WHAT ARE 4 WAYS TO ACTIVATE THE APC SYSTEM?
-REMOVE CONTROL BOX-PRESSURE RELEASE CONTROL BOX-LEVER ON APC BOTTLE-LINK MELTS @ 360 DEGREES F
HOW MANY DEBALLASTING AIR COMPRESSORS ARE ON BOARD?
10 TOTAL ON BOARD
WHAT DO THE DEBALASTING AIR COMPRESSORS DO?
PROVIDE 7 TO 20 PSI OF HIGH VOLUME AIR THAT PRESSURIZES TANKS TO PUSH WATER OUT OF SEA CHEST VALVES
HOW MANY SEWAGE EJECTOR PUMPS ARE ON BOARD?
6 TOTAL
WHAT ARE THE TYPES OF SEWAGE EJECTOR PUMPS?
EDDY PUMPS & MACERATOR PUMPS
WHERE ARE THE SEWAGE EJECTOR PUMPS LOCATED?
2 EDDY PUMPS FOR FWD TANK2 EDDY PUMPS FOR AFT TANK2 MACERATOR PUMPS FOR SEWAGE & RECEIVING
WHAT IS THE M256A1?
A MAN-PORTABLE DETECTION KIT TO DETECT NERVE, BLISTER AND BLOOD AGENTS
WHAT EQUIPMENT IS USED TO CLEAN CHT SPILLS?
-POOPY SUITS-CHEMICAL GLOVES-FIREFIGHTING BOOTS-BANIDINE SANITIZER
WHAT ARE EFFECTS OF BLOOD AGENTS?
CASUALTY AGENT THAT EFFETCTS THE TRANSFER OF OXYGEM FROM BLOOD CELLS
WHAT ARE THE 4 PRINCIPLES OF INVESTIGATION?
CAUTIOUS
THOROUGH
REPORT
REPEAT
WHAT DOES CMWD STAND FOR?
COUNTER MEASURE WASH DOWN
WHAT IS THE PURPOSE OF THE CMWD?
TOTAL OUTSIDE SURFACE COVERAGE WASH TO CLEAR AWAY SOLID AND LIQUID CHEMICAL AND BIOLOGICAL THREATS
HOW MANY ZONES ARE IN THE CMWD?
12 ZONES
WHAT IS SPECIAL ABOUT CMWD ZONES 2 AND 3?
COVERS THE TOPS OF SUPER STRUCTURES
WHAT IS IPDS?
AN INSTALLED VAPOR SYSTEM SENSOR THAT DETECTS NERVE AND BLISTER AGENTS
WHAT IS JBPDS?
AN INSTALLED AUTOMATIC DETECTOR THAT DETECTS BIOLOGICAL AGENTS IN REAL TIME
WHAT ARE THE CAPACITY OF THE CHT TANKS?
FWD 26,162 GALLONS
AFT 27,496 GALLONS
SEWAGE AND RECEIVING 295 GALLONS
WHAT DOES ACPG STAND FOR?
ADVANCED CHEMICAL PROTECTIVE OUTER GARMENT
WHAT IS THE PURPOSE OF THE ACPG?
TO PROTECT FROM CBRN HAZARDS
WHAT IS THE ACPG MADE OUT OF?
NYLON COTTON POPLIN OUTER SHELL
HOW MANY AFFF SPRINKLER GROUPS AND ZONES?
30 SPRINKLER GROUPS (INTERNAL)
12 SPRINKLER ZONES (FLIGHT DECK)
WHAT IS THE CLASSIFICATION FOR BETA RADIATION?
CAN TRAVEL 10 FEET
UNIFORM IS SUFFICIENT PROTECTION
CANNOT PENETRATE THE SHIP’S HULL
HOW MANY MAIN AND SECONDARY DRAINAGE EDUCTORS ARE ON BOARD?
7 MAIN DRAINAGE EDUCTORS
19 SECONDARY DRAINAGE EDUCTORS
HOW MANY GALLONS DOES EACH AFFF STATION HOLD?
2000 GALLONS
WHAT IS THE PURPOSE OF RADIACS?
USED TO DETECT AND/OR MEASURE THE PRESENCE OF RADIATION
PURPOSE OF THE AN/PDQ-1 (IM-265)
A PORTABLE MONITORING DEVICE THAT DETECTS RADIATION
WHAT IS THE CLASSIFICATION OF NEUTRON RADIATION?
CAN TRAVEL THOUSANDS OF YARDSWILL PENETRATE SHIP’S HULLUNIFORM DOES NOT PROTECTEXTERNAL HAZARD AFTER 1ST MINUTE AFTER BURST
WHAT IS THE DIFFERENCE BETWEEN PATHOGENS AND TOXINS?
PATHOGENS ARE MICROBES THAT CAUSE DISEASESTOXINS ARE SUBSTINCES PRODUCED BY ORGANISMS THAT ARE HARMFUL TO HUMANS
WHAT DOES CBRN STAND FOR?
CHEMICAL BIOLOGICAL RADIOLOGICAL NEUCLEAR
HOW MANY AFFF STATIONS ARE ONBOARD?
6 TOTAL
WHAT IS THE PURPOSE OF THE HPUS?
PROVIDE HYDRAULIC POWER FOR THE SEA CHEST VALVES
AT WHAT LEVEL OF PSI DO THE HPUS OPERATE AT?
350 TO 700 PSI
WHAT ARE THE 4 TYPES OF RADIATION?
ALPHA
BETA
GAMMA
NEUTRON
WHERE ARE APC SYSTEMS LOCATED ON THE SHIP?
CREW GALLEY
CPO GALLEY
WARDROOM GALLEY
FLAG GALLEY
CO’S GALLEY
BAKE SHOP
WHAT ARE THE CPS BOUNDRIES?
ZONE 1-FRAMES 1-33
ZONE 2-FRAMES 33-49
ZONE 3- FLIGHT DECK TRIAGE
ZONE 4-CIC
ZONE 5-MEDICAL AND TROOP BERTHING
ZONE 6-REST OF MEDICAL

WHAT ARE THE EFFECTS OF NERVE AGENTS?
DISRUPTS THE TRANSMISSION OF NERVE IMPULSES
WHAT DOES APC STAND FOR?
AQUEOUS POTASSIUM CARBONATE
WHAT ARE DRAFT MARKINGS?
NUMBERS ON THE OUTSIDE SKIN OF THE SHIP THAT SHOWS HOW DEEP THE SHIP IS IN FEETNUMBERS ARE 6 INCHES TALL, 6 INCHES APART
WHAT IS THE HALON SYSTEM ACTUATED BY?
5 IB CO2
WHAT DOES MOPP STAND FOR
MISSION ORIENTED PROTECTIVE POSTURE
WHAT IS CLASSIFIED AS BLACK WATER?
WATER FROM COMMODES AND URINALS
WHAT ARE AFFF STATION TANKS MADE OF?
90% COPPER
10% NICKEL
WHERE ARE THE FIRE PUMPS LOCATED?
1,2,3 AND 4= FWD FIRE PUMP ROOM
5 AND 6= FWD MMR
7 AND 8= AFT MMR
9,10,11 AND 12= AFT FIRE PUMP ROOM
WHAT ARE THE PUMP RATES OF THE FIRE PUMPS?
FWD AND AFT FIRE PUMP ROOM= 1000 GPMFWD AND AFT MMR= 2000 GPM
WHAT ARE THE EFFECTS OF BLISTER AGENTS?
CAUSES DAMAGE TO THE BODY TISSUE AND SEVERE PAIN
WHAT ARE EFFECTS OF TEAR AGENTS?
INCAPACITATES BY IRRITATING THE EYES
HOW MANY KITS ARE IN THE M256A1?
12 INDIVIDUALLY PACKED KITS
WHAT ARE EFFECTS OF CHOKING AGENTS?
CASUALTY AGENT THAT EFFECTS BREATHING AND EFFECTIVENESS OF THE LUNGS
WHAT ARE EFFECTS OF VOMITING AGENTS?
USED TO INCAPACITATE WITH SEVERE VOMITING
WHAT DOES CHT STAND FOR?
COLLECTION, HOLDING AND TRANSFER
HOW MANY REPAIR LOCKERS DOES WASP HAVE? HOW MANY ARE USED?
10 TOTAL ON BOARD, ONLY 8 ARE USED
WHAT ARE THE TWO TYPES OF WASTE WATER?
BLACK WATER- SOIL DRAIN
GREY WATER- WASTE DRAIN
WHAT DOES JBPDS STAND FOR?
JOINT BIOLOGICAL POINT DETECTION SYSTEM
WHERE WOULD YOU FIND AN APC SYSTEM ATTACHED TO?
DEEP FAT FRYERS AND DONUT FRYERS
WHAT IS THE PURPOSE OF THE SHORE CONNECTION RISERS?
USED TO CONNECT HOSES FROM THE SHIP, TO SHORE FACILITIES TO PUMP WASTE WHILE IN PORT
WHO CANNOT USE THE M256A1
COLOR BLIND PERSONNEL
HOW MANY SHORE CONNECTION RISERS ARE THERE? WHERE?
4 TOTAL
2 PORT
2 STBD
WHAT TYPE OF FIRE MAIN IS USED ON WASP?
SINGLE LINE, SINGLE LOOP COMPOSITE
WHAT ARE THE 3 TYPES OF TANKS?
ABOVE WATER LINE TANKS
PARTIALLY ABOVE WATER LINE TANKS
BELOW WATER LINE TANKS
WHAT ARE THE 3 MODES OF OPERATIONS FOR WASTE?
IN PORT- SHORE SERVICES
TRANSIT- HELD IN TANKS
AT SEA- 3 NAUTICAL MILES AWAY FROM SHORE, DUMPED OVERBOARD
WHERE ARE THE 3 PLACES THE CMWD CAN BE ACTUATED, AND BY WHO?
DAMAGE CONTROL CENTRAL= DCABRIDGE= NAVIGATORPRIMARY FLIGHT CONTROL= AIR BOSS
WHAT IS M8/M9 PAPER?
CHEMICALLY TREATED PAPER THAT DETECTS LIQUID NERVE AND BLISTER AGENTS
WHAT ARE BATTLE DRESSING STATIONS?
READY MADE COMPARTMENTS, PLACED STRATEGICALLY THROUGHOUT THE SHIP, FOR QUICK ACCESS TO WOUNDED PERSONNEL
HOW MANY SPACES ARE PROTECTED BY HALON?WHAT TYPES?
15 SPACES TOTAL60 SECOND AND 30 SECOND TIMER DELAY TYPES
HOW DO ABOVE WATER LINE TANKS OPERATE?
FILLED WITH FIRE MAINDRAINED BY HYDRAULICALLY OPERATED SEA CHEST VALVES
HOW LONG CAN THE ACPG LAST IN A CONTAMINATED ENVIRONMENT, NON CONTAMINATED ENVIRONMENT AND WHEN SEALED?
24 HOURS IN A CONTAMINATED ENVIRONMENT45 DAYS IN A NON-CONTAMINATED ENVIRONMENT5 YEARS IN THE SEALED BAG
WHAT SPACES ARE PROTECTED BY THE 60 SECOND TIME DELAY HALON SYSTEM?
FWD MMR
AFT MMR
AUX MMR
CARGO HOLD 10
HOW DO BELOW WATER LINE TANKS OPERATE?
FILLED BY SEA CHEST VALVESDRAINED BY SEA CHEST VALVES AND LOW PRESSURE, HIGH VOLUME AIR
WHAT MASK AND CANISTER DOES WASP USE? HOW MANY/WHAT TYPE OF THREADS ON THE CANISTER?
WASP USES THE MCU-2P MASL, C-2 CANISTER AND HAS 3 NATO STANDARD THREADS
WHAT IS THE CLASSIFICATION OF ALPHA RADIATION?
RANGE OF 0-2 INCHES
CANNOT PENETRATE HUMAN SKIN
INTERNAL HAZARD ONLY
WHERE ARE THE 3 TANKS USED FOR CHT?
FWD 6-37-0-W
AFT 5.5-73-1-W
SEWAGE & RECEIVING 3-113-6-W
WHAT ARE HAZARDS OF CHT?
FLOODING
HYDROGEN SULFIDE GAS(H2S)
WHERE ARE THE MAIN DRAINAGE EDUCTORS LOCATED?
2 IN FWD MMR
2 IN FWD JP5
3 IN AFT MMR
WHAT DOES CPS STAND FOR?
COLLECTION PROTECTION SYSTEM
WHAT DOES SEWAGE AND RECEIVING DO?
COLLECTS AND TRANSFERS ONLY
CANNOT PUMP OVERBOARD
WHERE ARE THE DEBALLASTING AIR COMPRESSORS LOCATED?
2 IN FWD DEBALLAST AIR COMPRESSOR ROOM
5 IN AMR
3 IN AFT DEBALLAST AIR COMPRESSOR ROOM
HOW MANY AND WHAT INJECTORS ARE GIVEN FOR A NERVE AGENT ATTACK?
3 ATROPINE AUTO-INJECTORS
3 2-PAM CHLORIDE AUTO-INJECTORS
HOW MANY BALLASTING TANKS ARE LIST CONTROL TANKS?

8

HOW MANY BALLASTING TANKS ARE SUPPLEMENTARY TANKS?

20

HOW MANY BALLASTING TANKS ARE RAPID BALLAST TANKS?

6

WHAT ARE THE THREE TYPES OF BALLASTING TANKS?
RAPID BALLAST TANKS
LIST CONTROL TANKS
SUPPLEMENTARY TANKS
HOW MANY SALT WATER BALLASTING TANKS DO WE HAVE?

34

WHAT ARE 4 WAYS TO COMMUNICATED WITH REPAIR LOCKERS?
SOUND POWERED TELEPHONES
J-DIALS
MESSENGER
REPORTING TO THE LOCKER YOURSELF
WHAT DOES CPS PROVIDE?
PROVIDES FILTERD AIR FOR A CBRN ENVIRONMENT
WHAT TYPE OF CHT SYSTEM DO WE HAVE ON WASP?
GRAVITY FED COLLECTION HOLDING AND TRANSFER SYSTEM
WHAT IS THE PUMP RATE OF AFFF STATIONS?

65 GPM

WHAT IS CLASSIFIED AS GREY WATER?
DECK DRAINS, SINKS, SHOWERS, GALLEY/SCULLERY AND LAUNDRY TYPE WASTE WATER
WHAT IS THE PURPOSE OF THE M291 KIT?
DECONTAMINATES LIQUID CHEMICAL AGENTS FROM EXPOSED SKIN BY PHYSICAL REMOVAL, ABSORPTION AND NEUTRALIZATION
HOW DO PARTIALLY ABOVE WATER LINE TANKS OPERATE?
FILLED WITH FIRE MAIN BY SEA CHEST VALVESDRAINED BY SEA CHEST VALVES AND LOW PRESSURE, HIGH VOLUME AIR
WHAT DOES IPDS STAND FOR?
IMPROVED POINT DETECTION SYSTEM
WHAT IS THE CLASSIFICATION OF GAMMA RADIATION?
CAN TRAVEL THOUSANDS FO YARDS AND WILL PENETRATE THE SHIP’S HULLWHOLE BODY HAZARD
WHAT DOES HPU STAND FOR?
HYDRAULIC POWER UNIT
HOW MANY HPU ARE ON BOARD AND WHERE ARE THEY LOCATED?
2 TOTAL
LOCATED IN DC CENTRAL AND WELL DECK CONTROL
HOW MANY AND WHAT TYPE OF FIRE PUMPS ARE ON BOARD?
12 SALT WATER FIRE PUMPS (ELECTRICAL)
WHAT MAKES UP AFFF?
94% WATER
6% AFFF CONCENTRATE
HOW MANY DECON STATIONS ARE THERE? WHERE?
5 TOTAL#1 PORT SIDE OF GYM
#2 STBD SIDE OF 01 MARINE BIRTHING
#3 FLIGHT DECK TRIAGE, 03 LEVEL
#4 FWD OF HANGAR BAY, STBD SIDE
#5 02 LEVEL AFT, PORT SIDE
WHAT SPACES ARE PROTECTED BY THE 30 SECOND TIME DELAY HALON SYSTEM?
HAZMAT RECYCLING CENTER, FWD DIESEL, AFT DIESEL, FWD JP-5 PUMP ROOM, AFT JP-F PUMP ROOM, SHIP’S STORE FLAMMABLE LOCKER, AVIATION FLAMMABLE LOCKER, LCAC PUMP ROOM, PAINT MIXING & ISSUE ROOM, SUPPLY STORE ROOM, AVIATION FLAMMABLE STORE RM
WHAT DOES HALON GIVE OFF AT 900 DEGREES F
HYDROGEN BROMIDEFREE BROMINEHYDROGEN FLOURIDE
WHAT IS THE NORMAL STEAMING DRAFT?
25’ 6” FWD
26’ 0” AFT
WHAT IS MAXIMUM BALLASTED DRAFT?
20’ 0” FWD
40’ 0” AFT
WHAT AFFF SYSTEM DO WE HAVE ON BOARD?
BALANCED PRESSURE PROPORTIONING SYSTEM TYPE 2
(BAD PARENTING PROMOTES STUPID TEENAGERS)
WHERE IS FWD BATTLE DRESSING STATION?
MAIN DECK, PORT SIDE, FWD
WHERE IS THE AFT BATTLE DRESSING STATION?
MAIN DECK, PORT SIDE, AFT HANGAR BAY
WHERE IS THE 03 LEVEL BATTLE DRESSING STATION?
FLIGHT DECK TRIAGE
WHERE IS THE MAIN BATTLE DRESSING STATION?
MEDICAL
WHAT ARE THE 8 REPAIR LOCKERS?
1H, 2F, 2M, 3, 4, 5M, 5A, 6/7F
WHERE IS LOCKER 4 LOCATED?
AFT OF PORT SIDE SCULLERY
WHERE IS LOCKER 5M LOCATED?
STBD SIDE OF MESS DECKS
WHERE IS LOCKER 2M LOCATED?
FWD OF POST OFFICE
WHERE IS LOCKER 2F LOCATED?
02 LEVEL, FWD OF GYM
WHERE IS LOCKER 3 LOCATED?
PORT SIDE, MID SECTION OF HANGAR BAY
WHERE IS LOCKER 1H LOCATED?
STBD SIDE, AFT OF HANGAR BAY
WHERE IS LOCKER 5A LOCATED?
PORT SIDE, AFT OF CO’S LADDERWELL
WHERE IS LOCKER 6/7F LOCATED?
STBD SIDE OF OFFICER COUNTRY

WHAT IS THE PURPOSE OF MOPP AND HOW MANY LEVELS?
LEVELS SET TO PROTECT PERSONNEL FROM CBRN
THREATS
5 LEVELS TOTAL
WHAT OCCURES AT MOPP 1?
TEST ALL DETECTION AND MONITORING SYSTEMSINVENTORY ALL CBRN EQUIP/MEDICAL SUPPLIES AND NOTE SHORTAGESAT MINIMUM, ENFORCE MATERIAL CONDITION YOKE
WHAT OCCURES AT MOPP 2?
CARRY PROTECTIVE MASK AT ALL TIMESTEST CMWD, ALARMS AND ISSUE DOSIMETERSMATERIAN CONDITION MODIFIED ZEBRA ENFORCEM8/M9 PAPER POSTED BY EACH REPAIR LOCKERSHIP CREW TRAINED IN POSSIBLE SITUATION
WHAT OCCURES AT MOPP 3?
SET GENERAL QUARTERS & MAT COND ZEBRADON PERSONNEL PROTECTIVE SUIT, CARY GLOVES AND MASK WITH A NEW C-2 CANISTER INSTALLEDWARM UP RADIACSACTIVATE CMWD AND MONITOR M8/M9 PAPERDECON STATIONS SHALL BE ACTIVATED
WHAT OCCURES AT MOPP 4?
STOP BREATHINGDON MASK, DON HOOD/GLOVESCMWD SHALL RUN CONTINUOUSLYMAT COND CIRCLE WILLIAM SETMAX PERMISSABLE EXPOSURE LIMITS MONITOREDMANDATORY DRINKING WATER REGIMEN PLACED
WHAT OCCURES AT MOPP 0?
INSPECT, SIZE, FIT AND ISSUE IPE TO ALL PERSONNEL