MDE ALARMS

CRANKCASE PRESSURE HIGH: 4” H2O.


L/O PRE-SHUTDOWN: >650 17+/-2, >650 46+/-2.


J/W TEMP HIGH: 208+/-9


OVSP TRIP: 1020 RPM


L/O TEMP HIGH: 214


L/O PRESSURE SHT DWN: 17+/-2 <650 RPM, 36+/-2 >650 RPM

RED GEAR ALARMS

THRUST BRG TEMP HIGH: 155


L/O TEMP HIGH: 133


L/O PRESSURE LOW: 13

SSDG ALARMS

J/W TEMP HIGH: 214


OVSP TRIP: 1330


L/O PRESSURE SHT DWN: 26 psi


L/O PRESSURE PRE-SHT DWN: 39.2 psi

EDG ALARMS

J/W TEMP HIGH: 225


OVSP TRIP: 2070 RPM


L/O PRESSURE SHT DWN: 10 psi


L/O PRESSURE PRE-SHUTDOWN: 23 psi

EDG ALARMS

J/W TEMP HIGH: 225


OVSP TRIP: 2070 RPM


L/O PRESSURE SHT DWN: 10 psi


L/O PRESSURE PRE-SHUTDOWN: 23 psi

5 PERMISSIVES

1. BARRING DEVICE DISENGAGED


TURNING GEAR DISENGAGED


SUFFICIENT R/G L/O PRESSURE


PRE-LUBE PUMP ON


AIR DAMPENERS OPEN

EDG ALARMS

J/W TEMP HIGH: 225


OVSP TRIP: 2070 RPM


L/O PRESSURE SHT DWN: 10 psi


L/O PRESSURE PRE-SHUTDOWN: 23 psi

5 PERMISSIVES

1. BARRING DEVICE DISENGAGED


TURNING GEAR DISENGAGED


SUFFICIENT R/G L/O PRESSURE


PRE-LUBE PUMP ON


AIR DAMPENERS OPEN

SHIP’S SERVICE AIR

125 psi


Control Air (subsystem) 125 psi controls; Leslie valves, f/o pneumatic valves, OWS, FOP, Incinerator


Located behind sewage atmospheric tank.

EDG ALARMS

J/W TEMP HIGH: 225


OVSP TRIP: 2070 RPM


L/O PRESSURE SHT DWN: 10 psi


L/O PRESSURE PRE-SHUTDOWN: 23 psi

5 PERMISSIVES

1. BARRING DEVICE DISENGAGED


TURNING GEAR DISENGAGED


SUFFICIENT R/G L/O PRESSURE


PRE-LUBE PUMP ON


AIR DAMPENERS OPEN

SHIP’S SERVICE AIR

125 psi


Control Air (subsystem) 125 psi controls; Leslie valves, f/o pneumatic valves, OWS, FOP, Incinerator


Located behind sewage atmospheric tank.

Start Air

250 psi


Clutch Air (subsystem) 150 psi dehydrator located stbd aft upper mmr, auto de clutch at 90 psi.


Whistle Air System: 125 psi. Port, aft corner of bridge.


Fuel Tanks

4-17-1


4-17-4


4-30-0


4-30-1


4-30-2


3-48-0


3-48-1


3-48-2


3-54-0


3-61-1


3-62-2


01-78-1

Ballast Tanks

4-0-0 Focsal


4-6-0 Bowthruster


4-21-0 Crane Pedestal


4-30-3 Catwalk


4-30-4 Catwalk


4-48-1 Lower Parts


4-48-2 Lower Parts


4-57-0 Lower Parts

Reasons for RMD

Special Sea


Restricted Waters


Small Boat


Aton


Man OVBD


Fog


OOD Deems Necessary