Plungers for halon

1st- alarms (red light, siren)


2nd- ventilation shut down


3rd- halon discharge

3

Halon power panel light indicators

White- power available


Amber- activated


Red- discharged

3

2 gases halon breaks up when it decomposes at 900°

Hydrogen Bromide


Hydrogen Flouride

Halon chemical name and # of locations


Bromo trifluoro methane


8

Halon replaced what

1211


Bromo chloro difluro methane

Repair lockers on 2nd deck

DC deck


Rep 4 wd of dispatch


Rep 5 near port side chow line


Rep 2 near female eng berthing


Rep 3 sup male berthing

Repair lockers in HB

1 foxtrot- fwd HB 1


1 bravo- mid HB 2


1 alpha- aft HB 3

Repair lockers on 03 level

Gallery deck


7 foxtrot near V2 male berthing


7 bravo near ATO


7 alpha near female deck berthing

Halon activated by what and how

5 lb CO2 bottle...pull pin, squeeze handle, discharge in 60 secs in manned and 30 secs in unmanned


Presurized by nitrogen

2 locations to activate halon

Local- directly outside space


Remote- furthest point away from space usually 2nd deck

Halon breaks chemical chain reaction

Separates oxygen heat n fuel

For a good halon discharge..

Soak for 15 minutes


Ventilation time 15 minutes

Afff means?

Aqueous film forming foam

Afff ratio and operation

94%sea water 6%afff concentrate


Push button (remote)


SOPV


Motor controller (local)

Afff station locations

All 20 r on 2nd deck, 10 starboard-odd 10 port-even

M-8 paper response time and color indicators

20 seconds


Green= V nerve


Yellow= G nerve


Red= H blister

M-9 paper response time and color

10 seconds, red

Agent indicator kit

M256A1 kit


Detects agents in vapor form


nerve star *


blood circle


blister square


lewisite


12 sampler detectors, 1 book of m8 paper and a set of operational instruction cards

MOPP means and # of levels

Mission oriented protective posture


5 levels

0-2 levels of MOPP

0= no danger of attack


1= gear issued n stowed at battle stations


2= mask is carried on person, M8&9 paper posted

3-4 levels of MOPP

3= GQ is called


4= mask is donned along with entire JSLIST

4 categories of chemical agents

Blood


Blister


Choking


Nerve

4 types of radiation

Alpha


Beta


Gamma


Neutrons

Protective mask used for CBR

MCU-2P

JSLIST means what, shelf life, composed of

Joint service lightweight integrated suit technology


5 years


Trousers, coat, boots, gloves, glove inserts

C-2 cansiter- training indicator


white stripe

C-2 cansiter


Contaminated life span


Uncontaminated life span

30 days


60 days

Shoring 2 types

Metal and wood

Metal shoring types

3-5ft compressed 20,000lbs extended 12,000 lbs



6-11ft compressed 20,000 lbs extended 6,000 lbs

Wood shoring types

Yellow pine


Douglas fir


Hemlock


Spruce

4

Shoring length calculation

30 times the minimum butt thickness

Wedge length calculation

6 times the minimum butt thickness

Shoring methods

Direct compression =i type


Cross axial = H type


Triangulation = K type- keep V angeles between 65 and 90 degrees

Pipe patching types

Soft patch


EWARP


jubilee


Banding patch

Pipe patching- soft patch psi, materials, used on?

Rated at 150 psi


Rubber gasket, marlin, oakum, wedges


Utilized on fresh/salt water systems

Box fan- voltage, rated, weight and use with what

115V, 3200 CFM, use with smoke curtain and door bar

Ram fan- rated/psi, max rate/psi, weight, safety feature, and use with what

Firemain, 2000CFM @150 psi, 3250 CFM @250 psi, 35lbs, attach grounding clamp to bare metal to prevent static electricity, use with trunk- WSOA - water smoke overboard apparatus

P-100__ fuel, rated/psi/suction, purpose, hours

JP-5/DFM, rated @100gpm @83 psi with 20ft suction lift, primary firefighting, secondary dewatering, 2.75 hours of operation

PECU-means, used for, powered by, driven by

Portable exothermic cutting unit, used to access difficult space to indirectly combat casualties or rescue ppl, battery powered, oxygen driven

standard firefighting hose

50 ft


1.5 "and 2.5"


Known as cotton jackets

NFTI- means, type, battery

Navy firefighting thermal imager, K90 Talisman,


Cannot see through glass


2 batteries- rechargeable 4.85 hrs and AA lasts 3.05 hrs

PKP means and sizes

Potassium bicarbonate


18lb/19ft/10 secs


27lb/21ft/11 secs

CO2 means and size

Carbon dioxide


15lb/4-6ft/45secs

AFFF size

2 1/2 gals/15ft/55-65 sec

Class alpha

White smoke, ash producing


Paper clothes fiberous textiles humans


pri- firemain, sec- co2 for small fires

Class bravo

black smoke


DFM, JP5, lube oil, hydraulic fluid


use AFFF, pkp, halon 1301

Class charlie

smoke


Arcs and sparks, white smokeEnergized electrical equipment


Energized electrical equipment


Pri- CO2, sec- firemain in fog pattern

Class delta

Combustible metals at 1400 °F


Magnesium, titanium, powdered aluminum


Jettison and AFFF to cool

Vari nozzle patterns and GPM

Wide angle fog


Narrow angle fog


Solid stream


Flush


95 GPM inside


125 GPM outside

Fire tetrahedron

Heat fuel oxygen uninhibited chemical chain reaction

SCBAs- means and type


Self contained breathing apparatus


Carbon fiber bottles r grey

SCBAs- sizes

30 min- investigators, boundryman, gas free eng, electricians


45 min- scene leader, team leader, nozzleman, accessman, hoseman, plugman

SCBAs- rated, regulators

4500 psi, grade D air minimum of 4000psi


1st stage regulator reduces to 100 psi


2nd stage regulator reduces to .05 psi

HUD- means, lights, battery

Heads up display


2 green 75-100%


1 green 50-75%


1 amber 25-50%


1 red 0-25%


1 red circle low battery


2 AA batteries

Assistant damage control assistant- ADCA

ENS Graves

DC watch station in DCC

Damage control watch supervisor

Fire triangle

Heat oxygen fuel

Stages of a fire

Growth


Fully developed


Flash over


Decay

Ways to desmoke

Portable


Natural


Installed


Vari nozzle technique

4

AFFF tanks- #of gals, comprised of

600 gallons


90/10 copper/nickel

AFFF reserve tanks locations and gals

Fdw- HB1 port side above o2n2


Aft- HB 3 stbd side above o2n2


Holds 3500 gals of afff concentrate

AFFF injection pumps

Sends AFFF to flight deck


Stations 1,2,11,12

AFFF proportioner pump

Send AFFF to everywhere else throughout ship

AFFF locations

HB sprinklers, weps elevation sprinklers, pump rms 1,2,3, 1B shaft alley, main soace bilge sprinkling, AFFF hose reels, incinerator

AFFF transfer pumps

1 inboard of AFFF #6


2 outboard of AFFF #13


360 GPM

Concentrate vs mixture AFFF valve color

Concentrate is red n blue


Mixture is red n green

Hazards of AFFF

If left stagnant for extended time it can produce hydrogen sulfide H2S gas, smella like rotten eggs

Fog foam circuit

X5OJ

CO2 fixed flooding system- activate and locations

Break glass, pull red T handle until u see red on cord


All 7 locations in flammable storerooms

CO2 fixed flooding system power panel

White- power available


Red system activated

CO2 fixed flooding system plungers

1st alarms


2nd ventilation shutdown

CO2 fixed flooding system- size, displaces, location

50lb bottle lasts 60 seconds


Displaces oxygen


Fan tail- pull pin on 1st cycle and lift lever, once empty do the same in 2nd cycle

APC- means,locations, used for, activation

Aqueous potassium carbonate


Galleys


Deep fat fryers


Auto activation when fusible link melts at 360°

Chemicals found in 3 physical states

Solid


Liquid


Gas

Chemicals enter body through what

Respiratory tract


Skin contact


Eyes


Wounds/cuts

When/where are agent indicators posted

Prior to an attack near ventilation ducts, watertight accesses and as stated in ships CBR bill

MOPP decontamination stations


M-291

Clean personnel through showering with salt water and fresh water


M-291 Charcoal sheets


Clean personnel through physical removal, absorption and neutralization

Atropine and 2 PAM chloride

Used after exposure and symptoms of nerve agents 3 are issued

JSLIST last how long

45 days in uncontaminated environment


24 hours in contaminated environment

EWARP means, soak/cure time, sizes, do not

Emergency water activated repair patch


Soak 20 secs


Cure 30 minutes


Size 1is 2"×5"


Size 2 is 4"×15"


Dont apply to fuel lines/potable water, exceeding 300°/150psi

Jubilee rated

100 psi

Banding patch- rated

150psi

Pipe patching- secure, flooding, progressive

Secure pressure to pipe- mechanical isolation


Flooding is water rising faster than it can b removed


Progressive flooding is from space to space