which of the following statements regarding fire resistance is MOST accurate?

fire resistance is the ability of a structural assembly to maintain its load-bearing capacity and structural integrity under fire conditions.

Fire resistance of structural assemblies can be determined by all of the following EXCEPT:

real fire

which of the following is a primary point of a failure of the fire resistance text?

failure to support applied load

the furnace temperature in the standard fire test is regulated to conform to the standard time-temperature

Curve

which of the following statements regarding limitations of fire tests is LEAST accurate?

the standard fire test assumes a limited fuel supply and compromised adequate ventilation

Fire rating tests provide information on

the ability of structural assemblies to act as a barrier to fire

which of the following is an organization that conducts fire resistance testing?

Southwest Research Institute

Underwriters Laboratories publishes the __annually, which lists assemblies that have been tested and their fire resistance ratings.

Fire Resistance Directory

Which of the following statements about fire resistance calculations is MOST accurate?

Mathematical equations can predict the behavior of materials under test conditions

the second digit in NFPA 220's subclassification of building types refers to the fire-resistance rating of:

structural frames or columns and girders that support loads of more than one floor

Generally, bearing walls, columns and beams of a Type I building subclassified as 4-4-2 have a fire resistance rating of:

2-4 hours

the point at which unprotected members will fail in Type II construction depends on all of the following EXCEPT:

Flooring construction

Which of the following statements about Type II construction is MOST accurate?

Materials other than steel can be used in Type II construction

which of the following statement regarding Type IV construction is MOST accurate?

concealed spaces between structural members are not allowed

which of the following statements about Type V construction is MOST accurate?

Building codes impose restrictions on the maximum heights and areas of wood frame buildings.

What is a fire load?

the maximum heat released if all available fuel in a building was consumed

the fire load is the product of the weight of the combustibles;

Multiplied by their head of combustion

which of the following statements regarding occupancy classifications is LEAST accurate?

all building codes must make use of either the NFPA or IBC codes

which of the following statement regarding mixed occupancies is LEAST accurate?

building codes require that all occupancies maintain a 1 to 3 hours separation

which of the following statements regarding a building occupancy classification is MOST accurate?

Buildings frequently undergo a change of occupancy