ANSI/SCTE 01 2006, SPECIFICATION OF “F” PORT, FEMALE, AND OUTDOOR ARE MINIMUM REQUIREMENTS FOR WHAT?
F-81 INDOOR AND DROP SPLICE BARREL CONNECTORS
WHAT TYPE OF ADAPTERS (BARREL CONNECTORS) MUST ONLY BE USED FOR TEMPORARY CABLE RESTORATION?
F 81
WHAT DOES MECHANICAL AND ELECTRICAL SPECIFICATIONS OF ANSI/ SCTE 153 2008 REFER TO?
THE MINIMUM REQUIREMENTS OF ALL PASSIVE DEVICES
________ MUST HAVE NO FIELD ADJUSTMENTS OF THE CUTTING BLADES.
DROP CABLE PREPARATION TOOL
HOW OFTEN SHOULD THE CUTTING BLADES BE REPLACED IN A DROP CABLE PREPARATION TOOL?
MONTHLY
ONLY PRODUCTS APPROVED BY __________ SHALL BE USED IN THE DROP SYSTEM.
COMCAST CORPORATE ENGINEERING
WHAT IS THE FORWARD BANDWIDTH FOR ALL PASSIVE AND ACTIVE EQUIPMENT?
54 MHZ TO 1,002 MHZ (1 GHZ)
WHAT IS THE RETURN BANDWIDTH FOR ALL PASSIVE AND ACTIVE EQUIPMENT?
5 MHZ TO 42 MHZ
ANSI/SCTE 129 2007, DROP PASSIVE REFERS TO WHAT?
ALL GROUND BLOCKS MINIMUM REQUIREMENTS
WHAT WIRE SIZES DOES THE BONDING WIRE ATTACHMENT ACCOMMODATE?
#6 TO #14 AWG SOLID COPPER
WHAT DOES ANSI/SCTE 74 2003, SPECIFICATION FOR BRAIDED 75 OHMS FLEXIBLE RF COAXIAL DROP CABLE REFER TO?
THE MINMUM PHYSICAL AND ELECTRICAL REQUIREMENTS OF ALL DROP CABLE USED FOR RF SIGNAL DISTRIBUTION
WHAT DOES ANSI/SCTE 161 2009 FOCUS ON?
THE MINMUM REQUIREMENTS OF DROP AMPLIFIERS
DROP CABLE PREPARATION TOOLS MUST HAVE A ____ IN THE DIELECTRIC CUTTING BLADE TO PREVENT NICKING OR SCORING OF THE CENTER CONDUCTOR.
NOTCH
LOCKING OR SECURITY TRMINATORS MUST HAVE A ______ TO TERMINATE THE SIGNAL.
INTERNAL 75-OHM RESISTOR
WHAT ARE THREAD PROTECTORS USED FOR?
TO PROTECT THE THREAD FROM MOISTURE CONTAMINATION
WALL PLAT MUST HAVE A_______ HEX RECESS MOLDED INTO THE F-81 AND PREVENT IT FROM TURNING.
7/16 INCH
WHY SHOULD YOU REMOVE DROP FROM PLANT WHILE CHANGING A CONNECTOR?
TO MINIMIZE INADVERTENT INJECTION OF NOISE OR INTERFERENCE INTO A LIVE NETWORK.
HOW OFTEN SHOULD YOU INSPECT YOUR COMPRESSION TOOLS?
MONTHLY
ALL CONNECTIONS, EXCEPT THOSE ON CUSTOMER PREMISES EQUIPMENT, MUST BE WRENCH-TIGHTENED TO _____ TO ______ INCH-POUNDS.
30 TO 35
WHAT IS THE AIR-SHRINKABLE TUBE USED FOR?
INSTALLED TO COVER THE F-CONNECTOR AND FEMALE F-PORT COMPLETELY
WHEN INSTALLING A TRAP TOA JUMPER WHAT MUST BE INSTALLED ON BOTH ENDS OF THE F-81 BARRELCONNECTOR TO SEAL THE TRAP AND THE F-CONNECTOR?
THREAD PROTECTORS
WHAT DOES ARTICLE 820 OF THE NATIONAL ELECTRICAL CODE REFER TO?
THE MINMUM REQUIREMNETS OF ALL AERIAL DROPS
THIS IS REFERRED TO AS AN INTEGRAL SELF SUPPORTING STRENGTH MEMBER OF AERIAL DROP CABLE.
MESSENGER
WHAT TYPE OF CABLE SHOULD BE USED FOR ALL AERIAL DROPS UP TO 150 FEET?
SERIES 6
USING SERIES-11 FOR DROPS GREATER THAN 150 FEET WILL HELP IMPROVE WHAT TO RF?
FORWARD SIGNAL LEVELS
CROSSING ------------ AND UTILITY LINES WITH THE AERIAL DROP MUST BE AVOIDED.
SWIMMING POOLS
CABLE DROPS SHOULD NEVER CROSS _______ OUTSIDE OF THE MUNICIPAL RIGHT-OF-WAY, TO AVOID CABLE TRESPASS ________ SHOULD BE INSTALLED
PROPERTY LINES: MID-SPAN
WHAT IS THE CLEARANCE FROM POWER AT THE POLE?
40 INCHES
WHAT IS THE CLEARANCE FROM PHONE PROVIDERS AT THE POLE?
12 INCHES
WHAT IS THE CLEARANCE FOR POWER AT THE MID-SPAN?
24 INCHES
WHAT I THE CLEARANCE FOR TLEPHONE PROVIDERS AT THE MID-SPAN?
6 INCHES
WHAT IS THE CLEARANCE AT THE HOUSE FOR POWER?
12 INCHES
WHAT IS THE CLEARANCE AT THE HOUSE FOR THE TELEPHONE PROVIDER?
6 INCHES
WHAT IS THE CLEARANCE FOR OVER THE ROAD,STREETS, ALLEYS; NONRESIDENTIAL DRIVEWAYS
18 feet
WHAT IS THE CLEARANCE OVER ROADS, STREETS ALLEYS; NONRESIDENTIAL DRIVEWAYS; PARKING LOTS AND OTHER AREAS SUBJECT TO TRUCK TRAFFIC?
18 FEET
WHAT IS THE CLEARANCE OVER RESIDENTIAL DRIVEWAYS SUBJECT TO TRUCK TRAFFIC?
15 FEET
WHAT IS THE CLEARANCE OVER RESIDENTIAL DRIVEWAYS NOT SUBJECT TO TRUCK TRAFFIC ?
11 FEET
WHAT IS THE CLEARANCE ABOVE SIDEWALKS OR OTHER PEDESTRIAN TRAFFIC AREAS?
10 FEET
WHAT IS THE CLEARANCE ABOVE ROOFS NOT ACCESSIBLE TO PEDESTRIANS?
3 FEET
WHAT IS THE CLEARANCE FOR ALL POINTS ABOVE A FLAT ROOF?
10.5 FEET
HOW FAR SHOULD THE SPAN CLAMP BE SPACE FOR ANY EQUIPMENT OR HARDLINE CONNECTOR?
6 INCHES
HOW FAR SHOULD THE SPAN CLAMP ON EITHER SIDE OF A POLE BE SPACED FROM THE CENTER OF THE POLE?
30 INCHES
SPAN CLAMP MUST NEVER BE PLACE ON _____________.
LASHING WIRE; TO PREVENT DAMAGE, A CABLE GUARD MUST BE OVER CABLE
HOW MUCH CLIMBIMG SPACE FROM THE CENTER OF THE POLE MUST BE MAINTAINED AT ALL TIMES?
30 INCHES
WHEN ATTACHING THE DROP CABLE TO THE OPPOSITE SIDE OF THE POLE FROM THE TAP, A MINIMUM _______ DRIP LOOP HALF CIRCLE MUST BE LEFT FROM THE DROP CABLE GRIP TO THE STRAND.
5-INCH-DIAMETER
WHY SHOULD DROP CABLE NEVER BE TIED TO THE TOP SIDE OF THE STRAND OR POLE HARDWARE?
TO PREVENT SQUIRRELS CHEWING THE DROP
WHAT IS THE METHOD TO TIE OFF THE MESSENGER WIRE?
2-4-4
WHAT IS THE MINIMUM AMOUNT OF INCHES OF SAG FOR EVERY 50 FEET IN LENGTH IF THERE IS NO POWER REFERENCE?
6 INCHES
HOW SHOULD THE MID-SPAN ATTACHMENT BE INSTALLED?
FRIOM THE POLE TO THE MID-SPAN POINT AND THEN TO THE HOUSE
MULTI-SPAN CLAMP MUST ONLY BE ATTACHED TO THE _______.
STRAND
WHAT SHOULD BE PLACED BETWEEN THE DISTRIBUTION CABLE AND THE MULTI-SPAN CLAMP TO PREVENT CABLE DAMAGE?
CABLE GUARD
WHAT SHOULD BE PLACED ON EVERY DROP?
DROP ADDRESS AND SERVICE TAG
WHERE ARE TRAPS PROHIBITED FROM BEING PLACED AND WHY?
DIRECTLY ONTO THE TAP, BECAUSE IE MAY CAUSE PORT DAMAGE
WHEN PLACING A TRAP ON THE LINE YOU MAKE SURE MINIMUM _________ OF THE DROP IS MAINTAINED AT ALL TIMES.
BEND RADIUS
ALL UNDERGROUND DROPS MUST MEET THE MINIMUM REQUIREMENTS OF WHAT ARTICLE?
ARTICLE 820 OF THE NATIONAL ELECTRICAL CODE (NEC)
WHAT TYPE OF MATERIAL IS THE UNDERGROUND CABLE JACKET MADE OF?
POLYETHYLENE
WHAT LAWS SHOULD THE UNDERGROUND BORES BE IN COMPLIANCE WITH?
LOCAL, STATE, AND NATIONAL
WHAT IS THE MINIMUM BURY DEPTH FOR NEW INSTALLAION OF UNDERGROUND DROPS IN CONDUIT?
12 INCHES
FOR AN EXISTING INSTALLATION, AND WHEN NOT COMPLETELY IN CONDUIT, WHAT IS THE MINIMUM BURY DEPTH FOR UNDERGROUND DROP?
8 INCHES
WHERE SHOILD UNDERGROUND CABLE NEVER BE ROUTED?
ACROSS PROPERTY LINES, THROUGH THE LIDS OF THE PEDESTAL AND ANY GARDEN SPACE
HOW SHOULD UNDERGROUND DROPS BE ROUTED?
THE SHOREST ROUTE POSSIBLE
WHEN RUNNING UNDERGROUND DROPS PARALLEL TO LOT LINES, HOW MANY FEET AWAY FROM THE LINES BE ROUTED?
4 FEET
UNDERGROUND DROPS MUST EXTEND A MINIMUM OF _______ INCHES ABOVE TAP AND_________ INCHES PAST THE GROUNDBLOCK AT THE HOUSE.
12INCHES; 12INCHES