• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/65

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

65 Cards in this Set

  • Front
  • Back

With respect to Fuels ordinary combustible materials include

Wood and paper

All portable extinguishers are classified according to their

Intended use

A dry chemical extinguisher rated 60-B is capable of extinguishing a

60 ft2 flammable liquid pan fire

What Advantage does CO2 have over a dry chemical extinguisher

CO2 does not leave a residue or corrode electrical contacts

Extinguishing agent safe for use on fires in or near energized electrical equipment include

Carbon dioxide and dry chemical

How much water is required for a fire extinguisher to receive a 2-A rating

2 1/2 gallons

When approaching a fire, stored- pressure water extinguishers are designed to be discharged with the nozzle aimed at the

Base of the fire

A blue circle with a letter designation in the center would indicate and extinguisher is rated for use on

Class C Fires

Class B fires involve fuels such as

Flammable liquids

A green triangle containing a letter would indicate and extinguisher to be used on a

Class A fire

Energized electrical equipment in the surrounding area have to be protected with extinguishers that has a

Class C rating

Extinguishers suitable for class A fire's can be identified by a what containing the letter A. If colored it should be

Triangle green

A stored pressure water extinguisher should be chosen to attack a

Class A fire

The preferred method of applying dry chemical agents to flammable liquid spill fires is to

Direct the stream at the base of the fire using a sweeping motion

Carbon dioxide extinguishers are generally rated for

Class B and C Fires

An electric motor fire is best extinguished by using CO2 because it

Leaves no residue

Extinguishers suitable for class B fires can be identified by a what containing the letter B

Red Square

Extinguishers suitable for Class C Fires can be identified by a what containing the letter C

Blue circle

A multipurpose dry chemical extinguisher is rated for class

A B and C Fires

The proper type of extinguisher for a fire involving magnesium Titanium or sodium is

Dry powder

A Class D fire involves

Combustible metals

Fire involving flammable liquids and gases where applied foam and dry chemical agents will be needed or

Class B fires

Extinguishers suitable for class D fires can be identified by a what containing the letter D

Yellow star

Fires involving combustible Metals such as magnesium titanium zirconium sodium and potassium are

Class D fires

A carbon dioxide CO2 extinguishers means of discharge is

Stored liquefied Compressed Gas

A pump tank extinguisher rated as 4-A can be expected to extinguish approximately

Twice as much fire as one rated 2-A

A dry chemical fire extinguisher rated as 10-B should be capable of extinguishing

10 times as much fire as a unit rated as 1B

Dry powder extinguishers are rated for use on

Class D fires

What extinguisher may be required to extinguish a restaurant kitchen fire involving fryers

Type K

Class C Fires involve

Energized electrical equipment

One method fire extinguishers extinguish is by

Cooling

Halon fire extinguishers are primarily designed for use on

Class B and C Fires

Which type of portable fire extinguisher is least likely to expose the operator to electrical shock

Dry chemical

AFFF Aqueous film forming foam extinguishers are suitable for use on

Class A and B fires

Prior to squeezing the handle of a dry chemical fire extinguisher the nozzle should be aimed

At the base of the fire

Injury that could occur by placing your hand on the Horn of a CO2 extinguisher before discharge

Shock

It is dangerous to apply a stream of water to energized electrical equipment because

Water can conduct electricity back to the extinguisher

How many basic steps is there to operate a fire extinguisher

4

Class C Fires can be extinguished using

Multi-purpose dry chemicals

What factors should be considered When selecting a fire extinguisher

The fuel

Fire extinguishers should be inspected

Once a year

The greatest concern associated with selecting too small of an extinguisher is that

The operator has to get closer to the fire

Gases that do not conduct electricity or leave a residue and or non-volatile are

Clean agents

What extinguishing agent damages the ozone layer

Halon

What is the relationship between dry powder and dry chemical extinguisher agents

They are entirely different substances with entirely different applications

What does the acronym PASS mean

Pull, Aim, Squeeze, sweep

Pump tank extinguishers are used to apply

Water

Water type extinguishers exposed to weather below 40 degrees require what to be added

Antifreeze

A loaded stream fire extinguisher

Prevent freezing by adding a anti-freezing agent

AFFF portable fire extinguishers use what means for expelling their contents. Aqueous film forming foam

Compressed air

A phenomenon that occurs when mixtures of alkaline base chemicals and certain cooking oils come into contact resulting in the formation of a soapy film is called

Saponification

The term for water soluble flammable liquids such as alcohols acetone and others

Polar solvents

The reason I fire extinguisher class icon would have a slash through it is because

Using the extinguisher on that class of fire would create additional risk

Dry chemical extinguishers can be used on Class C Fires because dry chemicals

Do not conduct electricity

Water Mist fire extinguishers are safe to use on energized electrical equipment because the water than use is

Deionized

Fire extinguishers that are most effective or static pools of flammable liquids

Aqueous film forming foam. AFFF extinguishers

The two basic designs for handheld dry chemical extinguishers

Cartridge and stored pressure

Halogenated agents extinguish a fire by

Interrupting chain reaction

When it comes to fire extinguishers and combustible metals

No single agent will control or extinguish fires in all combustible metals

The organization charged with independently testing and certifying fire extinguishers is

Underwriters Laboratories UL

What extinguishing agent interferes with the chemical chain reaction and terminates the combustion process

Halon replacement agents

How should an extinguisher with a sixth nozzle be carried When approaching a fire

In the favored hand

Best position to attack a fire with a portable extinguisher

Upwind with an exit behind you

AFFF distinguishing agents are applicable for both

Class A and B fires

When applying dry powder to a Class D fire the operator will need to

Use large amounts of dry powder to completely cover the burning material