Control Rod operability reqs
Each control rod shall be OPERABLE in modes 1 & 2
One withdrawn control
rod stuck.
-Verify stuck control
rod separation
criteria are met - IMMEDIATELY
-Disarm the associated
(CRD) - 2 hrs
Control Rod Scram Times reqs
a. No more than 12 OPERABLE control rods shall be "slow,"
in accordance with Table 3.1.4-1; and
b. No more than 2 OPERABLE control rods that are "slow"
shall occupy adjacent locations.
Apllicable in modes 1&2
Control Rod Scram Accumulator reqs
Each control rod scram accumulator shall be OPERABLE.
-APPLICABILITY: MODES 1 and 2.
Two or more accumulators
inoperable with
reactor SDP > 900 psig.
-Restore charging
water header pressure
to >= 940 psig. - 20 min
AND
-Declare the
associated control
rod scram time
"slow." - 1 hr
OR
-Declare the
associated control
rod inoperable.- 1 hr
One or more control
rod scram accumulators
inoperable with
reactor SDP >= 900 psig.
-Verify all control
rods associated with
inoperable
accumulators are
fully inserted. - Immediately
-Declare the
associated control
rod inoperable. - 1 hr
Rod Pattern Control reqs
OPERABLE control rods shall comply with the requirements of
the analyzed rod position sequence.
APPLICABILITY: MODES 1 and 2 with THERMAL POWER >= 10% RTP.
Nine or more OPERABLE
control rods not in
compliance with the
analyzed rod position
sequence.
-Suspend withdrawal of
control rods. - Immediately
AND
-Place the reactor
mode switch in the
shutdown position. - 1 hr
Standby Liquid Control (SLC) System reqs
Two SLC subsystems shall be OPERABLE.
APPLICABILITY: MODES 1, 2, and 3.
Scram Discharge Volume (SDV) Vent and Drain Valves reqs
Each SDV vent and drain valve shall be OPERABLE.
APPLICABILITY: MODES 1 and 2.
MINIMUM CRITICAL POWER RATIO (MCPR) reqs
All MCPRs shall be greater than or equal to the MCPR
operating limits specified in the COLR.
APPLICABILITY: THERMAL POWER >= 25% RTP.
Any MCPR not within
limits.
Restore MCPR(s) to
within limits. - 2 hrs
One or more Functions
with RPS trip
capability not
maintained.
Restore RPS trip
capability. - 1 hr
Intermediate Range
Monitors channel reqs
a. Neutron Flux—High
b. Inop
a. 3 ch required per trip sys in mode 2
b. 3 ch required per trip sys in mode 2
Average Power Range
Monitors channel reqs
a. Neutron Flux—High,
Setdown
b. Flow Biased Neutron
Flux—High
c. Fixed Neutron
Flux-High
d. Inop
a. mode2/2 req ch per trip sys
b. mode1/2 req ch per trip sys
c. mode1/2 req ch per trip sys
d. mode1&2/2 req ch per trip sys
Reactor Vessel Steam
Dome Pressure—High reqs
modes 1&2 / 2 channels per trip sys
Reactor Vessel Water
Level—Low reqs
modes 1&2 / 2 channels per trip sys
Main Steam Isolation
Valve—Closure reqs
mode 1 / 8 channels per trip sys
Drywell Pressure—High reqs
modes 1&2 / 2 channels per trip sys
Turbine Stop
Valve-Closure reqs
>= 38.5% / 4 channels per trip sys
Turbine Control Valve
Fast Closure, Trip Oil
Pressure—Low reqs
>= 38.5% / 2 channels per trip system
Turbine Condenser
Vacuum—Low reqs
mode 1 / 2 channels per trip system
Reactor Mode Switch—
Shutdown Position reqs
modes 1&2 / 1 channel per trip system
Source Range Instrument reqs
mode 2 - 3 required
mode 3, 4 - 2 required
Three required SRMs
inoperable in MODE 2
with IRMs on Range 2
or below.
Suspend control rod
withdrawal. - Immediately
One or more required
SRMs inoperable in
MODE 3 or 4.
-Fully insert all insertable control rods. - 1 hr
AND
-Place reactor mode switch in the shutdown position. - 1 hr
One or more required
SRMs inoperable in
MODE 5.
-Suspend CORE ALTERATIONS except for control rod insertion. - Immediately
AND
-Initiate action to fully insert all
insertable control rods in core cells containing one or
more fuel assemblies. - Immediately