WHEN SHOULD THE COOLANT PUMP BE OVERHAULED
EVERY TWO YEARS
WHEN SHOULD THE COOLANT PUMP BE OVERHAULED
EVERY TWO YEARS
COOLANT CAPACITIES
RADIATOR
ENGINE BLOCK
LINES
RADIATOR = 51.8 GAL
ENGINE BLOCK = 31.25
LINES = 8.25
TOTAL = 91.3
MAIN COOLANT PUMP
TYPE
GPM
RPM
CENTRIFUGAL
411 GPM @ 1800
DESRCIBE MAIN COOLANT FLOW STARTING FROM THE PUMP
COOLANT PUMP
V OF ENGINE
1ST PATH
AFTERCOOLER
THERMOSTAT
HOUSING
SECOND PATH
CYLINDER JACKETS
CYLINDER LINERS
CYLINDER HEADS
COOLANT MANIFOLD
THERMOSTAT HOUS
THERMOSTAT HOUSING
TEMPERATURE AND PATH
BELOW 170 DEGREE = COOLANT CHANNELED THROUGH BYPASS LINE
170 - 190 DEGREE CHANNELED BOTH TO BYPASS LINE AND RADIATOR
OVER 190 DEGREE = CHANNELED THROUGH SEPERATE COOLANT RETURN LINES TO RADIATOR
WHAT IS MT3
WHAT IS NORMAL OPERATING TEMPERATURE
SENDING UNIT FOR COOLANT TEMPERATURE GAGE
180 - 200 DEGREE F
CROSSFLOW HEAT EXCHANGER BTU/MIN
RADIATOR PSI TEST
RADIATOR PSI MAX
RADIATOR CAP PSI
35,800 BTU/MIN
10 PSI TEST
15 PSI MAX
7 PSI CAP PRESSURE
IMMERSION HEATER
WATT
VAC
AMP
THERMOSTATS SETTINGS
5000 WATTS
208-240 VAC
20.8 AMPS
100 - 120 DEGREE F
HOW MANY ISOLATION VALVES ON THE IMMERSION HEATER SYSTEM
THREE
WHEN SHOULD DCA FILTERS BE CHANGED
250 HOURS OR EVERY 6 MONTHS
HOW OFTEN SHOULD THE COOLANT PUMP BE OVERHAULED
EVERY 2 YEARS