  • Front
  • Back
Four tactical phases of searching for victims
1. Surface Victim Removal
2. Void Access and Search
3. Selective Debris Removal
4. General Debris Removal
NFPA Standard on Operations and Training for Technical Search and Rescue Incidents
NFPA 1670
4 Types of Construction
1. Light Frame
2. Heavy Wall
3. Heavy Floor
4. Precast Concrete
5 Types of Collapse
1. Pancake
2. V-Shaped
3. Lean-to
4. A-frame
5. Cantilever
Oxygen level needed without supplied air
between 19.5 and 23.5
Wood's weight per cubic foot
35 lbs
Masonry's weight per cubic foot
125 lbs
Concrete's weight per cubic foot
150 lbs
Structural Steel's weight per cubic foot
490 lbs
1 three second blast
Cease Operation/All quiet
3 one second blasts
Evacuate the area
One long and one short blast
Resume Operations
Top of X
Date and Time Search team left structure
Bottom of X
Total Victims left inside
Right of X
Hazards
Left of X
Search Team name
What kind of lever is a wheelbarrow?
Class 2
What is the limit for shoring
3 times the length
How much should corners be overlapped on cribbing
4 inches
How many lbs of contact for a 4x4 cribbing
6000 lbs
Significantly Damaged
Not safe for search and rescue
Structure is accessible