20 Cards in this Set

  • Front
  • Back
  • 3rd side (hint)

Electric water heaters do not need to be honest and when located in a garage true or false

True

a water heater supported from the ground shall rest on level concrete or other approved base extended not less than blank inches above the adjoining ground level.

3 inches

Water heaters located in attics she'll have a 120 volt receptacle outlet and blank installed near the appliance

Permanent light fixture

Only a gas water heater installation requires a final inspection true or false

False

Vacuum relief valves are required when the water heater is blank the outlet level of fixtures served.

Above

When do you need to use a vacuum relief valve on a water heater

Seismic strapping for water heaters is to be on the top blank and bottom blank with a minimum of blank inches above the controls in category C D E and F

Top third and bottom third with a minimum of four in above the control

the building official shall have the authority to require the use of approved by electric insulator on the water piping connection of water heaters true or false

True it's his or her call

The minimum door opening allowed for a 30 in diameter water heater is blank inches

30 inches

All gas water heaters in garages shall be raised to a minimum of eighteen in above the floor true or false

False they don't need to if they are limited combustion

Unlisted water heater shall be a minimum clearance of 12 inches from all sides and rear true or false

True

Direct vent water heaters are never allowed to be installed in a bedroom or bathroom

False

Water heaters are limited to a maximum of blank gallons

150 gallons

What is the maximum PSI allowed for water heaters

120 PSI

Water heaters located on any wood frame assembly require a

Pan

What chapter talks about t&p valve terminations

Chapter 6 water supply and distribution

Water heaters do not require a permit when replaced like4like true or false

False

is the water heater pressure relief valve termination required to be brought up to existing code when being replaced as per state interpretation

True

A water heater is required to have a drip pan installed when replacing like4like true or false

False

are all water heaters required to be protected from physical and mechanical damage went installed in a garage Warehouse or other area subject

False instahot sand electric do not only gas

On a water heater replace is it required to upgrade combustion air to current code requirements true or false

True that's dangerous as ****