How do you control jet reaction |
Position on stable ground Start with pressure and flowrate that can be coped with and increase as and when needed Have minimum 2 people when on high flow rate and pressure Hose run out in straight line behind branch branch operator |
|
Mercury ground monitor operating ranges |
Raises/lowers 30-60 degrees Side movement 20 degrees either side of centre Nozzle can be lowered to 20 degrees if an operator stays with the unit |
|
When should a ground monitor be used |
Larger volume of water/foam is required than can be provided by hand branches Operation require extinguishing media to be thrown a greater distance Operations require extinguishing media over long period of time in same area of operations |
|
What is the flow rate and pressure of the hosereel |
Pressure - 30 bar preset, 42 bar max. Flowrates - 50, 100, 150, 230 |
|
Explain the pressure and flowrate of the RB101/Delta 400 |
Pressure - 6 bar optimum, 3 bar min, 7 bar max. Flowrate - 130, 230, 300, 400 |
|
Explain Projet 2 pressure and flowrate |
Pressure - 7 bar optimum, 3.5 bar minimum Flowrate at 7bar - Spray, 300 - Jet, 630 - Both, 930 Flowrate at 3.5bar - Spray, 200 - Jet, 400 - Both, 640 Has 57m throw |
|
What is hte flowrate and pressure of the mercury ground monitor |
Pressure - 7 bar, 3.5 bar minimum Flowrates - 950, 1400, 1900. Deluge 1750 |
|
What are the features of RB101 |
Flow rate control ring Pistol grip handle Stirrup handle on/off Pattern adjustment collar Spinning teeth at nozzle - 5 broken or 3 in a row is a defect Effective operation for pulse spray tech |