarity is normal in line 2 there is AC power on the line |
there is AC power on the line
|
|
A device has a resistance of 12 ohms and draws 3 amps. According to Ohm's Law, what voltage should be supplied? |
3V
6V 36 v 120 v |
36V
|
|
Conductor length and conductor size are both proportionally related to: |
resistance
impedance capacitance attenuation |
Resistance
|
|
What is the current in this circuit? |
2.1 amps
4.0 amps 7.0 amps 12.0 amps |
12.0 amps
|
|
|
downward connected var iable |
direct current voltage |
|
What material would you drill with a standard high speed steel drill bit? |
sheet metal
masonry tile wood |
sheet metal (Steel Bit)
<> masonry (Carbine) tile (Diamond) wood (spade) |
|
If a phone system is ringing on the main line, what is the color of the ring wire? |
green
yellow red black |
Red (1st RING)
Green (1st TIP) <> Yellow (2ndRING) Black (2ndTIP) White (3rd Ring) Blue (3rd TIP) |
|
Bending conduit is best done with a: |
field hickey
field hockey field hooey finial |
field hickey
|
|
According to NFPA 71, a central station must have at least ______________ person(s) to assure immediate attention to fire-alarm signals received. |
1
2 3 The number doesn't matter. |
2
|
|
In an local antenna system, everything after channel 14 and up is called: |
VHF
UHF mid high super high |
UHF (Ultra High Frequency)
<> VHF (Very High Frequency) |
|
How do you measure the length of fiber on a spool? |
OTOR
ruler mechanical reel count the tun1s around the spool |
OTDR (optical time-domain reflectometer)
|
|
So und system cables are allowed to fill a raceway to _ _______of its capacity? |
100%
90% 750/o 60% |
75%
|
|
Please refer to the diagrams of three different screwdrivers shown below. Which of the following, if any, is an "electrician's tip" or "cabinet tip" screwdriver? |
figure A
figure B figure C none of the above |
figure C
|
|
According to NFPA standard s, if any work is begun on the alarm panel of a central station, you must: |
first test the contact closures
notify the alarm company in advance test all devices on the circuits restore the panel to normal operation as soon as possible. |
restore the panel to normal operation as soon as possible.
|
|
How many wires does a typical 66-block hold? |
25
so 66 100 |
100
|
|
What color are 568SC connectors and adapters for singlemode fiber? |
red
green beige blue |
Blue
|
|
Which bit is best for drilling deep holes? |
single-twist bit
double-twist bit masonry none of the above |
single-twist bit
|
|
How should you install vertical cables in a multistory building? |
start at the top and pull down, then tie from the bottom up
start at the top and pull down, then tie from the top down start at the bottom and pull up, then from the tie bottom up start at the bottom and pull up, then tie from the top down |
start at the top and pull down, then tie from the top down
|
|
What seismic zone(s) are in California? |
1
2 3 3&4 |
3 & 4
|
|
What is the maximum pulling tension for CAT 5 cables? |
25
50 100 600lbs |
100?
|
|
What type of light pulses travel in multi mode fiber optic cables? |
low order only
high order only both high and low order digital light |
both high and low order
<> Low Order Only (SINGLE MODE) |
|
If you have a 120-V, 20-A circuit on which three 150-W incandescent bulbs, one 250-W television, and one 45-W VCR are installed, can you add a 1200-W heater without overloading the circuit? |
No.
Yes. The current will be 6.4 amps. Yes. The current will be 16.2 amps. Yes. The current will be 18.9 amps. |
Yes. The current will be 16.2 amps.
|
|
Bridge clips are used: |
to bridge and ground a punch panel
to bridge and ground a 110-block to bridge two sides of a parallel-connected 66M 150 block for grounding metal conduit |
to bridge two sides of a parallel-connected 66M1SO block
|
|
What is the maximum number of jacks that can be installed on a single-gang faceplate? |
2
4 6 8 |
6
|
|
When do you use singlemode fiber? |
local distance
long distance low bandwidth when low cost is a priority |
long distance
|
|
If you are installing a step-down transformer in a low voltage remote control system, which connections are required to be inside an enclosure? |
All class 1 and 2 connections
The secondary transformer connections Only the high voltage (power wiring) connections Both the primary and secondary connections |
Only the high voltage (power wiring) connections
|
|
What does CATV stand for? |
Community Antenna Television
Community Access Television Common Attenuation Television Common Access Television Vendor |
Community Antenna Television
|
|
For the stepdown transformer shown, what is the voltage induced in the secondary? 10 turns 10 v | 5 turns ?v |
3V
4V 5V 6V |
5V
|
|
How do you test a short? |
voltmeter
ohmmeter wattmeter an1n1eter |
ohmmeter
|
|
How many quarter bends are allowed in a single run of conduit? |
2
4 6 8 |
4
|
|
You are working at a jobsite and discover that the material you are working on contains more than .10% asbestos. What should you do? |
Use a dust mask
Spray water on the area before continuing work. Report the condition to the Chief of DOSH. Report the fact to the building owner within 7 days. |
Report the condition to the Chief of DOSH.
|
|
How far into a building can a flooded cable be run before it must be terminated? |
5 feet
10 feet 20 feet 50 feet |
50 feet
|
|
What type of low-voltage cable is required for use in a ceiling used for air handling? |
fiber-optic
shielded PVC-jacketed plenum-rated cable |
plenum-rated cable
|
|
What might you use to cut flexible metal conduit or liquid tight flex? |
a hacksaw
a pipe cutter a hickey a keyhole saw |
Hacksaw
|
|
Saber saws are designed to cut on the: |
upstroke
downstroke upstroke and downstroke sidestroke |
Upstroke
|
|
On Cat 5 cables, what color is the inside pair of wires (pins 4 & 5)? |
orange
green brown blue |
Blue
|
|
What co lor are 568SC connectors and adapters for multimode fiber? |
red
green beige blue |
Beige
<> Single Mode = Blue |
|
Hacksaws are designed to cut on the: |
upstroke
downstroke upstroke and downstroke sidestroke |
Downstroke
|
|
In which of the following tasks does a hacksaw perform least well? |
cutting flexible conduit
cutting armored cable (BX) cutting liquid tight cutting rigid metal conduit |
cutting rigid metal conduit
|
|
What is the minimum height of a guardrail? |
24"
36" 42" 48" |
42"
|
|
What does " LAN" stand for? |
Local Access Network
Long Access Network Local Area Network Laser Array Node |
Local Area Network
|
|
What material should you never drill with a standard high speed steel drill bit? |
sheet metal
masonry vinyl tile wood |
Masonry
|
|
Which connector is most commonly used for data processing? |
RJ 11
RJ 25 RJ 14 RJ 45 |
RJ 45
|
|
Why Is a conduit bender the best tool to use to bend EMT? |
it produces a perfect bend
it's easier to pull than a hickey it keeps the interior volume of the pipe unchanged it's more portable |
it keeps the interior volume of the pipe unchanged
|
|
Which is the most common type of cable for data? |
CAT 1
CAT 4 CAT 5 CAT 6 |
CAT 5
|
|
A Low-Voltage Systems Contractor can install equipment carrying a maximum of: |
91 volts
110 volts 300 volts 600 volts |
91 volts
|
|
What does ACV stand for? |
accurate voltage
acute concussion victin1 alterative conductor voltage alternating current voltage |
alternating current voltage
|
|
Which of the following tools, once worn, is commonly discarded rather than sharpened? |
standard screwdriver
Phillips-head screwdriver drill bit chisel |
Phillips-head screwdriver
|
|
What is the most common size of fiber optic cable? |
50/125
62.5/125 85/125 100/140 |
62.5/125
|
|
You insert telephone line tester into a wall jack so the number 2 is toward the stepped side of the jack. The red light goes on. This tells you: |
the jack is wired correctly
the polarity is reversed in line 1 the polarity is normal in line 2 there is AC power on the line |
the polarity is reversed in line 1
|
|
What would you generally use to cut EMT? |
a hacksaw
a pipe cutter a hickey either A orB |
either A orB
|
|
How long can a single run of CAT 5 cable in an office building be? |
10 meters
20 meters 50 meters 90 meters |
90 meters (295.276Ft)
|
|
How far must the side rails of ladders extend above a landing? |
24"
36" 48" they must be level with the landing |
36”
|
|
What does the 12 in "MS12" inside a diamond symbol mean? |
12 volt system
12 volt amps capacity 12 positions 12 motors |
12 positions
|
|
How do you tell the difference between 568A cables and 5688 cables? |
568A cables only have 4 wires
5688 cables are shielded The pairs of wires are arranged differently 5688 can only be used for voice transmissions |
The pairs of wires are arranged differently
|
|
The correct way to install wire-nuts is: |
strip ends, insert wires side-by-side and straight, then twist the wire-nut
tight strip a little less than the length of wire-nut, twist wires together with pliers, then spin on the wire-nut strip ends the length of the wire-nut, twist tightly clockwise, use cutters to trim ends even, then twist on the wire-nut hand tight same as c, but then use pliers to add a final crimp. |
strip ends the length of the wire-nut, twist tightly clockwise, use cutters
to trim ends even, then twist on the wire-nut hand tight |
|
What is the name of the outer covering for fiber optic cables? |
F.O.
L.I.U. Armor jacket |
Jacket
|
|
What does a diamond symbol containing "MM" over "R" or "B" mean? |
motor master- red for on, black for off
motor master- red for off, black for on main motor lugs- red for hot and black for neutral main monitor- "R" & "B" are arbitrary identifiers |
motor master- red for on, black for off
|
|
What tool is used to terminate a 25-pair Amphenol plug? |
crimp tool
punch tool butterfly tool needle nose pliers |
butterfly tool
|
|
The safe ty disconnect switch for a motor must be locate d |
within 25 feet of the control station
within 50 feet of the motor and driven equipment within 75 feet and in sight from motor and equipment within 25 feet and in the same room as the motor |
within 50 feet of the motor and driven equipment
|
|
A generator produces electricity by: |
electromotive force.
electro-potential force. centripetal induction. electromagnetic induction. |
electromagnetic induction.
|