Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
38 Cards in this Set
- Front
- Back
Max Runway Slope
|
+/- 2%
|
|
Mmo
|
.92 mach
|
|
Mmo RVSM
|
.90
(.87 if less than 520K lbs) |
|
Max Take-off & Landing Tailwind
|
10 knots
|
|
Max T.O. & Landing crosswind
|
30 kts (Manual)
15 kts Autoland (not authorized) |
|
Nose & Side Cargo Door Wind Limits
|
40 knots operation. 65 knots open.
|
|
Maximum altitude for Take-off & Landing.
|
10,000 feet
|
|
Max Operating Altitude
|
45,100 feet
|
|
Severe Turbulent Air Penetration Speed
-100 & -200 |
-100: 280-290 IAS/.82-.85*
-200: 290-310 IAS/.82-.85* *Which ever is lower |
|
Landing Gear Operating Speed (Vlo)
|
270 KIAS
Vlo Extend/Retract 270/250 (N487,N488,N489,N490) Mmo .82 |
|
Max Landing Gear Extended Speed (Vle)
|
320 kts (.82 mach)
|
|
1 Generator Isolated Max Load
|
54 KW (81 KW 5 Mins)
|
|
2 Generators Paralleled Max Load
|
81 KW Total
|
|
3 or 4 Generators Paralleled Max Load
|
51 KW Each.
|
|
AC Volts
|
115v +/-5v
|
|
AC Frequency
|
400 +/- 5hz
|
|
Max TR Load
|
75 Amps (continuous)
93 Amps (30 mins) 113 Amps (5 mins) 54 Amps (No cooling air) |
|
APU egt limits
|
Starting 990 / 900* deg
Continuous 657 / 670* deg *w/lower limit scale installed |
|
APU start limits
|
1 minute ON, 5 minutes off. 3 attemps P/Hr
61-90 sec ON, 15 minutes OFF. 2 attempts P/Hr |
|
APU inflight use
|
Below 15Kft (or 20K ft of placarded)
No ops in Icing cond. Elec pwr not permitted |
|
Hydraulic press normal psi range.
|
2800 - 3200 psi
|
|
Hydraulic ADP on @ what psi
|
2600 psi
|
|
Hydraulic Low Press light on @ what psi
|
1200 psi
|
|
Hydraulic Press Relief @ what psi
|
3450 - 3650 psi
|
|
Brake accumulator air charge psi
|
750 psi
|
|
Min Hyd fluid Qty's eng's 1,2,3,4
|
1: 7.5 qts
2: 4 qts 3: 4 qts 4: 7.5 qts |
|
Minumum N1 w/Nacelle Anti-ice on
|
50% N1 @ or above 10k ft
45% N1 below 10k ft 70% N1 if no hi-stage bleed avail |
|
Vmo
|
378 @ Sea Level
|
|
Engine oil quantity
|
Maint Sta. Enrt Sta.
JT9 Full/7gal Half/4gal CF6 Full/22qts 3.25 gal |
|
Max Starter re-engage
|
20% N2 (both)
|
|
Start Limits JT9
|
10 min ON/ 10 min OFF
15 min ON/ 15 min OFF Max 3 attempts in 10 min |
|
Start Limits CF6
|
5 minutes cont.
|
|
EGT Limits 7A
|
T.O. 5min: 915
Continuous: 875 Start: 650 Acceleration: 915 |
|
EGT LImits 7F
|
T.O. 5min: 950
Continuous: 910 Start: 650 Acceleration: 950 |
|
EGT LImits 7J
|
T.O. 5min: 985
Continuous: 925 Start: 650 Acceleration: 985 |
|
EGT LImits CF6
|
T.O. 5min: 945
Continuous: 910 Start: 750 Acceleration: 960 |
|
DC volts
|
Battery & TR: 25-32 volts
APU Battery: 25-36 volts Battery minimum: 22 volts |
|
Landing gear extended speeds
|
Vle: 320 KIAS