The spec for installation and maintainence of the ILFE gas fire of max input 5.6kW net is?




i BS5871-1


ii BS5871-2


iii bs5871-3


iv BS 5871 - 4

A. BS5871-2

Where a heating stove is flued into a clay lined, brick chimney by a section of metal, twin wall flue pipe it must pass through the register plate by at least?


i 25mm


ii 100mm


iii 125mm


iv 150mm

A. 150mm

A cassette fire is?


i A flueless appliance


ii An open flue appliance


iii A room sealed appliance


iv Never permitted to be installed to an unlined chimney

A. An open flue appliance

A DFE is?


i A highly efficient heating appliance


ii An inefficient heating appliance


iii A low cost method of providing a realistic "real" fire gas appearance


iv Always rated at less than 7kwnet

A. An inefficient heating appliance

Flueless space heaters will always require?


i A catalytic panel


ii An extraction fan


iii Purpose provided ventilation


iv To be recessed into the wall cavity

A. Purpose provided ventilation

A radiant convector gas fire rated at 6kwnet (Flue category B11) fitted with an ASD could be installed in?


i Bedroom


ii Bathroom


iii Shower room


iv Compartment

A. Bedroom

An ILFE rated at 5.7kwnet (Flue category B11) Would normally require




i No purpose provided ventilation


ii A minimum of 21cm2 purpose ventilation


iii A minimum of 28.5cm2 purpose ventilation


iv A minimum of 100cm2 purpose ventilation

A. No purpose provided ventilation

Where a wall has been removed between dining and living room in which each room has identical DFE fires (max rated input of 10.5kw net each) and a 100cm2 brass floor vent in accordance with manufacturers instructions. What action is required due to the removal of the wall?


i No action required


ii Increase one vent by 35cm2


iii Increase both vents by 35cm2


iv Alternation not permitted unless one DFE is removed

A. Increase one vent by 35cm2

Ventilation for a flueless fire must be?


i Provided at high and low level


ii Be directed to outside


iii At least 1m from the appliance


iv both ii and iii

A. both ii and iii

A conservatory ( which has openable windows) has a volume of 40m3 and contains a fluless space heater rated at 2.35kw net. What minimum size of ventilation is required?


i No ventilation is required


ii 100cm2


iii 155cm2


iv Installation not permitted

A. 2.35kw x 1000 = 2350


2350 watts / 45 w = 52.2222 ( more than minimum = 40cm3)




Installation not permitted



A free standing greenhouse has two flueless heaters each rated at 2.35kw net volum of the green house is 105m3 what ventilation provision is acceptible


i No ventilation


ii 40cm 2 at high level and 40cm2 at low level


iii 80cm 2 at high level and 80cm2 at low level


iv 40cm 2 at high level and 80cm2 at low level

A. 80cm 2 at high level and 80cm2 at low level

The purpose of a hearth plate is?


i To provide information on the correct application of the flue system


ii To provide info on the commissioning requirements of the flue system


iii Record that the fle system has been properly commissioned


iv Advise non competent persons of the need for proper appliance selection



A. To provide information on the correct application of the flue system

The minimum diameter of flue pipe for a radiant convector fire is?


i 100mm


ii 125mm


iii 150mm


iv 175mm

A. 125mm

The minimum diameter of flue pipe for a radiant convector fire is?


i 100mm


ii 125mm


iii 150mm


iv 175mm

A. 175mm

If a gas fire is fitted to a brick chimney, any damper must be?




i Checked to ensure it is clear and fully operational


ii Removed


iii Permanently fixed in the open position


iv Either ii or iii

A. Either ii or iii

Flues constructed of pre cast blocks?


i Can be used for any radiant/convector gas fire


ii Can transfer to an exposed flexible metallic flue liner (provided it is fully contained within the attic / loft space)


iii Must be checked internally by ise of fibre optic camera when any appliance is initially installed


iv must be visually inspected

A. must be visually inspected

A DFE is connected to a clay lined brick chimney and a large opening which measures 1m wide x 1.2 high. if the chimney is 8m high, what is the size diameter of the clay liner




i 225mm


ii 250mm


iii 300mm


iv 350mm

A. 350mm ( Table 18.6.5)

The maximum volume of catchment void behind a radiant / convector fire is?




i 247dm3


ii 475dm3


iii 650 dm3


iv 800dm3

A. 247dm3

Which option defines the correct spec for an outset fire?



110 +/- 10mm minimum throat


50mm minimum obstruction distance

110 minimum throat 50mm minimum obstruction distance

A closure plate attached to a marble surface should be?


i Fixed and sealed on all 4 sides by heat resistant silicone sealant?


ii Fixed and sealed on all 4 sides by intumescent sealant


iii Fixed and sealed on all 4 sides by heat resistant tape


iv Fixed by screws and sealed on all sides by heat resistant tape



A. Fixed and sealed on all 4 sides by heat resistant tape

What temp must sealing tapes / materials used in installation of a gas fire be able to withstand before losing their adhesive properties




i 100°c


ii 200°c


iii 250°c


iv 500°c



A. 100°c

A spigot restrictor is required when?


i With pre- cast flues


ii When there is an excessive flue draught


iii When there is a poor flue draught


iv Only with brick built chimneys

A. When there is an excessive flue draught

No hearth is required below a radiant/convector gas fire provided


i The burner is at least 50mm above any combustible floor covering


ii The burner is at least 225mm above any combustible floor covering


iii The burner is at least 50mm above any uncovered floor


iv The burner is at least 225mm above any uncovered floor.



A. The burner is at least 225mm above any combustible floor covering

A hearth used in conjuntion with an ILFE gas fire:


i Must be a minimum of 12mm thick and constructed from non combustible material


ii must be a minimum of 50mm thick and constructed from non combustible material


iii Must extend at least 300mm either side of the flame or incandescent material


iv Is not required provided a fender of at least 50mm high is provided

A. Must be a minimum of 12mm thick and constructed from non combustible material

To prevent contact with the naked flame of an ILFE or DFE fitted at floor level?


i A dress guard must be fitted to the fire


ii A fire gaurd must be permanently fitted


iii A warning label must be left attached to the fire and only removed by the customer


iv A suitable hearth or fender must be installed

A. A suitable hearth or fender must be installed

A gas fire is connected to a brick chimney with an internal diameter of 225mm which terminates with a chimney pot. The property is rural and there have been problems with jackdraws nesting on neighbouring properties terminals. What action should be taken in this situation.




i No action required


ii The pot should be removed and replaced by a terminal


iii A bird guard fitted to the pot


iv A CO detector to be installed in the room containing the fire



A. A bird guard fitted to the pot

With an new installation of a fire an isolating valve?




i Is required unless it is not reasonably practical to be fitted


ii Is only required for surface connection, not concealed


iii Is only required for concealed connection


iv Can be fitted at the discretion of the installer

A. Is required unless it is not reasonably practical to be fitted

The correct burner pressure of a modern natural gas, radiant convector gas fire is achieved by?




i An appliance regulator


ii Controlling the inlet supply pressure at 20mbar


iii The customer adjusting the gas tap


iv A liquid expansion thermostat

A. Controlling the inlet supply pressure at 20mbar

An ASD will?


i Cause the fire to "fail safe" in the event that the CO levels in the room reach 1.5 to 2%


ii Cause the fire to "fail safe" in the event that the CO2 levels in the room reach 1.5 to 2%


iii Cause the fire to "fail safe" in the event of flame failure


iv Reduce the frequency of any maintainence

A. Cause the fire to "fail safe" in the event that the CO2 levels in the room reach 1.5 to 2%

A test for spillage on any flue type B11 space heater


i Must be performed in strict adherence with the manufacturers guidance


ii Must be performed following the general guidance given in BS5440-1


iii can be performed using a mirror or smoke match


iv Must be performed with the fire turned off after having been in operation for at least 5 minutes immediately prior to the test

A. Must be performed in strict adherence with the manufacturers guidance