• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/50

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

50 Cards in this Set

  • Front
  • Back
  • 3rd side (hint)

Damage control states of readiness govern.

- Machinery


- Manning


- Material

3 M’s

Watertight Risk and control markings

Controls the watertight integrity of the ship

Action working dress consists of:

- General working dress


- Cotten undergarments/ socks


- boots


- antiflash


Basic fire fighting rig:

- Action working dress


- anti flash good and gloves

Intermediate fire fighting rig:

- Basic fire fighting rig


- BA

Full fire fighting rig:

- Basic fire fighting suit


-Bristol suit


- BA


- firefighting gloves


- firefighting boots


- woollen socks


- Helmet


- Minespot (head lamp)

Helicopter fire fighting rig:

- Full fire fighting rig


- Belt Hatcher


- safety knife

Who’s permission must be gained to open an X watertight door or hatch in state 3 condition X?


Where are they located?

OOW


BRIDGE

Who’s permission must be gained to open an X or Y watertight door or hatch in state 2 condition Y?

HQ1

Who’s permission must be gained to open an X, Y or Z watertight door or hatch in state 1 condition Z?

HQ1

Who’s permission must be gained to open a watertight door or hatch while alongside?


Where are they located?

OOD


GANGWAY

What are the zones of damage?

- Primary, immediate vicinity


- Secondary, surrounding primary zone


- Remote, any other areas damaged due to shock

The areas most subjected to flooding are called?

Red risk zone

What indicates a red opening?

A red triangle on the corner of the door

When the order CLOSE ALL RED OPENINGS is heard you are to:

- Close all red openings in your vicinity


- Remain where you are until piped otherwise

How do you check for fire and flood?

Fire: check for heat using the back of your hand, Do not open if fire is suspected


Flood: crack door/ hatch slowely. Look and listen for signs of flooding. Do not open if water is emitting.

Action taken on discovering a damage:

- Raise the alarm


- Take correct first aid action


- Give brief to scene leader

what is an RNZN 400?

Firefighting check off card

what is an RNZN 400?

Firefighting check off card

What information is contained on a RNZN 400

- Ventilation control


- Smoke clearance


- portable FF appliances


- Fixed firefighting appliances


- power isolations


- hazards


- pumping arrangements


- adjacent compartments


- compartment layout

What does EEBD stand for?


How long does it last?


What is it used for?


What zone should it be in?

Emergency Escape Breathing device


10 mins


Used for escape only


Should be in the green zone (200 bar)

What does DECK stand for?

-Don EEBD, place EEBD on any unconscious person and ensure they are placed in the recovery position


-Evacuate the area


-Close down the compartments and confirm last person out


-Keep high

What information would you find on a Watch and station bill?

-SSD


-SSEP


-RAS position


-Watch


-Emergency station

Emergency stations is used to bring the ship to a higher state of readiness in the event of:

- Fire


- Casualty x2


- Flooding


-Collision/ grounding


- aircraft or explosion incident


Emergency stations is used to bring the ship to a higher state of readiness in the event of:

- Fire


- Casualty x2


- Flooding


-Collision/ grounding


- aircraft or explosion incident

When emergency stations is piped the following must be carried out:

- Personnel on watch must stay on watch


- Personnel taking first aid action continue until relieved


- CBRNDC teams close up for state 1


- Remaining hands remain until ordered by command

Who are the STANDING SEA EMERGENCY PARTY?

Are personnel who take first aid action in the event of


- fire


- flood


- toxic gas incident and any other type of emergency

Who are the STANDING SEA EMERGENCY PARTY?

Are personnel who take first aid action in the event of


- fire, flood, toxic gas incident and any other type of emergency

Who are the STANDING SEA EMERGENCY PARTY?

Are personnel who take first aid action in the event of fire, flood, toxic gas incident and any other type of emergency

Special sea dutymen are used for the following occasions?

- Fog


- RAS


- Narrow waters


- Entering and leaving harbour

Fire requires 3 things to exist:

- Heat


- Fuel


- oxygen

Fire requires 3 things to exist:

- Heat


- Fuel


- oxygen

Heat can be transferred by?

Conduction


Convection


Radiation

Extinguish a fire by:

Cooling


Smothering


Starving

What are the Classifications of Fire?

CLASS A- carbonaceous solids


CLASS B- flammable and combustible liquids


CLASS C- flammable and combustible gases


CLASS D- combustible metals


CLASS E- electricity


CLASS F- combustible cooking oils and fats

AFFF fire extinguisher


Colour, time and class

Red cylinder, blue band, 45 secs, A/B/F class

Dry powder extinguisher


Colour, time and class

Red cylinder, white band, 20 secs, A/B/C/F and E in emergencies

CO2 Fire extinguisher


Colour, time and class

Red cylinder, black band, 20 secs, A/B/C/E/F

What are size 1 fire hoses size?


Where are they stored?

38 mm


Between decks


Used for firefighting between decks

What are size 2 fire hoses size?


Where are they stored?

50 mm


Upper deck


Used for firefighting upper deck

What are size 3 fire hoses size?


Where are they stored?

70mm


Flight deck


Used for firefighting flightdeck

Name the personnel in a 5 man fire fighting team and what they are dressed in and have what equipment with them?

Team leader FFR Tic, magnet, lanyard (chain)


Team protector FFR NO1 hose fitted with MRN


Fire fighter FFR NO1 hose fitted with MRN


Hose tender FFR


BA controller BA board, China graph, magnet, watch, EEBD

Containment party job consists of:

- Take action to limit smoke


- provide a TIC to the scene of the incident


- rig boundary cooling


- TMS


- establish the immediate boundary


- Remove flammable materials from the vicinity of the boundary


- minimise danger from electrical equipment


- remove or drain excess surface water

4 golden rules of firefighting?

- cool the compartment before entering


- always have TP opposite the hinges


- Always enter the compartment with waterwall on


- waterwall to be the last to leave the compartment

Name the fixed fire fighting systems used in the RNZN:

- Water spray system


- high fog


- gaseous fire fighting systems ( halon and co2)


- potassium carbonate


- wet chemical


- chemical mist


- fixed foam installations

Gas monitor measures:

OXYGEN


COMBUSTABLE GASES


HYDROGEN SULPHIDE


CARBON MONOXIDE

Rules of shoring are:

- Always use a Gunter Baton


- Always cut away from scene


- Always set a shoring watch


- Always shore against a strong surface


- Never use shoring timber more than 30 times it’s width


- Never pre cut shoring


- Never pre erect shoring

Name two reasons for shoring:

- To secure leak stopping devices


- To reinforce weakened structures

Name 2 types of shoring:

Vertical shoring


Square shoring

What is the wood used for shoring?


What are the advantages of this wood?

Oregan


It’s easy to cut, strength to weight ratio, cheap