Which condition at the main panel should NOT be reported as a safety hazard?

Live current in the main panel

Which conditions SHOULD be reported as a safety hazard?

Undersized branch circuit wiring


System not grounded


Inoperable gfci

What is NOT an overcurrent protection device?

Meter

A type of box that holds splices, outlets and switches is called:

Junction box

Electricity moves along wires known as

Conductors

T/F: tapping before the main disconnect is considered an insafe practice?

True

The electrical pressure that pushes through wires is known as

Voltage

Upgrading to ___fuses stores over fusing

S

Electric dryer receptacles in older houses require

Their own circuit

T/F; all in panel electrical splices should be reported as improper

False

What method of sub-panep wiring is NOT acceptable?

Feeder wires tapped at the main disconnect in main panel

T/F: horizontal faced up countertop receptacles are permitted.

False

Whay should be reported as a problem with an electrical panel I'm regards to breakers?

Unlinked double pole breakers

Above ground cables connecting a utility pole to service entrance conductors are:

Service drop

A panel using double pole breaker to isolate 120V circuits is called:

Split bus panel

Aluminum wire size for 20 Amp is:

10 awg

Three conductors at the weatherhead. What is the nominal electric service?

Split phase 120/240 volts

How many conductors is three pgase 240 volts?

4

The larger the diameter of the conductor:

The more current it carries

Most common color coding for 240v conductors is:

Black/red for hot and white for neutral/ground

What is true about 240v breakers?

They should be tied together

Which kind of scree is the hot wire connected?

Brass

T/F: several grounded conductors can terminate on the same lug

False

What is minimum service for town home?

100 Amps

Problematic solid aluminum wiring was replaced for copper in what years?

1965-1978

Reversed polarity means

Hot and grounded are reversed

Is it code to connect aluminum wire to an outlet?

Maybe - if the outlet is rated for that wire

In Subpanel you are required to:

Isolate neutral bus and conductors from contacting the panel enclosure

Gfci functions by sensing

A current imbalance between hot (ungrounded) and neutral (grounded)

Unused breaker openings are

Dangerous and pose electrical hazard

Resistance is

Ohms

What is an unused knockout?

A fuse holder without fuse in it. When removed it exposes electrical shock

When testing gfci reset device in hall bathroom, you find that power shuts off to outlets in other bathrooms as well. You conclude that:

All these outlets are properly wired on same gfco. No correction needed.

Panel clear space measuring

30"W x 80"H x 36"D

Gfci is now required for

Garages

Zinsco is sometimes branded as

Sylvania

3 hole grounding type electrical receptacles must be

Grounded

What does service drop loop prevent?

Water entering meter base and panel

Modern branch circuit wiring is used primarily for:

Electric ovens

Besides aluminum, the most common residential wiring material is

Copper

Minimum service drop above roadway

18 ft

T/F: water dropping from panel must be investigated

False

According to NEC, gfcis need NOT be installed in

By overhead garage door opener

In New construction what would NOT be considered an electrical system defect?

#12 copper wire to 15amp breaker

If a light fixtures fails to work, what should you do?

Determine whether bulb is dead

Problematic solid aluminum was used in what years?

1965-1978 used

Common cause of arc flashes when removing panel front is from

Incorrect fasteners

Most recommended method of repairing aluminum branch circuit wiring in 1980 was

COPALUM crimp connectors to bond copper to aluminum wiring at each connection/splice