Plans and specifications require critical review by the:

- owner to check all the subcontractors


- owner to check all the material suppliers


- contractor and owner to establish all the payment schedules


- contractor and owner to establish an agree ment on the work descriptions

How much start up capital is needed to start a new contracting business?

$ 1,000.


$2,500.


$5,000.


$12,000.

$2,500.

To whom should a Misc-1099 be sent?

- to all corporations receiving mor e t han $600 during a cale ndar year


- to all employees, regardless of how m uch t hey earnto all employees earning over $600 during a calendar yearto a subcont ractor earning over $600 during a cale ndar year

What is the correct way to use a roto- or hammer -drill?
slow speed with light pressure
fast speed with light pressure
slow speed with fim1 pressure
fast speed with as much pressure as you can manage
slow speed with firm pressure

What minimum thickness of plywood is recommended for phone room
backboards?
3/8"
1/2"
3/4"
7 /8"
3/4"

What is the minimum bending radius for fiber optic cables?
2 times the cable diameter
10 times the cable diameter
20 times the cable diameter
40 times the cable diameter
20 times the cable diameter

What DC voltage should you set a megger to when testing the insulation of a wire?
the same as the circuit voltage
slightly less than the normal peak AC
the same as voltage rating of the insulation
a slightly higher DC voltage than the AC peak voltage.
a slightly higher DC voltage than the AC peak voltage.

When measuring conduit for two 90° bends, you should:
add the back-to-back overshoot to the desired length
subtract the back-to-back overshoot to the desired length
divide the desired length by the back-to-back overshoot
divide the back-to-back overshoot by the desired length
add the back-to-back overshoot to the desired length

Which of the following standards covers fire alarms?
NEC770
NEC650
TlA/ElA-607
NFPA 72
NFPA 72

What is the most practical alternative for running conductors between floors of an existing building?
conduit
sleeve
protective insulating material around conductors
run along the outside
conduit

When designing and drawing a low voltage system:
draw on the existing electrical plan
draw on new plans
present as a list, rather than diagram
use a different color
draw on new plans

Two technicians are installing a data cable on one end.

You connect the tracer at the office and the other at the block, but you do not get a signal. What should you conclude?
there is a short in the cable
you connected the cable wrong
you used the wrong cable
cable is cut
you used the wrong cable

Of the following, which is the strongest part of your body?
lower back
lower side
mid chest
upper back, near the shoulders
upper back, near the shoulders

Please refer to the drawing of a spade bit below. Which of the following angles, if ithere, should be maintained when sharpening the bit to get maximum usage
Maintain both
Maintain one
Maintain Both

For a chime/bell system in a residence, it is standard practice to install:
one pushbutton for the whole system
one pushbutton at each door
two push buttons for the whole system
three pushbuttons for the whole system
one pushbutton at each door

What are the general wiring requirements for a 70-volt background-music sound system?
one pair of No. 14 AWG wires
one pair of No. 16 AWG wires
one pair of No. 18 AWG wires
one pair of No. 22 AWG wires
one pair of No. 22 AWG wires

How long can a single run of multimode fiber typically be?
100 Ill
200m
500m
2km
500m

Which would you use to clear or check conduit before pulling wire through
mandrel
auger
fish tape
Roto-Rooter
mandrel

What type of switch is normally used to control a remote control relay?
Multi-pole pushbutton
Two-position rocker
Double pole, single throw, momentary (DPST)
Single pole, double throw (SPOT)
Single pole, double throw (SPOT)

What is the proper way to store tools at a job site?
tools should not be left at the job site
any cover to keep tools from getting wet is adequate
power tools left at the job site must be double-locked
power-actuated tools must be kept in a locked container whenever
unattended
power-actuated tools must be kept in a locked container whenever
unattended

What section of the NEC covers communication circuits?
650
770
800
900
800

What does an octagon with a number in it signify on an electrical plan diagram?
clock system component, with number indicating the component type
plan diagram cross-reference
connection to another point on diagram
low voltage switch with pilot light
clock system component, with number indicating the component type

What is the typical maximum pulling tension for indoor fiber optic cables?
2Sibs
50lbs
100lbs
600lbs
100 Lbs

For low-voltage wiring, use rigid metal conduit to go through ______ for fire protection.
wood joists
drywall
concrete walls
plaster walls
concrete walls

In what range of voltages does a Megger operate?
0-250
200-600
500- 1000
500-5000
500- 5000

Where does the blue wire go in the low-voltage system?
to a switch
to a relay
to a switch and a relay
to the 120-V supply
to a relay

According to NFPA standards, when installing a fire-alarm panel and other
devices attached to the panel:
all components must be purchased at the same time
all devices being attached must be UL-approved for the panel
all devices must be approved by the authority having jurisdiction or listed
for use with the panel
any suitable device, equivalent to a listed device, may be used
all devices must be approved by the authority having jurisdiction or listed
for use with the panel

What is the maximum length of a run of single mode fiber?
200 m
500 m
20 km
80 km
80km

How do you first test fiber?
OTOR
HeNe or LEO laser (visible light)
mode stripper
mandrel
HeNe or LED laser (visible light)

What tool would you use to check that a pipe is adequately grounded?
Megger
Wiggy
Ammeter
Ouija board
Megger

You must use conduit when running wiring through:
cement
drywall
wood timbers
plaster
Cement

What tool would you use to notch wooden studs, floor joists, etc., for the passage of conduit?
drill
hacksaw
wood chisel
keyhole saw
wood chisel
NOTCH

What type of light pulses travel in singlemode fiber optic cables?
low order only
high order only
both high and low order
digital light
low order only

When using a keyhole saw, you should use:
very light pressure
medium pressure
heavy pressure
reverse pressure
very light pressure

You insert telephone line tester into a wall jack so the number 2 is opposite the stepped side of the j ack. The yellow light goes on. This tells you…
the jack is wired correctly
the polarity is reversed in line 1
the polarity is normal in line 2
there is AC power on the line
there is AC power on the line

A device has a resistance of 12 ohms and draws 3 amps. According to Ohm's Law, what voltage should be supplied?
3V
6V
36 v
120 v
36V

Conductor length and conductor size are both proportionally related to:
resistance
impedance
capacitance
attenuation
Resistance

What is the current in this circuit?
2.1 amps
4.0 amps
7.0 amps
12.0 amps
12.0 amps


What does
DCV
stand
for

downward connected var iable
directly connected valve
direct cable voltage
direct current v oltage

direct current voltage


What material would you drill with a standard high speed steel drill bit?
sheet metal
masonry
tile
wood
sheet metal (Steel Bit)
<>
masonry (Carbine)
tile (Diamond)
wood (spade)

If a phone system is ringing on the main line, what is the color of the ring wire?
green
yellow
red
black
Red (1st RING)
Green (1st TIP)
<>
Yellow (2ndRING)
Black (2ndTIP)
White (3rd Ring)
Blue (3rd TIP)

Bending conduit is best done with a:
field hickey
field hockey
field hooey
finial
field hickey

According to NFPA 71, a central station must have at least ______________ person(s) to
assure immediate attention to fire-alarm signals received.
1
2
3
The number doesn't matter.
2

In an local antenna system, everything after channel 14 and up is called:
VHF
UHF
mid high
super high
UHF (Ultra High Frequency)
<>
VHF (Very High Frequency)

How do you measure the length of fiber on a spool?
OTOR
ruler
mechanical reel
count the tun1s around the spool
OTDR (optical time-domain reflectometer)

So und system cables are allowed to fill a raceway to _ _______of its capacity?
100%
90%
750/o
60%
75%

Please refer to the diagrams of three different screwdrivers shown below. Which of the following, if any, is an "electrician's tip" or "cabinet tip" screwdriver?
figure A
figure B
figure C
none of the above
figure C

According to NFPA standard s, if any work is begun on the alarm panel of a central station, you must:
first test the contact closures
notify the alarm company in advance
test all devices on the circuits
restore the panel to normal operation as soon as possible.
restore the panel to normal operation as soon as possible.

How many wires does a typical 66-block hold?
25
so
66
100
100

What color are 568SC connectors and adapters for singlemode fiber?
red
green
beige
blue
Blue

Which bit is best for drilling deep holes?
single-twist bit
double-twist bit
masonry
none of the above
single-twist bit

How should you install vertical cables in a multistory building?
start at the top and pull down, then tie from the bottom up
start at the top and pull down, then tie from the top down
start at the bottom and pull up, then from the tie bottom up
start at the bottom and pull up, then tie from the top down
start at the top and pull down, then tie from the top down

What seismic zone(s) are in California?
1
2
3
3&4
3 & 4

What is the maximum pulling tension for CAT 5 cables?
25
50
100
600lbs
100?

What type of light pulses travel in multi mode fiber optic cables?
low order only
high order only
both high and low order
digital light
both high and low order
<>
Low Order Only (SINGLE MODE)

If you have a 120-V, 20-A circuit on which three 150-W incandescent bulbs, one
250-W television, and one 45-W VCR are installed, can you add a 1200-W heater
without overloading the circuit?
No.
Yes. The current will be 6.4 amps.
Yes. The current will be 16.2 amps.
Yes. The current will be 18.9 amps.
Yes. The current will be 16.2 amps.

Bridge clips are used:
to bridge and ground a punch panel
to bridge and ground a 110-block
to bridge two sides of a parallel-connected 66M 150 block
for grounding metal conduit
to bridge two sides of a parallel-connected 66M1SO block

What is the maximum number of jacks that can be installed on a single-gang faceplate?
2
4
6
8
6

When do you use singlemode fiber?
local distance
long distance
low bandwidth
when low cost is a priority
long distance

If you are installing a step-down transformer in a low voltage remote control system, which connections are required to be inside an enclosure?
All class 1 and 2 connections
The secondary transformer connections
Only the high voltage (power wiring) connections
Both the primary and secondary connections
Only the high voltage (power wiring) connections

What does CATV stand for?
Community Antenna Television
Community Access Television
Common Attenuation Television
Common Access Television Vendor
Community Antenna Television

For the stepdown transformer shown, what is the voltage induced in the
secondary? 10 turns 10 v | 5 turns ?v
3V
4V
5V
6V
5V

How do you test a short?
voltmeter
ohmmeter
wattmeter
an1n1eter
ohmmeter

How many quarter bends are allowed in a single run of conduit?
2
4
6
8
4

You are working at a jobsite and discover that the material you are working on contains more than .10% asbestos. What should you do?
Use a dust mask
Spray water on the area before continuing work.
Report the condition to the Chief of DOSH.
Report the fact to the building owner within 7 days.
Report the condition to the Chief of DOSH.

How far into a building can a flooded cable be run before it must be terminated?
5 feet
10 feet
20 feet
50 feet
50 feet

What type of low-voltage cable is required for use in a ceiling used for air handling?
fiber-optic
shielded
PVC-jacketed
plenum-rated cable
plenum-rated cable

What might you use to cut flexible metal conduit or liquid tight flex?
a hacksaw
a pipe cutter
a hickey
a keyhole saw
Hacksaw

Saber saws are designed to cut on the:
upstroke
downstroke
upstroke and downstroke
sidestroke
Upstroke

On Cat 5 cables, what color is the inside pair of wires (pins 4 & 5)?
orange
green
brown
blue
Blue

What co lor are 568SC connectors and adapters for multimode fiber?
red
green
beige
blue
Beige
<>
Single Mode = Blue

Hacksaws are designed to cut on the:
upstroke
downstroke
upstroke and downstroke
sidestroke
Downstroke

In which of the following tasks does a hacksaw perform least well?
cutting flexible conduit
cutting armored cable (BX)
cutting liquid tight
cutting rigid metal conduit
cutting rigid metal conduit

What is the minimum height of a guardrail?
24"
36"
42"
48"
42"

What does " LAN" stand for?
Local Access Network
Long Access Network
Local Area Network
Laser Array Node
Local Area Network

What material should you never drill with a standard high speed steel drill bit?
sheet metal
masonry
vinyl tile
wood
Masonry

Which connector is most commonly used for data processing?
RJ 11
RJ 25
RJ 14
RJ 45
RJ 45

Why Is a conduit bender the best tool to use to bend EMT?
it produces a perfect bend
it's easier to pull than a hickey
it keeps the interior volume of the pipe unchanged
it's more portable
it keeps the interior volume of the pipe unchanged

Which is the most common type of cable for data?
CAT 1
CAT 4
CAT 5
CAT 6
CAT 5

A Low-Voltage Systems Contractor can install equipment carrying a maximum
of:
91 volts
110 volts
300 volts
600 volts
91 volts

What does ACV stand for?
accurate voltage
acute concussion victin1
alterative conductor voltage
alternating current voltage
alternating current voltage

Which of the following tools, once worn, is commonly discarded rather than sharpened?
standard screwdriver
Phillips-head screwdriver
drill bit
chisel
Phillips-head screwdriver

What is the most common size of fiber optic cable?
50/125
62.5/125
85/125
100/140
62.5/125

You insert telephone line tester into a wall jack so the number 2 is toward the stepped side of the jack. The red light goes on. This tells you:
the jack is wired correctly
the polarity is reversed in line 1
the polarity is normal in line 2
there is AC power on the line
the polarity is reversed in line 1

What would you generally use to cut EMT?
a hacksaw
a pipe cutter
a hickey
either A orB
either A orB

How long can a single run of CAT 5 cable in an office building be?
10 meters
20 meters
50 meters
90 meters
90 meters (295.276Ft)

How far must the side rails of ladders extend above a landing?
24"
36"
48"
they must be level with the landing
36”

What does the 12 in "MS12" inside a diamond symbol mean?
12 volt system
12 volt amps capacity
12 positions
12 motors
12 positions

How do you tell the difference between 568A cables and 5688 cables?
568A cables only have 4 wires
5688 cables are shielded
The pairs of wires are arranged differently
5688 can only be used for voice transmissions
The pairs of wires are arranged differently

The correct way to install wire-nuts is:
strip ends, insert wires side-by-side and straight, then twist the wire-nut
tight
strip a little less than the length of wire-nut, twist wires together with
pliers, then spin on the wire-nut
strip ends the length of the wire-nut, twist tightly clockwise, use cutters
to trim ends even, then twist on the wire-nut hand tight
same as c, but then use pliers to add a final crimp.
strip ends the length of the wire-nut, twist tightly clockwise, use cutters
to trim ends even, then twist on the wire-nut hand tight

What is the name of the outer covering for fiber optic cables?
F.O.
L.I.U.
Armor
jacket
Jacket

What does a diamond symbol containing "MM" over "R" or "B" mean?
motor master- red for on, black for off
motor master- red for off, black for on
main motor lugs- red for hot and black for neutral
main monitor- "R" & "B" are arbitrary identifiers
motor master- red for on, black for off

What tool is used to terminate a 25-pair Amphenol plug?
crimp tool
punch tool
butterfly tool
needle nose pliers
butterfly tool

The safe ty disconnect switch for a motor must be locate d
within 25 feet of the control station
within 50 feet of the motor and driven equipment
within 75 feet and in sight from motor and equipment
within 25 feet and in the same room as the motor
within 50 feet of the motor and driven equipment

A generator produces electricity by:
electromotive force.
electro-potential force.
centripetal induction.
electromagnetic induction.
electromagnetic induction.