23 Cards in this Set

  • Front
  • Back

Close - S/V On, Vacant/NOH (moving), R<2CFH

Elec Test, Get Mtr # and Read, R check <2 CFH Leave Gas ON and complete order "Read Only" (Soft Close), Form 6552 -- Gas is On Tag

Close - S/V On, Vacant/NOH, R>2CFH

Elec Test, Get Mtr # and read, R Check >2CFH, Turn gas OFF and install clamshell or barrel, complete order as "Installed Clamshell" (hard close), DO NOT LEAVE FORMS, Document why closed (excessive R)

Close - S/V On, New Occupant Home

Test elec, get mtr # and read, R check (make sure they turn appliances off while safety checking), get name # and move in date, inform 72 hours to call CCC to complete application, leave form 6552 (Gas On) and 3853 (Home Energy and Safety Guide), Hot add turn on + complete Close as "Read Only" and Turn-On as "On No Entry" orders.

Close - S/V On, Existing Customer Not Moving

Cancel order (Code 60), document in "Remarks" name of person canceling

Close - S/V On, Existing Customer Not Ready

Mark as "Incomplete - Futured", refer to CCC enter appropriate date, document name in Remarks

Close - S/V Off, Unsecured MSA

Elec test, mtr # and read, install clamshell, doc "Found Off" and complete as "Installed Clamshell"

Close - S/V Off, Secured MSA

Elec test, mtr # and read, incomplete "Ducplicate Order" and input

Close - S/V off, New Occupant Requests Service

Elec test, mtr # and read, secure MSA and refer to CCC and complete close order as "Installed Blank"

Fumigation Close -- 7 Steps

1. Inspect MSA and riser (incomp if dmg) 2. Close S/V, disconnect mtr 3. Check pressure from inlet, record F + LU, change Kreg 4. Blank inlet, reconnect 5. Soap entire MSA and RFA if S/V leaking 6. Locking device 7. Complete order, form 5400 on MSA above S/V and front door

Gas Flow on Header

S/V, Reg, Meter Valve, Meter

1. F and LU OPP 2. F and LU non-OPP 3. rlxn to orifice 4. PSI reg diaphragm unseats

1. 7-9, <12''WC 2. 7-10, <1.5x F 3. F = demand of gas, open orifice LU = no demand, orifice fully closed 4. 14

Purpose of reg vent

allow air to enter/exhaust above diaphragm

Reg Pressure building

valve disc or seat may be dirty, orifice damaged

What are PCBs? What do to when found?

Polychlorinated Byphenyls, any liquids found in facilities, CALL SUPERVISOR

Customer experience (3 elements)

Customer Service (def by provider), Customer Satisfaction (def by customer), customer loyalty (cont'd buisness)

Missed timed appt's: HBI & CSO, all other

$50.00, $25.00 ; audited, must have finish remarks if not on time

metal connection elements

anode > electrolyte > cathode = metal cxn

Methods to reduce corrosion

protective coating, elec insulation, cathodic protection

cathodic protection

anodes attach to service line underground, forcing current to become negative and corrode anode rather than gas pipe

AL Riser Inspection: when inspected? IDs? process and criteria? No-Go Gauge?

Tool type orders. AL tag, black/green sleeve, tapered (weld), locating wire, casing crimp cxn, FBE coating, perfection (bulges). Inspect (soap, 1/2'' clearance below weld or 1'' down dmg part, remove tags and tape, verify no AOCs), coat (gauge test, clean, primer and wrap). If gauge slides through and not leaking, FUP and spray black paint

AL Riser Casing

steel tubing that houses and protects AG portion of PE and provides structural integrity

AL Riser Vertical Protective Sleeve

loose fitting plastic tube to protect vs external dmg such as landscaping

"Heavy Rust"

steel piping that is extensively corroded and/or deeply pitted