What is (a) required on every running trap and (b) where is it placed? |
a) a clean out b) upstream |
How would you service an issue? |
|
When a sanitary building drain changes direction more than (a) ______? (b) what is required? |
a) more than 45° b) a cleanout |
Servicing a bend |
|
Every sanitary building drain or storm building drain needs a (a) _______? (b) where? |
a) cleanout b) as close as practical to where the drain leaves the building |
|
|
Every soil or waste stack shall be provided with what type of fitting? |
A cleanout fitting |
|
|
Every soil or waste stack shall be provided with a cleanout fitting: a) _________ b)__________ c)__________ |
a) at the bottom of the stack b) not more than 1000 mm upstream of the bottom of the stack c) on a Wye fitting connecting the stack to the building drain or branch |
|