An evaporator coil must he installed at least |
at least 2-3in above the heat exchanger |
|
A direct expansion evaporator coil |
has the controlled medium in contact with the coil |
|
What type of evaporator coils ate commonly used in residential up flow systems with limited plenum space? |
an N flow |
|
Rooftop package unit evaporators coils are commonly installed |
on the negative side of the blower before the heat exchanger |
|
what is the minimum slope for a drain line? |
1/8” per foot |
|
What are the symptoms of a TXV air conditioning system if it has lost its charge? |
Superheat will increase, low side pressure will decrease. |
|
when is a P trap used? |
When the evaporator coils is on the negative side of the blower |
|
When using galvanized steel as an auxiliary drain pan, what is the minimum thickness of the steel? |
26 guage |
|
what is the heating value of a number 2 heating oil? |
140,000 BTU per Gallon |
|
What is the common operating pressure of a high side oil burner? |
100 psig |
|
What is the size of a fill pipe on an oil storage tank? |
2” |
|
What safety feature is used on an inside oil storage tank that will protect against a house fire? |
a fuse-type globe valve |
|
What is the size of an air vent on an oil storage tank? |
1 1/4 inch |
|
What effect, if any, would a decrease of primary air have on combustion? |
It would increase CO2 percentage. |
|
What effect if any, would an increase of primary air have on combustion? |
It would increase efficiency |
|
What is the secondary voltage of the ignition transformer used on a high-pressure oil burner? |
10,000 volts |
|
What is the purpose of an electrode in a high-pressure gas burner? |
its used to carry the spark to the point of ignition |
|
what is the measurement of the spark plug gap on an electrode assembly? |
1/8” |
|
The capacity of a high-pressure oil burner nozzle is rated in |
GPH |
|
What are the three different spray patterns that are used on a nozzle? |
Solid, Semisolid, hollow |
|
The spray angle ranges from |
30-90 degrees |
|
What type of motor is used on a residential high-pressure oil burner? |
split-phase |
|
What is the speed of the burner motor on a high pressure gun burner? |
1,725 or 3,450rpm |
|
What is a common capacity of an indoor oil tank? |
275 gallons |
|
What type of lubricant should be used in the burner motor of a high-pressure gas burner? |
10-weight nondetergent type oil |
|
What are the three products produced in the combustion process? |
H2O, CO2, and N |
|
A common C02 reading for an oil furnace is? |
10-12% |
|
A common C02 reading for a gas fired furnace is? |
8.5-9.5% |
|
What types of symptoms will be present if the sensing bulb of a TXV is not properly connected? |
High suction pressure and low super heat |
|
On a standing pilot furnace, the thermocouple must be replaced when |
the millivolt reading is 22 or lower |
|
If a combination has a new thermocouple and the pilot will not stay lit then… |
The gas valve needs to be replaced |
|
Which way do you turn a gas valve regulator to reduce pressure? |
Counter clockwise |