• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/47

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

47 Cards in this Set

  • Front
  • Back

Which of the following would use the Set directive?




A. Put a blue dot on the appointment slot on the outpatient schedule.


B. Make the order go to Beaker


C. Change the priority of the order from Routine to STAT


D. Transmit to a radiology interface

C. Change the priority of the order from Routine to STAT

Which of the following would use the Send directive?




A. Put a blue dot on the appointment slot on the outpatient schedule.


B. Make the order go to Beaker


C. Change the priority of the order from Routine to STAT


D. Transmit to a radiology interface

B. Make the order go to Beaker




D. Transmit to a radiology interface

True/False: For the Send, Do, and Set directives, the final step order transmittal does is to consult the Destination Map master file.

False

True/False: "Order type" and "Priority" are properties that order transmittal can be told to evaluate in a condition statement.

True

Which of the following destination descriptors should map to BEAKER ORDER ENQUEUE?




A. pat_interface


B. error_pool


C. pat_beaker_accession


D. pat_beaker

D. pat_beaker

Which of the following auto-accessioning actions are dependent on order transmittal?




A. The order gets sent to Beaker


B. A specimen ID is generated


C. A label is printed from Beaker


D. The order record is inactivated

A. The order gets sent to Beaker




B. A specimen ID is generated

True/False: Using order transmittal to set the priority of an order to Add-on sends an In Basket message to the Add-ons folder of the lab techs.

False

Where should all Beaker-related descriptors be "translated"?




A. In each destination map


B. Only in the Facility destination map


C. In the Lab record


D. In the Department Record

B. Only in the Facility destination map

When a label printing event occurs in Beaker, which of the following records might Beaker check for printing setup?




A. Test (OVT)


B. Lab (LDF)


C. Department (DEP)


D. Beaker Facility (LDF 1)

A. Test (OVT)




B. Lab (LDF)




D. Beaker Facility (LDF 1)

True/False: The print event setup in the facility record specifies the exact printer to be used for specific types of labels.

False

A test will be resulted in the EMH Reference Lab, but the specimen is collected in the EMH Hospital Lab. Which record will be used to determine what labels should print?




A. EMH Reference Lab, laboratory record


B. EMH Reference Lab, department record


C. EMH Hospital Lab, laboratory record


D. EMH Hospital Lab, department record

A. EMH Reference Lab, laboratory record

What are the associations that a follow-ups can have?




A. Requisition


B. Case


C. Specimen


D. QC Specimen


E. Unassociated



A. Requisition


B. Case


C. Specimen


D. QC Specimen


E. Unassociated

What steps need to be included to create a new follow-up?




A. Add a value to category list RES 51300


B. Add a value to category list RES 51165


C. Specify what the follow-up type is associated with in the category list


D. Specify what the follow-up type is associate with in the Facility record


E. Define the follow-up type int he Facility record


F. Define the follow-up type in the Lab record

B. Add a value to category list RES 51165




C. Specify what the follow-up type is associated with in the category list




E. Define the follow-up type int he Facility record

True/False: In the Follow-Up Definitions form the Facility record, you can change the association type of the follow-up.

False

Which server is able to communicate directly with the instruments in each instrument's own manner and communicate with Epic using HL7 interface messages?




A. Bridges


B. Interface engine


C. Middle tier


D. Beaker

C. Middle tier

This type of record is used for storing values that return to Epic from an incoming results message.




A. Result (OVR)


B. Order (ORD)


C. Test (OVT)


D. Result Component (LRR)

A. Result (OVR)

In which segment of an HL7 instrument interface message will the name of the test appear?




A. MSH


B. OBX


C. PV1


D. OBR

D. OBR

Which of the following actions can automatically trigger an interface?




A. Receive a specimen


B. Aliquot a specimen


C. Repeat a component


D. Add on a test

A. Receive a specimen




B. Aliquot a specimen




C. Repeat a component




D. Add on a test

Which of the following are options for the EMR Participant field in a submitter record?




A. Participating


B. Participating without patient creation


C. Non-participating


D. Temporarily participating

A. Participating




B. Participating without patient creation




C. Non-participating

For billing, only choose __________ when the EMR participant is __________.




A. Client Bill; Non-participating


B. Client Bill; Participating


C. Patient Bill; Non-participating


D. Patient Bill; Participating

D. Patient Bill; Participating

Values for certain fields in a submitter record can cause additional fields to appear in Requisition Entry. Identify those fields.




A. EMR Participant


B. Type of submitter


C. Requisition Item (required/recommended item)


D. Custom Field Item

B. Type of submitter




D. Custom Field Item

True/False: When indicating that an item will be required, it is not necessary to also specify a default value.

True

True/False: Only tests associated with a result report section are printed on result reports.

False

You get a call from an inpatient provider informing you that all of the result reports she receives have a separate header for each test on the report. She would like the tests to be displayed in a more tabular view. Which record will you need to edit to make this change?




A. Result Report Format


B. Result Report Template


B. Result Report Routing


C. Result Report Section

A. Result Report Format

How many result report sections can one test be associated with?




A. One


B. As many lab lab sections can result the test


C. On per lab in a facility


D. Unlimited

A. One

Where do you specify which result reporting template (SmartText) should be used?




A. Result report format record


B. Result report routing record


C. Facility record


D. Submitter record

A. Result report format record

The Emergency Department at your organization requires that their result reports get sent out more frequently than other departments at your organization. What type of record will you need to create to meet this request?






A. Result Report Format


B. Result Report Template


C. Result Report Routing


D. Result Report Secdtion

C. Result Report Routing

Which of the following are records in which you can set up a hold?




A. Facility


B. Laboratory


C. Test


D. Method

A. Facility




B. Laboratory




C. Test

Which of the following are severities of holds that can be placed?




A. FYI


B. Hard Hold


C. Pause


D. Warning

A. FYI




B. Hard Hold




D. Warning

In which of the following records/forms do you determine that a hold is a hard hold or warning?




A. Facility (Charges/Holds Setup form)


B. Facility (Holds Definitions form)


C. Category List


D. Laboratory (Charges/Holds Setup form)

B. Facility (Holds Definitions form)

True/False: A Result Component (LRR) record is generates when a specimen is received into the lab.

False (OVR record is created)

A specimen (OVS) record is an example of a _______ record that is created when the __________.




A. Dynamic; specimen is accessioned


B. Dynamic; order is released


C. Static; specimen is accessioned


D. Static; order is released

A. Dynamic; specimen is accessioned

A lab tech enters a requisition for a test. He places an order, generates a specimen, documents collection information, but doesn't receive it into the lab. What dynamic records are created?




A. Order (ORD)


B. Test (OVT)


C. Result (OVR)


D. Specimen (OVS)



A. Order (ORD)




D. Specimen (OVS)

True/False: Networked items always point to information is the same master file.

False

In order transmittal, which directive causes tasks to appear on a work list?




A. Do


B. Set


C. Sent


D. Create

D. Create

True/False: Beaker orders collected by nurses may pass through order transmittal multiple times.

True

Which directive ensures that lab orders get to Beaker?




A. Do


B. Set


C. Send


D. Create

C. Send

True/False: For Send directives, the destination descriptor specifies the exact workstation where a report will be sent.

False

True/False: Beaker-specific label printing is set up through order transmittal rules.

False

Which record(s) might the system consult when a label printing event of accessioning occurs in Beaker?




A. Test record


B. Lab record (performing lab)


C. Lab record (collecting lab)


D. Facility

A. Test record




B. Lab record (performing lab)




D. Facility

True/False: You are manually print a label. In the Printer field, you select LAB LABEL PRINTER. LAB LABEL PRINTER is an example of a device record.

True

Contains a line of data for an item (if there are multiple lines).

Line Number

Record-viewing tool where you can choose the items that are displayed.

EA VIEWID

Used to keep track of changes in records over time.

Contacts

Records in this type of database are created during workflows.

Dynamic

Record-viewing tool where related data is displayed in table format.

Record Viewer

Records in this type of database are unaffected by end user workflows.

Static