Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
9 Cards in this Set
- Front
- Back
What 2 fluids flow through the fuel heater strainer? |
Fuel and oil |
|
What action must be carried out before servicing the fuel heater strainer? |
Fire handle and relevant CB must be pulled to close Eng firewall fuel shutoff valve |
|
What are 2 faults that could cause fuel flow but no ignition? |
- HEIU failure - Igniters failure - Manifold drain valve open |
|
What are 2 functions of the FCU secondary check valve? |
- Prevents reverse flow of secondary pump back to secondary pump inlet if primary pump fails - Provides alternative inlet to primary pump if secondary pump fails |
|
What fuel system component is bypassed in the event of scroll pump failure? |
LP filter |
|
What are 2 causes of parallel light staying on above 65% rpm? |
- Primary pump failure - Paralleling pressure switch failure - Speed sense control failure - Paralleling valve jammed shut |
|
At what rpm % are the fuel pumps in series? |
0-16%, and at 65% and above |
|
What are the indications of primary pump failure? |
Paralleling light will stay on |
|
What component in the FCU is bypassed during fuel enrichment? |
Metering valve |