28 Cards in this Set
- Front
- Back
The most common way to express level is in percent level |
false |
|
the most common way to express level in a tank |
false |
|
One tank may require a _____ tank than the other |
larger |
|
most common way when dividing point measurement is to establish high or low levels of temp |
true |
|
the greater the amount of pressure observed the _____ the level would be in a tank |
higher |
|
the interface level can be between two liquids, a liquid and a slurry, or a liquid and a solid |
false |
|
the most common way to observe a meniscus is a glass tube manometer |
true |
|
a convenient way to express the density of a material is through interface |
false |
|
formula for liquid hydrostatic head pressure |
P = (1 in. water) x (height)x (specific gravity)/ (inches) |
|
most common variable used to interfere level in industries is |
head pressure |
|
a convenient way to express the density of a material is through |
specific gravity |
|
formula for calculating the height of a liquid is |
pressure/(specific gravity) |
|
the 9 most common types of level sensing and measuring devices used in the process industry |
gauge or sight glass float tape gauge differential pressure cell' bubbler displacer ultrasonic device nuclear device load cell |
|
the two basic types of gauge glasses are |
b & d |
|
float gauge can also measure solids and the levels |
false |
|
fixed amount of mass occupies a large volume than its density has to |
decrease |
|
flow like liquids flow over one point to another depending on |
pressure and temperature |
|
fluid movement may be either ____ or __ depending on path taken |
turbulent and laminar |
|
___ can be used to identify whether a flow is laminar or turbulent |
reynold's number |
|
flow rate is measured |
indirectly |
|
mass density of any given volume of liquid depends upon its |
temperature |
|
the most common primary flow measure is ____ |
differential pressure |
|
name 5 of the most common sensing measuring devices used in a process industry |
orface plate venturi tube flow nozzle pitot tube annubar tube |
|
most common type of true mass meter is |
coriolis |
|
two kinds of flow measurements are |
flow rate and total flow |
|
to calculate the reynold's number all is needed except |
everything except d (i think d is laminar) |
|
the difference between two related pressures; usually in measurements of process variables (pressure, temp, level, and flow) |
differential pressure |
|
an upward force on a submerged body that is equal to the weight of the displaced fluid. |
Buoyancy. |