CG-3378
Boat Alterations
CG-3379
Ship Alterations
CG-2920
Current Ships Maintenance Report
CG-3439
Electronics Alterations
CG04094
Shore Station Maintenance Request
Boat Alt (3378) is used to approve and change electronic equipment on?
Standard vessels under 65 feet in length
Ship Alt (3379) is used to approve and change electronic equipment on?
Vessels 65 feet in length or greater
The Current Ships Maintenance Project form (2920), or CSMP, is used by who and for what?
· By vessels of 65 feet or greater, and
· To request assistance with projects that are beyond the ability of the unit’s workforce.
Electronics Alterations, or Electron Alts (3439), are issued to describe and approve a change to installed electronics equipment on?
· All Coast Guard shore units, and
· Nonstandard boats.
The Shore Station Maintenance Request or SSMR (4094) is the shore
unit’s version of a CSMP. The SSMR is used by who and for what?
· At shore stations, and
· To request maintenance related changes, replacements and improvements to electronic equipment and spaces.
How many types of safety tags are there, and what color are they?
Two
Caution tags (Yellow)
Danger tags (Red)
There must be less than ____ ohms of resistance between the safety ground lead and the neutral lead in the AC power line.
0.5 ohms
Define configuration management.
A system of management which ensure that electronic equipment and procedures are done according to Coast Guard established standards.
Who is responsible for CG wide configuration management?
SMEF
Current field change listings can be found in what pubs (Instructions
magazines)?
a. COMDTINST M4410.5,
b. CGPMS Work Schedule Book
c. System Times (Formerly T-Magazine)
d. Electronic Installation Maintenance Books
Policies and procedures for BoatAlts can be found in COMDINST
Naval Engineering Manual, COMDTINST M13020.1
What type of information is contained in system block drawings?
a. Block labels for each piece of equipment in a system.
b. Major signal flow.
c. Power distribution lines.
What is the color of an Out Of Calibration tag?
orange
Completed Inactive Record Sheets should be kept for__________ months as per (Instruction) __________.
6 months, COMDINST 9077.1B
The minimum size (length and diameter) of any driven electrode (ground rods) to be used in any CG installation is
10 ft, ¾ inch in diameter
In order to insure the accuracy of all tag-out logs, an audit of existing tagged-out equipment should be conducted every ___.
two weeks
The maximum impedance allowed between earth ground and a facilities ground system is
less than 10 ohms
The maximum acceptable resistance between the ground safety (green) lead and the AC neutral lead is
less than .5 ohms