• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/19

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

19 Cards in this Set

  • Front
  • Back
Commandant policy mandates that fuel tanks be tested for free water :
-
-
-
Prior to receiving fuel (If the receiving tank had been water ballasted)
24 hours after receiving fuel
On a monthly basis
The basic types of lube oil contamination are:
-
-
-
-
Fuel Dilution
Acid Contamination
Water (Condensation or Instrusion)
Insolubles
Vessels that do not have a system dedicated to collect used synthetic oils shall use _ or __ gallon Steel containers properly labeled per the Hazardous Waste Management Manual COMDTINST ________ for eventual shore recycling
5
55
M16478.1
Detector kit tests includes the use of:
-
-
-
AEL MKI(fwd)- Viewer Kit, Free Water Detector
AEL MKIII(cfd)- Contaminated Fuel Detector kit
FSII- A B2 Anti-Icing Additive Test Kit
While there may be differences in the components of a lube oil or fuel oil purifier, often the only difference is the presence of a ______ on the lube oil purifiers.
Heater
No JP-5 fuel filter may be bypassed during helicopter refueling operations without the concurrence of the:
-
-
-
Commanding Officer
Engineer Officer
Pilot-In-Command(PIC)
Gasoline is classified as category _.
I Flammable
Gasoline and JP-5 fuel systems are what NSTM chapter?
542
Ship fuel and fuel systems are what NSTM chapter?
541
Stowage, handling, and disposal of hazardous general use consumables NSTM chapter ___.
670
All fuel nozzles used to dispense fuel to helicopters shall be of the self closing type, non sparking construction, and have an installed ___ ____ screen.
100
Mesh
______ ________ shall be changed every three years, or when one million gallons of fuel have been dispensed, or when differential pressure of the filter separator is 15 PSI.
Filter Elements
Stowage, handling, and disposal of hazardous general use consumables NSTM chapter ___.
670
A ________ is installed at the fueling nozzle, used as a final barrier aginst particulate contamination.
Strainer
The actual purification takes place within the ____ _________ of the purifier.
Bowl Assembly
Purifiers are essentially motar-driven centrifuges they separate contaminated fuel into its three major components:
-
-
-
Water(Heavy Phase)
Purified Fuel(Light Phase)
Solids and/or Sludge
The two types of authorized fuel addditives currently approved are:
-
-
Biobor JF(A liquid fuel additive that combats fungus and other microbial life in hydrocarbon fuels)

Nalfleet 9-303(Acts to disperse sediments and bacterial slimes and prevents plugging in filters and fuel lines)
Only under an extreme operational emergency shall a fuel be loaded onboard for shipboard use if it's flash point is below __ ºC or ___°F
52
125
Fuel tanks are considered ____ according to gas free egineering NSTM chapter ___.
IDLH(Immediately Dangerous to Life or Health)
074 Volume 3