DC loadmeter limit

0-1.03

AC voltmeter limit

110-125

DC voltmeter limit

25-30

AC frequency limitation

380-420 Hz

AC bus off light illuminates at

90 volts

The minimum voltage for battery bus is...

21 volts

The generator light illuminates at...

70 volts

The max load of the ATM generator with the cooling fan inoperative or 104*F is

.66 or 66%

The AC instruments and fuel control inverter (in ESS DC position) uses...

115 volts/400Hz in phase A

The max load of an AC engine generator is...

.72 or 72%

The rated load of the ATM with cooling fan operative is...

1.00

The suction boost pump pressure is...

70-90 psi

The auxiliary accumulator pre-charge pressure is...

300 +/- 100 psi

The utility accumulator pre-charge pressure is...

1500 +/- 100 psi

The auxiliary system pressure is...

2900-3300 psi

The booster system pressure is...

2900-3200 psi

The emergency brake accumulator pressure is...

1000 +/- 100 psi

The suction boost pump warning light will illuminate at...

20 psi

Full hydraulic system pressure will be reached within...

30 sec after on speed

The maximum system pressure for utility is...

3500 psi

The engine pump warning light will come on if the pressure drops to about...

1000 psi

The wing overheat temperature is...

200-up°F

Wing isolation valves are ______ closed/________ opened

Electrically/Manually

Minimum pressure for bleed down is...

35psi

Normal wing temperature operational range is...

75°-200° F

Inoperative wing temperature range is...

75° or below

Maximum running time for wing anti-icing is...

30 sec

GTC oil pressure switch setting is...

3 psi

GTC overspeed switch is...

110% rpm

Start light goes "out" at...

35% rpm

On speed light comes "on" at...

95% rpm

GTC starter duty cycle is...

1 on, 4 off

Bleed down check limit is...

30 to 15 psi in no less than 8.5 sec

Fire bottle pressure is...

600-640 psi

Agent discharge switch should not be held more than...

2 sec on

Turbine overheat is indicated by a...

Flashing light in the T handle

There are __ turbine overheat detectors, set at...

4, 700°F

Engine fire is indicated by a...

Steady light in the T handle

Do not hold the turbine overheat test switch more than...

30 sec on

There are __ nacelle overheat detectors, set at...

6, 300°F

Fire detection system uses...

Inconel tubing

The torquemeter shaft measures...

Engine output

Normal limiting mode is...

Less than 66° throttle and at 94% rpm

Safety coupling setting is...

-6000 in/lbs torque

The combustion section is...

Can-annular

The turbine section has...

4 stages

The compressor section is a...

14 stage axial flow

Compressor discharge pressure/temp is...

125psi/600°F

Temperature controlling mode is...

Greater than 66% throttle and at 94% rpm

Start limiting mode is...

94% rpm

Maximum allowable torque is...

19600

Crossover is at...

66° throttle