What is the min. Clearance to combustible materials above a counter appliance? |
36” |
|
What is the minimum distance between a pool heater and property line? |
18” |
|
What is the min. Unprotected distance between a garage unit heater to the floor? |
8 feet |
|
Which room is not suitable for the installation of a gas range A- a bedroom B- rumpus room C- a bed sitting room D- a dining room |
A- a bedroom |
|
What is the min. Unprotected clearance to combustible materials above a hot plate |
30” |
|
What category of appliance With a draft hood be? |
Category 1 |
|
Which type of vent would typically be used on a category 1 appliance |
B vent |
|
What is the min. Required service clearance for gas fired equipment? |
24” |
|
Which furnace may be serviced, but not installed |
Floor furnace |
|
When a heat exchanger in a house furnace is cracked, what corrective action is required? |
Replace the heat exchanger |