The water in a boiler is heated, turns to steam, and leaves the boiler through the ______________ .
main steam line
When steam releases heat in the heat exchanger, it turns to ______________ .
condensate
What type of pump returns condensate from the system back to the boiler?
vacuum
What valve allows the flow of water in one direction?
The check valve
The feedwater _________ valve should be located as close to the shell of the boiler as practical.
stop
A ________ after each heating unit allows condensate to pass through to the return line.
steam trap
What may be required on some boilers to remove oxygen and other gases?
feedwater heater
The feedwater _____ valve opens and closes automatically.
check
The vacuum pump pumps water and discharges air to the __________ .
atmosphere
The range of pressure on the vacuum switch is usually ___________ .
2" to 8"
The primary function of a low water fuel cutoff is to _________ .
shut down the burner if the water level drops below the safe operating level
Water added to the boiler to replace water lost due to leaks and blowing down is know as _____ water.
makeup
Excessive use of cold city makeup water reduces overall boiler efficiency because the water must be ______ before use in the boiler.
heated
An auxiliary low fuel cutoff is installed ________ .
slightly below the primary low water fuel cutoff
The _____ shuts off the burner in the event of low water.
low water fuel cutoff
Water is supplied to the condensate return tank by the ______ pump.
vacuum
The feedwater regulator is located at the ______.
NOWL
The ________ maintains a constant water level in the boiler.
feedwater regulator
The low water fuel cutoff should be tested ________ .
daily
The burner should be _____ when the low water fuel cutoff is blown down.
firing
A high water level condition in the boiler could lead to water hammer.
True
A low water level condition in the boiler can result in damage to boiler heating surfaces.
True
The check valve on the feedwater line should be located closest to the shell of the boiler.
False
The check valve allows the flow of water in one direction only.
True
The check valve on the feedwater line commonly has a valve disc that swings to open and close the valve.
True
A condensate return tank collects condensate returned from heating units for use in the boiler.
True
A globe valve used as a feedwater stop valve must be installed so inlet pressure is applied from under the valve disc.
True
The stop valve on the feedwater line should be located closest to the boiler.
True
The vacuum pump is designed to discharge air and pump water.
True
Centrifugal feedwater pumps are commonly driven by steam.
False
A check valve is opened by turning the handle counterclockwise.
False
A low water fuel cutoff is located slightly below the NOWL.
True
The range of pressure on the vacuum switch on a vacuum pump is usually 2″ to 8″.
True
An evaporation test is performed by opening the low water fuel cutoff blowdown valve by hand.
False
Any loss of water in the system must be made up by the makeup water feeder.
True
The boiler operator must be present during an evaporation test.
True
The makeup water feeder can be used as feedwater.
False
Most makeup water contains some scale-forming salts.
True
The function of the automatic makeup water feeder is to replace water that has been lost.
True
The automatic city water makeup water feeder is located slightly below the NOWL.
True